Buy Online
Add to Cart Now
Your shopping cart is empty!
Lorem Ipsum is simply dummy text of the printing and typesetting industry.
Globally certified & registered manufacturer
Globally trusted & secured payment methods
The Stevens Style Liposuction Cannula with Toomey Hub is a multi-port aspiration cannula built to fit 60cc Toomey-tip syringes, used for syringe-assisted liposuction and fat harvesting. The Toomey hub has a wide, non-Luer opening, so aspirated fat moves through it without the resistance a narrow Luer taper creates. This fitting is made from 2.0mm (14G) upward. It is used by plastic surgeons doing fat transfer and supplied in bulk to distributors worldwide. See the full Stevens Style Liposuction Cannula range for other fittings.
Buyers also search for this instrument as a 60cc Toomey lipo cannula, a fat harvesting cannula, or a syringe liposuction cannula.
At a Glance
A Toomey tip is a wide-bore syringe fitting, not a Luer taper. It exists because aspirated fat is thick and moves slowly through a narrow connector. A cannula built with a matching Toomey hub keeps the whole path wide, so the working limit is the cannula diameter and port size rather than the connector.
Reading from the tip backward, the first opening is a single long hole on the upper surface. Being elongated rather than round, it draws along a continuous stretch of tissue instead of from one spot, which is what makes it useful at the leading edge of the pass where feathering matters most. Behind it sits the Mercedes group, three ports arranged around the shaft, which carries most of the flow. Behind that, four round holes are set in a line along the shaft, extending the working aperture so the cannula keeps drawing throughout the stroke instead of only at the tip.
Both tip profiles are available on this cannula. The blunt tip is fully rounded and is the safer general-purpose choice, because it pushes vessels and nerves aside rather than dividing them. The bullet tip has a slightly tapered nose, which makes entry through fibrous or scarred tissue easier and needs less force on each pass. Select the tip profile when you order.
| Material | German stainless steel |
| Fitting | Toomey hub, 60cc syringes |
| Port pattern | One upper central long hole, Mercedes group, 4 in-line round holes |
| Tip | Blunt tip or bullet tip — select when ordering |
| Diameters | 2.0mm (14G), 2.4mm (13G), 2.5mm (13G), 3.0mm (11G), 3.5mm (10G), 4.0mm (8G), 4.5mm (7G), 5.0mm (6G), 6.0mm (4G) |
| Lengths | 3, 5, 7, 10, 12, 14, 15, 20, 25, 30, 35cm (by diameter) |
| Reusable | Yes — steam autoclavable to 134°C |
| Custom sizes | Available on request |
| Compliance | FDA CGMP, ISO 13485, ISO 9001, CE Mark |
The cannula is made from German stainless steel with a passivated surface that resists corrosion through repeated autoclave cycles. It is reusable and can be steam sterilized at 134°C. Flush the lumen and every port with clean water immediately after use and dry fully before autoclaving. A multi-port cannula has more openings to clear than a single-hole design, so check each port under light before sterilization.
The Toomey fitting starts at 2.0mm, so for finer facial work below 2.0mm choose the Luer lock version instead. Within the Toomey range, 2.0mm to 2.5mm in 15cm to 25cm suits arms, neck and superficial refinement, while 3.0mm to 6.0mm in 25cm to 35cm is for large body areas. Choose the blunt tip for general use and the bullet tip for fibrous or previously operated tissue.
Buying for your practice? Order online at factory-direct prices, straight from the manufacturer — no distributor markup.
Distributor, importer, or hospital group? Get bulk pricing, OEM manufacturing, and custom branding on the full cannula range.
Manufactured by Healermed Instruments, a surgical instruments manufacturer and exporter based in Sialkot, Pakistan. Factory-direct pricing removes the importer and distributor layer. Production runs under an ISO 13485 and FDA CGMP quality system, with ISO 9001 and CE Mark certification. OEM manufacturing and custom branding are available for distributor and brand-owner orders.
Other fittings in the same cannula range:
What is a Toomey hub liposuction cannula used for?
It is used with 60cc Toomey-tip syringes for syringe-assisted liposuction and fat harvesting. The wide non-Luer hub keeps aspirated fat moving instead of clogging at a narrow connector, and the multi-port sequence draws along the length of each pass rather than at one point.
What is the difference between a Mercedes tip cannula and a single-hole cannula?
A Mercedes tip has three ports grouped around the shaft; a single-hole cannula has one. The three-port group moves more fat per pass and spreads the draw around the shaft, which reduces the chance of over-resection at one point. A single hole gives finer, slower control and is usually chosen for superficial refinement.
Should I choose a blunt tip or a bullet tip?
Choose the blunt tip for general liposuction. Its fully rounded nose pushes vessels and nerves aside rather than dividing them, which is the safer default. Choose the bullet tip when working through fibrous, scarred or previously operated tissue, where the tapered nose needs less force on each pass. Both profiles are available in every size.
Is this cannula autoclavable?
Yes. The instrument is fully reusable and can be steam autoclaved at 134°C. Flush the lumen and every port with clean water immediately after use, remove all residue before sterilization, and dry completely. Check each of the eight openings under light, because a multi-port cannula holds residue in more places than a single-hole design.
What is the minimum order quantity for bulk orders?
The minimum order quantity is agreed per order rather than set at a fixed number. Send us the sizes, tips and quantities you need through the wholesale request page and we will confirm the minimum for that specification. This lets a small distributor start with a trial order and a larger importer scale up on the same terms.
Do you provide samples?
Yes. Samples are available on request and the buyer covers the shipping charges. Tell us the diameter, length and tip profile you want to evaluate and we will confirm what can be sent. Testing a sample first confirms the hub seats correctly on the 60cc syringes you already stock.
Can I order a custom size?
Yes. Custom diameters, working lengths, and port patterns are available on request in addition to the standard size grid. Send your specification through the wholesale request page and our production team will confirm what can be produced. Custom branding is also available for distributor and OEM orders.