The Angled Tumescent Infiltration Cannula with Toomey Hub is a blunt-tip cannula with a bent working shaft, built to fit 60cc Toomey-tip syringes. The wide, non-Luer Toomey opening lets a full 60cc syringe empty quickly instead of being throttled by a narrow taper, and the angle keeps that large syringe body tilted away from the skin. This fitting is made from 2.0mm (14G) upward. See the full Angled Tumescent Infiltration Cannulas range for other fittings.
Buyers also search for this instrument as a 60cc Toomey angled cannula, a syringe tumescent infiltrator, or a bent fat grafting cannula.
At a Glance
A Toomey tip is a wide-bore syringe fitting, not a Luer taper. It exists because 60cc syringes are used where volume matters more than fine control. A 60cc syringe is also a large object to hold against a curved surface, which is where the angled shaft helps: the syringe stays tilted clear while the working section runs flat in the plane.
An angled cannula has a bend in the shaft, so the working section travels at an angle to the hub axis instead of running straight back from it. That changes the direction of the pass itself, which is the difference between an angled cannula and a bayonet one: a bayonet steps the shaft sideways and then runs parallel again, while an angle redirects where the tip actually goes.
The practical gain is reach. The body is curved, and a straight cannula entering a flank, hip or submental area has to be forced to an awkward wrist position to stay in the subcutaneous plane as the surface falls away. An angled shaft follows that curve instead of fighting it, so a single entry port covers more area and the surgeon's wrist stays in a neutral position through the pass.
The second gain is clearance at the skin. Because the hub sits at an angle rather than flat against the surface, the syringe or handpiece is held up and away from the area being filled. The surgeon is not pressing on tissue that is in the middle of taking up solution, which makes it easier to read turgor as the endpoint approaches.
The distal tip is closed and rounded. It separates the subcutaneous plane by blunt dissection as the cannula advances, pushing vessels and nerves aside rather than dividing them, and side holes along the working section release the solution along the length of the pass rather than at one point.
| Material | German stainless steel |
| Fitting | Toomey hub, 60cc syringes |
| Shaft shape | Angled — working section bent away from the hub axis |
| Tip | Closed blunt tip with side holes |
| Diameters | 2.0mm (14G), 2.4mm (13G), 2.5mm (13G), 3.0mm (11G), 3.5mm (10G), 4.0mm (8G), 4.5mm (7G), 5.0mm (6G), 6.0mm (4G) |
| Lengths | 3, 5, 7, 10, 12, 14, 15, 20, 25, 30, 35cm (by diameter) |
| Reusable | Yes — steam autoclavable to 134°C |
| Custom sizes | Available on request |
| Compliance | FDA CGMP, ISO 13485, ISO 9001, CE Mark |
The cannula is made from German stainless steel with a passivated surface that resists corrosion and pitting through repeated cleaning cycles. It is reusable and can be steam autoclaved at 134°C. Flush the lumen and every side hole with clean water immediately after use and dry fully before autoclaving. On an angled cannula, flush from both ends: any bend in a lumen is where residue settles first, and a partly blocked shaft changes how the solution distributes on the next case.
The Toomey fitting starts at 2.0mm, so for finer facial infiltration below 2.0mm choose the Luer lock version instead. Within the Toomey range, 2.5mm to 4.0mm in 25cm to 35cm suits large body areas, while 2.0mm to 2.5mm in 15cm to 25cm suits arms, neck and smaller curved regions.
Buying for your practice? Order online at factory-direct prices, straight from the manufacturer — no distributor markup.
Distributor, importer, or hospital group? Get bulk pricing, OEM manufacturing, and custom branding on the full cannula range.
Manufactured by Healermed Instruments, a surgical instruments manufacturer and exporter based in Sialkot, Pakistan. Factory-direct pricing removes the importer and distributor layer. Production runs under an ISO 13485 and FDA CGMP quality system, with ISO 9001 and CE Mark certification. OEM manufacturing and custom branding are available for distributor and brand-owner orders.
Other fittings in the same cannula range:
What is a Toomey hub angled cannula used for?
It is used with 60cc Toomey-tip syringes for large-volume tumescent infiltration and in fat grafting workflows. The wide non-Luer hub lets a full syringe empty quickly, and the angled shaft keeps that large syringe body clear of the skin while the working section stays in the plane.
What is the difference between an angled cannula and a straight cannula?
An angled cannula has a bend in the shaft, so the working section travels at an angle to the hub; a straight cannula runs in one line. The angle lets the cannula follow a curved body surface and stay in the subcutaneous plane without the surgeon twisting the wrist. A straight cannula is simpler to clean and store.
Is this cannula autoclavable?
Yes. The instrument is fully reusable and can be steam autoclaved at 134°C. Flush the lumen and every side hole with clean water immediately after use, remove all residue before sterilization, and dry completely. Flush from both ends so nothing is left sitting in the bend, where residue collects first.
What is the minimum order quantity for bulk orders?
The minimum order quantity is agreed per order rather than set at a fixed number. Send us the sizes, fittings and quantities you need through the wholesale request page and we will confirm the minimum for that specification. This lets a small distributor start with a trial order and a larger importer scale up on the same terms.
Do you provide samples?
Yes. Samples are available on request and the buyer covers the shipping charges. Tell us the diameter and length you want to evaluate and we will confirm what can be sent. Testing a sample first confirms the hub seats correctly on the 60cc syringes you already stock.
Can I order a custom size?
Yes. Custom diameters, working lengths, bend angles and hole patterns are available on request in addition to the standard size grid. Send your specification through the wholesale request page and our production team will confirm what can be produced. Custom branding is also available for distributor and OEM orders.