Shop by Instrument Type

Shop by Instrument Type

We use cookies 🍪
We use cookies and other similar technologies to improve your browsing experience and the functionality of our site. Learn more in our GDPR & Privacy Policy.

Tumescent Infiltration Angled Liposuction Cannula

A tumescent angled infiltration cannula is a blunt-tip cannula with a bend in the shaft, used to deliver tumescent or wetting solution into the subcutaneous plane before liposuction and body contouring. The angle lets the working section follow a curved body surface, so one entry port covers more area and the surgeon's wrist stays neutral through the pass. It belongs to the Healermed Liposuction Cannulas and Accessories range and is supplied in 11 hub and handle fittings and 84 diameter and length combinations, in bulk to distributors and hospital groups worldwide.

Surgeons also refer to these instruments as angled infiltrators, bent tumescent cannulas, curved infiltration cannulas, or angled wetting solution cannulas.

At a Glance

  • Instrument type: Angled tumescent infiltration cannula, reusable
  • Shaft: Angled — working section bent away from the hub axis
  • Tip: Closed blunt tip with side holes
  • Diameters: 1.0mm (19G) to 6.0mm (4G)
  • Working lengths: 3cm to 35cm
  • Fittings available: 11 hub and handle types
  • Material: German stainless steel
  • Sterilization: Steam autoclavable to 134°C
  • Custom sizes: Available on request
  • Manufacturer: Healermed Instruments, Sialkot, Pakistan

Angled German Stainless Steel Cannulas for Tumescent Infiltration

Tumescent infiltration decides how the rest of a liposuction case goes. Solution delivered evenly gives hemostasis, hydrodissection of the plane and anesthetic distribution across the treatment area. The obstacle on a curved region is geometry: a straight cannula either leaves the plane as the surface falls away, or forces the surgeon into a wrist position that cannot be held steadily. The angled shaft removes that trade-off.

What the Angle Does

An angled cannula has a bend in the shaft, so the working section travels at an angle to the hub axis instead of running straight back from it. That changes the direction of the pass itself, which is the difference between an angled cannula and a bayonet one: a bayonet steps the shaft sideways and then runs parallel again, while an angle redirects where the tip actually goes.

The practical gain is reach. The body is curved, and a straight cannula entering a flank, hip or submental area has to be forced to an awkward wrist position to stay in the subcutaneous plane as the surface falls away. An angled shaft follows that curve instead of fighting it, so a single entry port covers more area and the surgeon's wrist stays in a neutral position through the pass.

The second gain is clearance at the skin. Because the hub sits at an angle rather than flat against the surface, the syringe or handpiece is held up and away from the area being filled. The surgeon is not pressing on tissue that is in the middle of taking up solution, which makes it easier to read turgor as the endpoint approaches.

The distal tip is closed and rounded. It separates the subcutaneous plane by blunt dissection as the cannula advances, pushing vessels and nerves aside rather than dividing them, and side holes along the working section release the solution along the length of the pass rather than at one point.

Key Features

  • Angled shaft follows a curved body surface instead of fighting it
  • Wider coverage from one entry port with the wrist in a neutral position
  • Hub sits up and away from the skin, so the hand does not press on filling tissue
  • Closed blunt tip separates the plane without cutting vessels or nerves
  • 84 diameter and length combinations, from 1.0mm x 4cm to 6.0mm x 35cm
  • 11 hub and handle fittings covering syringe, pump tubing and power-assisted systems
  • Custom diameters, lengths, bend angles and hole patterns available on request

Available Fittings

Fitting Connects to
Luer Lock Standard Luer lock syringes and infiltration tubing
Stainless Steel Luer Lock Same as Luer lock, all-steel hub for heavy autoclave cycles
Super Luer Lock Luer connection with a larger bore, longer thread and heavier hub
Threaded Fitting Threaded reusable handles and tubing connectors
Fixed Power Handle Integrated handle, permanently attached to the shaft
Grooved Power Handle Grooved grip handle for controlled passes
Black Power Handle Black anodized handle, reduced glare under operating lights
Toomey Hub, 60cc 60cc Toomey-tip syringes, available from 2.0mm upward
MicroAire Compatible MicroAire PAL power-assisted handpieces
Lumsail Compatible Lumsail machine handpieces
Universal Luer Lock Luer lock hub built to fit across syringe brands

