Shop by Instrument Type

Shop by Instrument Type

We use cookies 🍪
We use cookies and other similar technologies to improve your browsing experience and the functionality of our site. Learn more in our GDPR & Privacy Policy.

Stevens Style Liposuction Cannula – one Long Hole, Mercedes and 4 Round Ports

The Stevens Style Liposuction Cannula is a multi-port aspiration cannula used to remove subcutaneous fat under vacuum during liposuction and body contouring. Its defining feature is the port sequence along the shaft: one upper central long hole nearest the tip, then a Mercedes three-port group, then four round holes set in a line further back. It is used by plastic surgeons, aesthetic surgeons and body contouring clinics, and is supplied in bulk to distributors and hospital groups worldwide.

Surgeons also refer to this instrument as a Mercedes tip liposuction cannula, a multi-port suction cannula, or a multi-hole lipo cannula.

At a Glance

  • Instrument type: Multi-port liposuction aspiration cannula, reusable
  • Port pattern: One upper central long hole, then Mercedes group, then 4 in-line round holes
  • Tip: Blunt tip or bullet tip — both available
  • Diameters: 1.0mm (19G) to 6.0mm (4G)
  • Working lengths: 3cm to 35cm
  • Fittings available: 11 hub and handle types
  • Material: German stainless steel
  • Sterilization: Steam autoclavable to 134°C
  • Manufacturer: Healermed Instruments, Sialkot, Pakistan

Multi-Port Mercedes Tip Liposuction Cannula in German Stainless Steel

Port layout is what separates one aspiration cannula from another. A single-hole cannula draws fat from one point, so the surgeon must make more passes to clear an area evenly. The Stevens style spreads the aperture along the shaft instead, so each pass draws from a longer column of tissue and the removal is more even across the treated area.

How the Port Sequence Works

Reading from the tip backward, the first opening is a single long hole set on the upper surface. Because it is elongated rather than round, it draws along a continuous stretch of tissue instead of from one spot, which is what makes it useful at the leading edge of the pass where feathering and edge blending matter most. Behind it sits the Mercedes group, three ports arranged around the shaft, which is the pattern that carries most of the flow. Behind the Mercedes group, four round holes are set in a line along the shaft, extending the working aperture further back so the cannula keeps drawing throughout the stroke rather than only at the tip.

Blunt Tip or Bullet Tip

Both tip profiles are available on this cannula. The blunt tip is fully rounded and is the safer general-purpose choice, because it pushes vessels and nerves aside rather than dividing them. The bullet tip has a slightly tapered nose, which makes entry through fibrous or scarred tissue easier and needs less force on each pass. Select the tip profile when you order.

Key Features

  • Graduated port sequence — single upper long hole, Mercedes group, then 4 in-line round holes
  • Longer working aperture draws fat evenly across the whole stroke
  • Choice of blunt tip or bullet tip on any size
  • 84 diameter and length combinations, from 1.0mm x 4cm to 6.0mm x 35cm
  • 11 hub and handle fittings covering syringe, tubing and power-assisted systems
  • One-piece German stainless steel shaft, fully reusable
  • Custom diameters, lengths and port patterns available on request

Available Fittings

Fitting Connects to
Luer Lock Standard Luer lock syringes and suction tubing
Stainless Steel Luer Lock Same as Luer lock, all-steel hub for heavy autoclave cycles
Super Luer Lock Luer connection with a larger bore, longer thread and heavier hub
Threaded Fitting Threaded reusable handles and tubing connectors
Fixed Power Handle Integrated handle, permanently attached to the shaft
Grooved Power Handle Grooved grip handle for controlled passes
Black Power Handle Black anodized handle, reduced glare under operating lights
Toomey Hub, 60cc 60cc Toomey-tip syringes, available from 2.0mm upward
MicroAire Compatible MicroAire PAL power-assisted handpieces
Lums Compatible Lums machine handpieces
Universal Luer Lock Luer lock hub built to fit across syringe brands

Specifications

Material German stainless steel
Port pattern One upper central long hole, Mercedes group, 4 in-line round holes
Tip Blunt tip or bullet tip — select when ordering
Diameters 1.0mm (19G), 1.1mm (19G), 1.2mm (18G), 1.4mm (17G), 1.5mm (17G), 1.6mm (16G), 1.8mm (15G), 2.0mm (14G), 2.4mm (13G), 2.5mm (13G), 3.0mm (11G), 3.5mm (10G), 4.0mm (8G), 4.5mm (7G), 5.0mm (6G), 6.0mm (4G)
Lengths 3, 4, 5, 7, 7.5, 8, 9, 10, 12, 14, 15, 20, 25, 30, 35cm (by diameter)
Fittings 11 hub and handle types
Reusable Yes — steam autoclavable to 134°C
Custom sizes Available on request
Compliance FDA CGMP, ISO 13485, ISO 9001, CE Mark

Clinical Applications

  • Body contouring liposuction of the abdomen, flanks, back and thighs
  • Arm, submental and neck liposuction with the shorter, smaller-diameter sizes
  • Fat harvesting for grafting procedures
  • Revision and secondary liposuction in fibrous tissue, using the bullet tip profile

Material and Sterilization

Each cannula is made from German stainless steel with a smooth passivated surface that resists corrosion and pitting through repeated cleaning cycles. The cannulas are reusable and can be steam autoclaved at 134°C. Clean immediately after use, flush the lumen and every port, and dry fully before autoclaving. A multi-port cannula has more openings to clear than a single-hole design, so check each port under light before the instrument goes into the autoclave.

