Liposuction Cannulas and Accessories › Luer Lock to Luer Lock Fat Transfer 2mm The Luer Lock to Luer Lock Fat Transfer 2mm is a female-to-female connector that joins two syringes for closed-system fat transfer. The 2.0mm bore moves graft between s... Read More
$9.00
Direct Manufacturer B2B / OEM

Buy Online

Add to Cart Now

Bulk & Wholesale

Volume pricing & private label

Factory Quote

Logo & Name Engraving

FREE

Add your logo or name in checkout notes

Guide

Custom Sizes

Any length, curvature, or modification — to your spec

Request

Certified Quality

Globally certified & registered manufacturer

  • FDA · cGMPUS Registered & GMP Compliant
  • CE MarkingEU MDR Compliant
  • ISO 13485Medical Devices QMS
  • ISO 9001Quality Management
  • EUDAMEDEU Registered
SSL SECURED

Your Security, Our Priority

Globally trusted & secured payment methods

  • PayPal
  • Visa / Mastercard
  • Apple Pay
  • Google Pay
  • Bank transfer

Liposuction Cannulas and Accessories › Luer Lock to Luer Lock Fat Transfer 2mm

The Luer Lock to Luer Lock Fat Transfer 2mm is a female-to-female connector that joins two syringes for closed-system fat transfer. The 2.0mm bore moves graft between syringes with low mechanical stress, so it is used to combine harvest volumes and load injection syringes rather than to emulsify. It is part of the Healermed liposuction cannulas and accessories range.

At a Glance

  • Item type: Syringe-to-syringe fat transfer connector, reusable
  • Bore: 2.0mm
  • Connection: Luer lock both ends, female to female
  • Action: Low-shear transfer — moves graft rather than emulsifying it
  • System: Closed path, no decanting and no exposure to room air
  • Material: German stainless steel
  • Sterilization: Steam autoclavable to 134°C
  • Manufacturer: Healermed Instruments, Sialkot, Pakistan

Luer Lock to Luer Lock Fat Transfer 2mm in German Stainless Steel

Most of what happens to a graft between harvest and injection is transfer, not processing. This connector is built for that part: moving fat from one syringe to another without decanting it and without changing it more than the move requires.

What a Luer Lock to Luer Lock Transfer Connector Does

It joins two syringes barrel to barrel. Both ends are Luer lock, so a filled syringe screws onto one side and an empty one onto the other, and the graft is driven between them through the bore in the middle.

Two things happen in that bore. The graft moves from one syringe to the other without being decanted, and it is sheared by the channel it passes through. The first is why the connector exists at all: transferring by pouring into a bowl and drawing back up exposes living tissue to room air and adds handling steps, where a screwed connection keeps the graft in a closed path from harvest to injection.

The second is why the bore size is on the label. A narrow channel breaks fat parcels down quickly and produces an emulsion; a wide one moves the same graft with its structure largely intact. At 2.0mm this connector sits deliberately toward the gentle end: it transfers, combines and loads syringes with modest mechanical stress, rather than emulsifying.

That makes it the general-purpose connector on a fat grafting table. Consolidating several harvest syringes into one, moving graft to smaller syringes for injection, and passing fat through a filter or a processing step are all transfers where the aim is to move the tissue, not to change it.

Where 2.0mm Sits in the Range

Bore size is what decides whether a transfer preserves the graft or reshapes it. The 2.0mm connector is a transfer tool rather than an emulsifier.

Below 1.5mm
High shear. Used to emulsify fat toward a nanofat consistency in a small number of passes.
1.5mm to 1.8mm
Moderate shear. Produces a microfat grade that keeps more structure than an emulsion.
2.0mm — this connector
Low shear. Moves graft between syringes, combines harvest volumes and loads injection syringes with minimal change to the tissue.
2.4mm and above
Lowest shear. For structural graft where parcels must stay as intact as possible.

Key Features

  • ✔ Luer lock both ends, female to female, for standard grafting syringes
  • ✔ 2.0mm bore transfers graft with low mechanical stress rather than emulsifying it
  • ✔ Closed path — no decanting into a bowl and no exposure to room air
  • ✔ Combines several harvest syringes into one and loads smaller injection syringes
  • ✔ One-piece German stainless steel, fully reusable and autoclavable
  • ✔ Other bore sizes available in the anaerobic adapter range

Specifications

MaterialGerman stainless steel
Bore2.0mm
ConnectionLuer lock both ends, female to female
FunctionLow-shear syringe-to-syringe transfer
ReusableYes — steam autoclavable to 134°C
Other bores1.0mm to 3.0mm available in the anaerobic adapter range
ComplianceFDA CGMP, ISO 13485, ISO 9001, CE Mark

Clinical Applications

  • Combining several harvest syringes into one before processing
  • Loading smaller syringes for injection from a larger harvest syringe
  • Moving graft through a processing step without decanting it
  • Structural and microfat grafting where parcels should stay largely intact

Material and Sterilization

The connector is made from German stainless steel and is fully reusable, steam autoclavable to 134°C. Flush the bore from both ends immediately after every case, before residue sets, and hold it to the light to confirm the channel is clear end to end. A partly blocked bore behaves like a narrower one: it raises the force needed on the plunger and shears the graft more than the 2.0mm rating suggests, with nothing visible to warn the surgeon. Check both Luer threads at every cycle, since a worn thread leaks under the pressure a syringe plunger generates.