Specifications

Material German stainless steel
Shaft shape Angled — working section bent away from the hub axis
Tip Closed blunt tip with side holes
Diameters 1.0mm (19G), 1.1mm (19G), 1.2mm (18G), 1.4mm (17G), 1.5mm (17G), 1.6mm (16G), 1.8mm (15G), 2.0mm (14G), 2.4mm (13G), 2.5mm (13G), 3.0mm (11G), 3.5mm (10G), 4.0mm (8G), 4.5mm (7G), 5.0mm (6G), 6.0mm (4G)
Lengths 3, 4, 5, 7, 7.5, 8, 9, 10, 12, 14, 15, 20, 25, 30, 35cm (by diameter)
Fittings 11 hub and handle types
Reusable Yes — steam autoclavable to 134°C
Custom sizes Available on request
Compliance FDA CGMP, ISO 13485, ISO 9001, CE Mark

Clinical Applications

  • Tumescent infiltration of curved areas — flanks, hips, outer thighs
  • Submental and neck infiltration where the surface falls away sharply
  • Wetting solution delivery before power-assisted and syringe liposuction
  • Covering a wide field from a small number of entry ports

Material and Sterilization

The cannula is made from German stainless steel with a passivated surface that resists corrosion and pitting through repeated cleaning cycles. It is reusable and can be steam autoclaved at 134°C. Flush the lumen and every side hole with clean water immediately after use and dry fully before autoclaving. On an angled cannula, flush from both ends: any bend in a lumen is where residue settles first, and a partly blocked shaft changes how the solution distributes on the next case.

How to Choose

Diameter sets the flow rate and length sets the reach. For large body areas such as the abdomen, flanks and thighs, the 2.5mm to 4.0mm diameters in 25cm to 35cm are the usual working range, because they fill a large area in fewer passes. The 1.8mm to 2.5mm range in 15cm to 25cm suits arms, the neck and smaller regions, where the angle earns the most because the surface curves sharply. The 1.0mm to 1.5mm diameters in 5cm to 12cm are for facial and submental infiltration. Match the fitting to the syringe, pump or handpiece already in your theater.

Buying for your practice? Order online at factory-direct prices, straight from the manufacturer — no distributor markup.

Shop Online

Distributor, importer, or hospital group? Get bulk pricing, OEM manufacturing, and custom branding on the full cannula range.

Request Wholesale Price

Why Buy Direct From the Manufacturer

Manufactured by Healermed Instruments, a surgical instruments manufacturer and exporter based in Sialkot, Pakistan. Factory-direct pricing removes the importer and distributor layer. Production runs under an ISO 13485 and FDA CGMP quality system, with ISO 9001 and CE Mark certification. OEM manufacturing and custom branding are available for distributor and brand-owner orders.

Related Instruments

Choose the fitting that matches your equipment:

Frequently Asked Questions

What is an angled infiltration cannula used for?

It is used to deliver tumescent or wetting solution into the subcutaneous plane before liposuction and body contouring. The bend in the shaft lets the working section follow a curved body surface such as a flank or hip, so the cannula stays in the plane and one entry port covers more area.

What is the difference between an angled cannula and a straight cannula?

An angled cannula has a bend in the shaft, so the working section travels at an angle to the hub; a straight cannula runs in one line. The angle lets the cannula follow a curved body surface and stay in the subcutaneous plane without the surgeon twisting the wrist. A straight cannula is simpler to clean and store.

Is this cannula autoclavable?

Yes. The instrument is fully reusable and can be steam autoclaved at 134°C. Flush the lumen and every side hole with clean water immediately after use, remove all residue before sterilization, and dry completely. Flush from both ends so nothing is left sitting in the bend, where residue collects first.