How to Choose

Diameter controls how fast fat is removed and how much contour irregularity is possible; length controls reach. Diameters of 3.0mm to 6.0mm in 25cm to 35cm are the working range for large body areas such as the abdomen, flanks and thighs. The 1.8mm to 2.5mm range in 15cm to 25cm suits arms, the neck and superficial refinement. The 1.0mm to 1.5mm diameters in 5cm to 12cm are for fine facial and submental work. Choose the blunt tip for general use and the bullet tip when passing through fibrous or previously operated tissue. Match the fitting to the equipment already in your theater.

Buying for your practice? Order online at factory-direct prices, straight from the manufacturer — no distributor markup.

Shop Online

Distributor, importer, or hospital group? Get bulk pricing, OEM manufacturing, and custom branding on the full cannula range.

Request Wholesale Price

Why Buy Direct From the Manufacturer

Manufactured by Healermed Instruments, a surgical instruments manufacturer and exporter based in Sialkot, Pakistan. You buy at factory prices with no importer or distributor layer in between. Production runs under an ISO 13485 and FDA CGMP quality system, with ISO 9001 and CE Mark certification. OEM manufacturing and custom branding are available for distributor and brand-owner orders.

Related Instruments

Choose the fitting that matches your equipment:

Frequently Asked Questions

What is a Stevens style liposuction cannula used for?

It is used to remove subcutaneous fat under vacuum during liposuction and body contouring. The port sequence runs from a single long hole on the upper surface near the tip, through a Mercedes three-port group, to four round holes in a line further back, so the cannula draws fat along the length of each pass rather than from a single point.

What is the difference between a Mercedes tip cannula and a single-hole cannula?

A Mercedes tip has three ports grouped around the shaft; a single-hole cannula has one. The three-port group moves more fat per pass and spreads the draw around the shaft, which reduces the chance of over-resection at one point. A single hole gives finer, slower control and is usually chosen for superficial refinement.

Should I choose a blunt tip or a bullet tip?

Choose the blunt tip for general liposuction. Its fully rounded nose pushes vessels and nerves aside rather than dividing them, which is the safer default. Choose the bullet tip when working through fibrous, scarred or previously operated tissue, where the tapered nose needs less force on each pass. Both profiles are available in every size.

Is this liposuction cannula autoclavable?

Yes. All Healermed liposuction cannulas are reusable and can be steam autoclaved at 134°C. Flush the lumen and every port with clean water immediately after use, remove all residue before sterilization, and dry the cannula fully. Check each of the eight openings under light, because a multi-port cannula holds residue in more places than a single-hole design.

What is the minimum order quantity for bulk orders?

The minimum order quantity is agreed per order rather than set at a fixed number. Send us the sizes, tips, fittings and quantities you need through the wholesale request page and we will confirm the minimum for that specification. This lets a small distributor start with a trial order and a larger importer scale up on the same terms.

Do you provide samples?

Yes. Samples are available on request and the buyer covers the shipping charges. Tell us the diameter, length, tip profile and fitting you want to evaluate and we will confirm what can be sent. Testing a sample before a bulk order is the fastest way to check port finish, edge deburring and hub fit against your own equipment.

Model: HM-SLC-LL Stock: In Stock
The Stevens Style Liposuction Cannula with Luer Lock fitting is a multi-port aspiration cannula used to remove subcutaneous fat under vacuum during li..
$12.00
Add to Cart
Model: HM-SLC-SLL Stock: In Stock
The Stevens Style Liposuction Cannula with Super Luer Lock is a multi-port aspiration cannula used to remove subcutaneous fat under vacuum during lipo..
$15.00
Add to Cart
Model: HM-SLC-SSLL Stock: In Stock
The Stevens Style Liposuction Cannula with Stainless Steel Luer Lock is a multi-port aspiration cannula used to remove subcutaneous fat under vacuum d..
$12.00
Add to Cart
Model: HM-SLC-TF Stock: In Stock
The Stevens Style Liposuction Cannula with Threaded Fitting is a multi-port aspiration cannula used to remove subcutaneous fat under vacuum during lip..
$15.00
Add to Cart
Model: HM-SLC-FPH Stock: In Stock
The Stevens Style Liposuction Cannula with Fixed Power Handle is a multi-port aspiration cannula supplied with the handle permanently attached to the ..
$20.00
Add to Cart
Model: HM-SLC-GPH Stock: In Stock
The Stevens Style Liposuction Cannula with Grooved Power Handle is a multi-port aspiration cannula fitted with a machined grooved grip, used to remove..
$20.00
Add to Cart
Model: HM-SLC-BPH Stock: In Stock
The Stevens Style Liposuction Cannula with Black Power Handle is a multi-port aspiration cannula fitted with a black anodized handle, used to remove s..
$20.00
Add to Cart
Model: HM-SLC-TH60 Stock: In Stock
The Stevens Style Liposuction Cannula with Toomey Hub is a multi-port aspiration cannula built to fit 60cc Toomey-tip syringes, used for syringe-assis..
$20.00
Add to Cart
Model: HM-SLC-MA Stock: In Stock
The MicroAire PAL Compatible Stevens Style Liposuction Cannula is a multi-port aspiration cannula with a hub built to fit MicroAire PAL power-assisted..
$45.00
Add to Cart
Model: HM-SLC-LC Stock: In Stock
The Lums Compatible Stevens Style Liposuction Cannula is a multi-port aspiration cannula with a hub machined to fit Lums machine handpieces, used to r..
$15.00
Add to Cart
Model: HM-SLC-ULL Stock: In Stock
The Stevens Style Liposuction Cannula with Universal Luer Lock is a multi-port aspiration cannula whose hub is machined to seat correctly across the r..
$8.00
Add to Cart
Showing 1 to 11 of 11 (1 Pages)
Healermed Support
Sales Agent · Online

Chat on WhatsApp
Only $650 to free shipping · $55 flat worldwide · Track order →