Distributor, importer, or hospital group? Get bulk pricing, OEM manufacturing, and custom branding on the full range.

Request Wholesale Price

Why Buy Direct From the Manufacturer

Manufactured by Healermed Instruments, a surgical instruments manufacturer and exporter based in Sialkot, Pakistan. Factory-direct pricing removes the importer and distributor layer. Production runs under an ISO 13485 and FDA CGMP quality system, with ISO 9001 and CE Mark certification. OEM manufacturing and custom branding are available for distributor and brand-owner orders.

Related Fat Transfer Items

Anaerobic Fat Transfer Adapters
Seven bores from 1.0mm to 3.0mm, for emulsifying rather than transferring.
Mesh Filters for Nano Fat Transfer
Seven grades from 0.2mm to 0.8mm, setting particle size after emulsification.
Nano Fat Transfer Set – Long Pattern
Complete set for preparing nanofat, supplied with mesh filters and gas rings.

Frequently Asked Questions

What is a Luer lock to Luer lock fat transfer connector used for?

It joins two syringes barrel to barrel so graft can be moved from one to the other without decanting. It is used to combine several harvest syringes into one, to load smaller syringes for injection, and to move fat through a processing step while keeping it in a closed path.

Does the 2.0mm bore emulsify the fat?

Not meaningfully. At 2.0mm the shear is low, which is the point: this connector is for moving graft while leaving its structure largely intact. To emulsify toward a microfat or nanofat grade, use a narrower bore from the anaerobic adapter range.

What is the difference between this and the anaerobic adapters?

Both are closed-path syringe-to-syringe connectors. This is a single fixed 2.0mm bore chosen for low-shear transfer. The anaerobic adapter range covers seven bores from 1.0mm to 3.0mm so the surgeon can select how much the graft is sheared, including bores narrow enough to emulsify.

Is it reusable?

Yes. It is German stainless steel and steam autoclavable to 134°C. Flush the bore from both ends immediately after every case and hold it to the light to confirm the channel is clear, since a partly blocked bore shears the graft more than its stated size.

What is the minimum order quantity for bulk orders?

The minimum order quantity is agreed per order rather than set at a fixed number. Send us the quantities and any custom bore or branding requirements through the wholesale request page and we will confirm the minimum for that specification.

Brand: Healermed instruments Model: HM-VDT-BFL
Liposuction Cannulas and Accessories › Toledo V-Dissector Liposuction Cannulas › Toledo V-Dissector Liposuction Cannula – BeautiFill Las..
$15.00
Add to Cart
Brand: Healermed instruments Model: HM-JSH-5MM
The Joseph skin hook double prong 5mm is a handheld retractor used for atraumatic skin edge elevation and exposure during plastic and reconstructive s..
$8.00
Add to Cart
Brand: Healermed instruments Model: HM-2HI-SSLL
Liposuction Cannulas and Accessories › Two Holes In Line Injector Cannulas › Two Holes In Line Injector Cannula – Stainless Steel Luer L..
$12.00
Add to Cart
Brand: Healermed instruments Model: HM-MSH-BS
Liposuction Cannulas and Accessories › Multiport Speed Harvester Both End Sharp Liposuction Cannulas › Multiport Speed Harvester Both End Sharp Liposu..
$12.00
Add to Cart
Brand: Healermed instruments Model: HM-FIC
The Facelift Infiltration Cannula is a blunt-tip, side-ported cannula used to deliver tumescent or wetting solution into the subcutaneous plane of the..
$12.00
Add to Cart
Brand: Healermed instruments Model: HM-FIC-BFL
Liposuction Cannulas and Accessories › Facelift Infiltration Liposuction Cannulas › BeautiFill Laser Compatible The Facelift Infiltra..
$15.00
Add to Cart
Brand: Healermed instruments Model: HM-ESC-C
Spare Schimmelbusch Cannula Conical Type: conical (tapered) tip, stainless steel, reusable. This Schimmelbusch cannula is a spare ear syringe cannula ..
$6.00
Add to Cart
Brand: Healermed instruments Model: ENT-MN4-11
The Myles Nasal Punch Through-Cutting Forceps Size #4 are elite-tier, premium OR-grade ENT instruments engineered for precise tissue excision during r..
$35.00
Add to Cart