What is the minimum order quantity for bulk orders?

The minimum order quantity is agreed per order rather than set at a fixed number. Send us the sizes, fittings and quantities you need through the wholesale request page and we will confirm the minimum for that specification. This lets a small distributor start with a trial order and a larger importer scale up on the same terms.

What is the difference between an angled cannula and a bayonet cannula?

An angled cannula bends once, so the working section travels in a different direction from the hub. A bayonet steps the shaft sideways and then runs parallel again, which moves the hand out of the sight line without changing where the tip goes. Choose angled for reach around a curved surface; choose bayonet for a clear view of the entry site.

Do you provide samples?

Yes. Samples are available on request and the buyer covers the shipping charges. Tell us the diameter, length and fitting you want to evaluate and we will confirm what can be sent. Testing a sample before a bulk order is the fastest way to check how the bend angle feels in the hand and to confirm hub fit with your own equipment.

Can I order a custom size?

Yes. Custom diameters, working lengths, bend angles and hole patterns are available on request in addition to the standard size grid. Send your specification through the wholesale request page and our production team will confirm what can be produced. Custom branding is also available for distributor and OEM orders.

Model: HM-ATC-LL Stock: In Stock
The Angled Tumescent Infiltration Cannula with Luer Lock fitting is a blunt-tip cannula with a bent working shaft, used to deliver tumescent or wettin..
$12.00
Add to Cart
Model: HM-ATC-SLL Stock: In Stock
The Angled Tumescent Infiltration Cannula with Super Luer Lock is a blunt-tip cannula with a bent working shaft, used to deliver tumescent or wetting ..
$15.00
Add to Cart
Model: HM-ATC-SSLL Stock: In Stock
The Angled Tumescent Infiltration Cannula with Stainless Steel Luer Lock is a blunt-tip cannula with a bent working shaft, used to deliver tumescent o..
$12.00
Add to Cart
Model: HM-ATC-TF Stock: In Stock
The Angled Tumescent Infiltration Cannula with Threaded Fitting is a blunt-tip cannula with a bent working shaft, used to deliver tumescent or wetting..
$15.00
Add to Cart
Model: HM-ATC-FPH Stock: In Stock
The Angled Tumescent Infiltration Cannula with Fixed Power Handle is a blunt-tip cannula with a bent working shaft and the handle permanently attached..
$20.00
Add to Cart
Model: HM-ATC-GPH Stock: In Stock
The Angled Tumescent Infiltration Cannula with Grooved Power Handle is a blunt-tip cannula with a bent working shaft and a machined grooved grip, used..
$20.00
Add to Cart
Model: HM-ATC-BPH Stock: In Stock
The Angled Tumescent Infiltration Cannula with Black Power Handle is a blunt-tip cannula with a bent working shaft and a black anodized handle, used t..
$20.00
Add to Cart
Model: HM-ATC-TH60 Stock: In Stock
The Angled Tumescent Infiltration Cannula with Toomey Hub is a blunt-tip cannula with a bent working shaft, built to fit 60cc Toomey-tip syringes. The..
$20.00
Add to Cart
Model: HM-ATC-MA Stock: In Stock
The MicroAire PAL Compatible Angled Tumescent Infiltration Cannula is a blunt-tip cannula with a bent working shaft and a hub built to fit MicroAire P..
$45.00
Add to Cart
Model: HM-ATC-LC Stock: In Stock
The Lumsail Compatible Angled Tumescent Infiltration Cannula is a blunt-tip cannula with a bent working shaft and a hub machined to fit Lumsail machin..
$15.00
Add to Cart
Model: HM-ATC-ULL Stock: In Stock
The Angled Tumescent Infiltration Cannula with Universal Luer Lock is a blunt-tip cannula with a bent working shaft, whose hub is machined to seat cor..
$8.00
Add to Cart
Showing 1 to 11 of 11 (1 Pages)
Healermed Support
Sales Agent · Online

Chat on WhatsApp
Only $650 to free shipping · $55 flat worldwide · Track order →