Shop by Instrument Type

Shop by Instrument Type

We use cookies 🍪
We use cookies and other similar technologies to improve your browsing experience and the functionality of our site. Learn more in our GDPR & Privacy Policy.

Flap Dissector Liposuction Cannulas

Related Instruments

Liposuction Cannulas and AccessoriesFlap Dissector Liposuction Cannulas

A flap dissector liposuction cannula is a solid-shaft dissecting instrument with a broad flattened blunt head, used to raise and separate tissue flaps and planes during body contouring, liposuction and reconstructive work. The flat head opens a plane across its full width in one sweep rather than along a narrow line. This category is part of the Healermed Liposuction Cannulas and Accessories range and covers 13 hub and handle fittings.

At a Glance

  • Instrument type: Flap dissector cannula for tissue plane dissection, reusable
  • Openings: No aspiration ports — solid shaft behind the dissecting head
  • Tip: Flattened spatula dissecting head
  • Diameters: 1.0mm (19G), 1.1mm (19G), 1.2mm (18G), 1.4mm (17G), 1.5mm (17G), 1.6mm (16G), 1.8mm (15G), 2.0mm (14G), 2.4mm (13G), 2.5mm (13G), 3.0mm (11G), 3.5mm (10G), 4.0mm (8G), 4.5mm (7G), 5.0mm (6G), 6.0mm (4G)
  • Working lengths: 3, 4, 5, 7, 7.5, 8, 9, 10, 12, 14, 15, 20, 25, 30, 35cm (by diameter)
  • Fittings: 13 hub and handle types
  • Material: German stainless steel
  • Sterilization: Steam autoclavable to 134°C
  • Manufacturer: Healermed Instruments, Sialkot, Pakistan

Flap Dissector Liposuction Cannulas in German Stainless Steel

Raising a wide plane with a round cannula means many narrow parallel passes, and the joins between them are where irregularity begins. A flattened head opens the plane across its whole width at once, which is why flap work uses a different instrument from aspiration.

What a Flap Dissector Does

A flap dissector raises tissue planes. The working end is flattened into a broad, blunt spatula rather than drawn to a point or a V, and the shaft behind it is solid: there are no ports and nothing is aspirated through this instrument.

The flat head is the whole design. A round cannula separates tissue along a narrow line, so raising a wide plane with one means many parallel passes that have to be joined up afterwards, and the joins are where irregularity comes from. A broad flat head opens the plane across its full width in a single sweep, so the flap lifts evenly and at one consistent depth.

Depth control is the second gain. A flat head naturally follows the plane it is in, because the wide face resists tipping up or down in a way a round shaft does not. The surgeon sets the level once and the instrument tends to hold it, which matters when the flap being raised is thin and the layer above it has to survive.

It is blunt on every surface. It separates by spreading and lifting, pushing perforators, nerves and fibrous attachments aside rather than dividing them, which is what allows it to be used under a flap where a sharpened instrument would risk the blood supply. Where an attachment will not yield, it is released deliberately with a sharp dissector rather than forced with this one.

Choose Your Fitting

All 13 fittings carry the same shaft and tip. Pick the one that matches the equipment already in your theater.

Luer Lock
Standard Luer lock syringes and suction tubing
Stainless Steel Luer Lock
All-steel hub for heavy autoclave cycles
Super Luer Lock
Larger bore, longer thread, heavier hub
Threaded Fitting
Threaded reusable handles and tubing connectors
Fixed Power Handle
Integrated handle, permanently attached
Grooved Power Handle
Grooved grip for wet-glove control
Black Power Handle
Black anodized, low glare under lights
Toomey Hub 60cc
60cc Toomey-tip syringes, from 2.0mm up
MicroAire PAL Compatible
MicroAire PAL power-assisted handpieces
Lumsail Compatible
Lumsail machine handpieces
Universal Luer Lock
Fits Luer lock across syringe brands
Vibrasat Quick Lock
Vibrasat quarter-turn quick-lock coupling
BeautiFill Laser Compatible
BeautiFill laser lipolysis handpieces

For the full range on one page, see the main Flap Dissector Liposuction Cannula product page.

