Buy Online
Add to Cart Now
Your shopping cart is empty!
Lorem Ipsum is simply dummy text of the printing and typesetting industry.
Globally certified & registered manufacturer
Globally trusted & secured payment methods
Liposuction Cannulas and Accessories › Complete Sets for Liposuction Cannulas › Fat Transfer Set for Face
A complete face fat transfer set: infiltration, harvesting, three injection calibres and the processing accessories, in the sizes a facial case actually uses. Every cannula is Super Luer Lock, so the whole set runs on one connection standard with no adapters. Quantity is one of each item.
At a Glance
A facial fat transfer is a sequence, and every step needs a different instrument. Infiltrate, harvest, separate, load, inject. Buy them individually and something is always missing at the moment it is needed.
The choices in this set follow the anatomy. Infiltration and harvesting are done at 2.0mm and 2.5mm, which is enough to work a small donor area without taking the parcels apart. Injection is done at three calibres — 0.7mm, 0.9mm and 1.2mm — because a face is not one plane. The 0.7mm at 4.5cm reaches the thinnest periorbital tissue; the 1.2mm at 7.5cm places volume along the cheek and jawline. Carrying only one of them means placing the wrong grade of thread in one of those areas.
The accessories are in the set because the graft is worth nothing without them. A decant stand separates tumescent fluid from the graft before it is placed, and stop locks hold vacuum during harvesting so the surgeon is not maintaining suction by hand through the whole donor site.
One of each item. Every cannula is Super Luer Lock, so the whole set runs on one connection standard.
| Item | Qty |
| Infiltrator Cannula, Straight, SUPOR Luer Lock, 2.0 mm × 20 cm Delivers tumescent fluid evenly through the donor site before harvesting. |
1 |
| Multi-Hole Harvester Cannula with Beveled Tip, 2.5 mm × 20 cm Beveled ports lead tissue in rather than cutting it, so parcels meet less shearing on collection. |
1 |
| Blunt Tip Small Single-Hole Injecting Cannula, SUPOR Luer-Lock, 0.7 mm × 4.5 cm Finest calibre in the set, for the thinnest periorbital tissue. |
1 |
| Blunt Tip Small Single-Hole Injecting Cannula, SUPOR Luer-Lock, 0.9 mm × 5.5 cm Mid calibre, for temple, tear trough and fine facial layering. |
1 |
| Blunt Tip Small Single-Hole Injecting Cannula, SUPOR Luer-Lock, 1.2 mm × 7.5 cm Largest injection calibre in the set, for cheek and jawline volume. |
1 |
| Decant Stand & Anaerobic Transfer Luer-to-Luer Holds syringes upright so aspirate separates, and transfers graft in a closed Luer path. |
1 |
| Syringe Stop Lock for 10 cc Syringes Holds the plunger back so vacuum is mechanical during small-volume harvesting. |
1 |
| Syringe Stop Lock for 20 cc Syringes Same hold for the 20cc syringes used through the main part of the harvest. |
1 |
A fat transfer case is a chain: infiltrate, harvest, separate, transfer, inject. Each step needs its own instrument, and the case stops at whichever one is missing.
Buying individually is how gaps appear. A surgeon orders the cannulas the last case needed, then finds the next case wants a calibre that was never bought, or that the harvester and the injector do not share a connection standard and the graft has to be moved between syringe formats mid-case.
Every cannula in these sets is Super Luer Lock, so the whole chain runs on one connection. Nothing needs an adapter, and there is no point in the case where the graft is decanted because two instruments would not join.
The calibre choices are the other half. Each set carries several injection sizes rather than one, because a face is not one plane and a breast is not one layer. Owning one calibre means placing the wrong grade of thread somewhere, and that shows in the result rather than in the case.
Every instrument in the set is German stainless steel, fully reusable and steam autoclavable to 134°C. Clean each cannula immediately after use, before graft and tumescent residue set into the lumen, and flush until the water runs clear. Check port edges and hub threads at every cycle: in a set, one worn instrument changes the behaviour of its own step without affecting the rest, which makes the fault harder to trace than on a single cannula.
|
Buy online |
Distributor, importer, or hospital group? Get bulk pricing, OEM manufacturing, and custom branding on the full range. |
Manufactured by Healermed Instruments, a surgical instruments manufacturer and exporter based in Sialkot, Pakistan. Factory-direct pricing removes the importer and distributor layer. Production runs under an ISO 13485 and FDA CGMP quality system, with ISO 9001 and CE Mark certification. OEM manufacturing and custom branding are available for distributor and brand-owner orders.
| Fat Transfer Set for Breasts A complete breast fat transfer set: infiltration, aggressive harvesting, three spoon tip injection calibres and the processing accessories, sized for the volumes a breast case needs. |
| Cannula Set for Buttock Reshaping and Body Contouring A complete buttock reshaping and body contouring set: two Mercedes tip cannulas for removal, three spoon tip injectors for placement, and two V-dissectors for releasing the recipient site. |
What is included in this set?
8 items, one of each, covering the full sequence of the procedure. The complete list with sizes is in the table above, and every item is linked to its own product page.
Why are there several injection calibres?
Because the recipient site is not one plane. Different depths take different grades of thread, and placing the wrong one shows in the result rather than in the case. Carrying the calibres together means the choice is made at the table.
Can I buy the items separately?
Yes. Every instrument in this set is sold individually and each is linked in the contents table above. The set exists so nothing in the sequence is missing when the case runs.
Can the set be customised?
Yes. Calibres, lengths and contents can be changed, and instruments added or removed. Send your specification through the wholesale request page and our production team will confirm what can be produced, including custom branding for distributor and OEM orders.
Is everything autoclavable?
Yes. Every instrument in the set is German stainless steel and steam autoclavable to 134°C.
What is the minimum order quantity for bulk orders?
The minimum order quantity is agreed per order rather than set at a fixed number. Send us the sets and quantities you need through the wholesale request page and we will confirm the minimum for that specification.