Specifications

MaterialGerman stainless steel
OpeningsNo aspiration ports — solid shaft behind the dissecting head
TipFlattened spatula dissecting head
Diameters1.0mm (19G), 1.1mm (19G), 1.2mm (18G), 1.4mm (17G), 1.5mm (17G), 1.6mm (16G), 1.8mm (15G), 2.0mm (14G), 2.4mm (13G), 2.5mm (13G), 3.0mm (11G), 3.5mm (10G), 4.0mm (8G), 4.5mm (7G), 5.0mm (6G), 6.0mm (4G)
Lengths3, 4, 5, 7, 7.5, 8, 9, 10, 12, 14, 15, 20, 25, 30, 35cm (by diameter)
ReusableYes — steam autoclavable to 134°C
Custom sizesAvailable on request
ComplianceFDA CGMP, ISO 13485, ISO 9001, CE Mark

Clinical Applications

  • Raising and separating tissue flaps during body contouring
  • Opening wide planes before liposuction or fat grafting
  • Undermining in abdominoplasty and body lift procedures
  • Facial and neck plane dissection with the smaller head widths

How to Choose a Size

Head width and shaft length matter more than diameter on this instrument, because the head sets how much plane each sweep opens. Wider heads on the 3.0mm to 4.0mm shafts in 25cm to 35cm suit abdominal and body flap work, where the plane is large and the reach is long. Narrower heads on the 2.0mm to 2.5mm shafts in 15cm to 25cm suit the face, neck and arms. Tell us the plane you are raising and we will confirm the head width that fits it.

Material and Sterilization

The instrument is made from German stainless steel with a passivated surface that resists corrosion and pitting through repeated cleaning cycles. It is reusable and can be steam autoclaved at 134°C. Clean immediately after use and dry fully before autoclaving. A flat head has no lumen but its faces and edges trap tissue against the shaft junction, so brush that junction specifically and inspect the whole head under light at every cycle. Sight along the head to confirm it has not been bent, since a distorted head no longer follows a plane evenly and cannot be corrected on a reusable instrument.

Buying for your practice? Order online at factory-direct prices, straight from the manufacturer — no distributor markup.

Shop Flap Dissector Liposuction Cannulas

Distributor, importer, or hospital group? Get bulk pricing, OEM manufacturing, and custom branding on the full range.

Request Wholesale Price

Why Buy Direct From the Manufacturer

Manufactured by Healermed Instruments, a surgical instruments manufacturer and exporter based in Sialkot, Pakistan. Factory-direct pricing removes the importer and distributor layer. Production runs under an ISO 13485 and FDA CGMP quality system, with ISO 9001 and CE Mark certification. OEM manufacturing and custom branding are available for distributor and brand-owner orders.

More Liposuction Cannulas and Accessories

Flap Dissector Liposuction Cannula
All 13 fittings on one product page
Liposuction Cannulas
Every cannula type and port pattern we make
Liposuction Accessories
Handles, hubs and cannulas for liposuction

Frequently Asked Questions

What is a flap dissector liposuction cannula used for?

It is used to raise and separate tissue flaps and planes during body contouring, liposuction and reconstructive procedures. The broad flattened blunt head opens the plane across its full width as it sweeps, lifting the flap evenly at one depth while pushing perforators and fibrous attachments aside rather than dividing them.

What is the difference between a flap dissector and a V-dissector?

A V-dissector has a narrow V tip that splits tissue along a line and travels between the halves, which suits pre-tunnelling a route. A flap dissector has a broad flattened head that opens a plane across its full width in one sweep, which suits raising a flap evenly. Both are blunt; they open different shapes of space.

Is this instrument autoclavable?

Yes. It is fully reusable and can be steam autoclaved at 134°C. Clean immediately after use, remove all residue before sterilization, and dry completely.

Which size should I use?

Wider heads on 3.0mm to 4.0mm shafts in 25cm to 35cm suit abdominal and body flap work where the plane is large and the reach is long. Narrower heads on 2.0mm to 2.5mm shafts in 15cm to 25cm suit the face, neck and arms. Head width matters more than shaft diameter here, since the head sets how much plane each sweep opens.

What is the minimum order quantity for bulk orders?

The minimum order quantity is agreed per order rather than set at a fixed number. Send us the sizes, fittings and quantities you need through the wholesale request page and we will confirm the minimum for that specification.

Do you provide samples?

Yes. Samples are available on request and the buyer covers the shipping charges. Tell us the diameter, length and fitting you want to evaluate and we will confirm what can be sent.

Can I order a custom size?

Yes. Custom diameters, working lengths and configurations are available on request in addition to the standard size grid. Send your specification through the wholesale request page and our production team will confirm what can be produced.

Model: HM-FLD-LL Stock: In Stock
Liposuction Cannulas and Accessories › Flap Dissector Liposuction Cannulas › Flap Dissector Liposuction Cannula – Luer Lock The Flap ..
$12.00
Add to Cart
Model: HM-FLD-SSLL Stock: In Stock
Liposuction Cannulas and Accessories › Flap Dissector Liposuction Cannulas › Flap Dissector Liposuction Cannula – Stainless Steel Luer L..
$12.00
Add to Cart
Model: HM-FLD-SLL Stock: In Stock
Liposuction Cannulas and Accessories › Flap Dissector Liposuction Cannulas › Flap Dissector Liposuction Cannula – Super Luer Lock The..
$15.00
Add to Cart
Model: HM-FLD-TF Stock: In Stock
Liposuction Cannulas and Accessories › Flap Dissector Liposuction Cannulas › Flap Dissector Liposuction Cannula – Threaded Fitting Th..
$15.00
Add to Cart
Model: HM-FLD-FPH Stock: In Stock
Liposuction Cannulas and Accessories › Flap Dissector Liposuction Cannulas › Flap Dissector Liposuction Cannula – Fixed Power Handle ..
$25.00
Add to Cart
Model: HM-FLD-GPH Stock: In Stock
Liposuction Cannulas and Accessories › Flap Dissector Liposuction Cannulas › Flap Dissector Liposuction Cannula – Grooved Power Handle The Flap Dis..
$25.00
Add to Cart
Model: HM-FLD-BPH Stock: In Stock
Liposuction Cannulas and Accessories › Flap Dissector Liposuction Cannulas › Flap Dissector Liposuction Cannula – Black Power Handle ..
$25.00
Add to Cart
Model: HM-FLD-TH60 Stock: In Stock
Liposuction Cannulas and Accessories › Flap Dissector Liposuction Cannulas › Flap Dissector Liposuction Cannula – Toomey Hub 60cc The..
$20.00
Add to Cart
Model: HM-FLD-LC Stock: In Stock
Liposuction Cannulas and Accessories › Flap Dissector Liposuction Cannulas › Flap Dissector Liposuction Cannula – Lumsail Compatible ..
$15.00
Add to Cart
Model: HM-FLD-MA Stock: In Stock
Liposuction Cannulas and Accessories › Flap Dissector Liposuction Cannulas › Flap Dissector Liposuction Cannula – MicroAire PAL Compatible The Flap..
$45.00
Add to Cart
Model: HM-FLD-ULL Stock: In Stock
Liposuction Cannulas and Accessories › Flap Dissector Liposuction Cannulas › Flap Dissector Liposuction Cannula – Universal Luer Lock ..
$8.00
Add to Cart
Model: HM-FLD-BFL Stock: In Stock
Liposuction Cannulas and Accessories › Flap Dissector Liposuction Cannulas › Flap Dissector Liposuction Cannula – BeautiFill Laser Compatible The F..
$15.00
Add to Cart
Model: HM-FLD-VQL Stock: In Stock
Liposuction Cannulas and Accessories › Flap Dissector Liposuction Cannulas › Flap Dissector Liposuction Cannula – Vibrasat Quick Lock The Flap Diss..
$35.00
Add to Cart
Showing 1 to 13 of 13 (1 Pages)
Healermed Support
Sales Agent · Online

Chat on WhatsApp
Only $650 to free shipping · $55 flat worldwide · Track order →