Buy Online
Add to Cart Now
Your shopping cart is empty!
Lorem Ipsum is simply dummy text of the printing and typesetting industry.
Globally certified & registered manufacturer
Globally trusted & secured payment methods
The Three Port In Line Liposuction Cannula with Universal Luer Lock fitting is a blunt-tip aspiration cannula with three round ports in a single straight line along one side of the shaft, used to remove subcutaneous fat under vacuum during liposuction. It is listed under Three Port In Line Liposuction Cannulas, part of the Healermed Liposuction Cannulas and Accessories range.
Surgeons also refer to these instruments as in-line port cannulas, three hole in line lipo cannulas, single-side port cannulas, or linear port aspiration cannulas.
At a Glance
Luer lock is a standard, but manufacturing tolerances differ between brands, and a hub cut to the tight end of the tolerance band can seat poorly on some syringes. A universal hub is machined to sit centrally in that band, so it locks properly across whatever stock is on the shelf that week. Under vacuum a poor seat is not just annoying, it leaks.
The three ports sit in one straight row along a single side of the shaft, evenly spaced and all facing the same way. That is the whole difference from a Mercedes tip, where three ports are spread around the circumference. Here every opening draws in the same direction at once.
The consequence is that the cannula is aimed rather than swept. Rotate the shaft and the whole aperture turns with it, so the surgeon decides exactly which plane the fat comes from — deep by turning the row down, superficial by turning it up. On a radial pattern that choice is not available, because some ports always face the skin and some always face the muscle.
Because the row runs along the shaft rather than around it, the working aperture is long. One pass draws from a strip of tissue rather than a point, which clears a defined lane quickly. The trade is that all the vacuum load sits on one side, so the cannula tends to pull toward the ports and the hand must hold the line. That is a fair trade for surgeons who want directional control and are used to correcting for it.
The distal tip is closed and rounded. It separates the plane by blunt dissection as the cannula advances, pushing vessels and nerves aside rather than dividing them, and the vacuum works through the three side ports rather than the end of the shaft.
| Material | German stainless steel |
| Fitting | Universal Luer lock |
| Opening pattern | Three round ports in a single straight line on one side of the shaft |
| Tip | Closed blunt tip |
| Diameters | 1.0mm (19G), 1.1mm (19G), 1.2mm (18G), 1.4mm (17G), 1.5mm (17G), 1.6mm (16G), 1.8mm (15G), 2.0mm (14G), 2.4mm (13G), 2.5mm (13G), 3.0mm (11G), 3.5mm (10G), 4.0mm (8G), 4.5mm (7G), 5.0mm (6G), 6.0mm (4G) |
| Lengths | 3, 4, 5, 7, 7.5, 8, 9, 10, 12, 14, 15, 20, 25, 30, 35cm (by diameter) |
| Reusable | Yes — steam autoclavable to 134°C |
| Custom sizes | Available on request |
| Compliance | FDA CGMP, ISO 13485, ISO 9001, CE Mark |
The cannula is made from German stainless steel with a passivated surface that resists corrosion and pitting through repeated cleaning cycles. It is reusable and can be steam autoclaved at 134°C. Flush the lumen and every opening with clean water immediately after use and dry fully before autoclaving. Because all three ports sit on one side, hold that side down while flushing so water runs through each opening rather than past them, and check every port under light before sterilization.
Diameter sets how much fat comes out per pass and length sets the reach. For body contouring of the abdomen, flanks and thighs, the 3.0mm to 4.0mm diameters in 25cm to 35cm are the usual working range. The 2.0mm to 2.5mm range in 15cm to 25cm covers arms, the neck and superficial work. The 1.0mm to 1.5mm diameters in 5cm to 12cm are for facial and submental contouring. Match the fitting to the syringe, vacuum line or handpiece already in your theater.
Buying for your practice? Order online at factory-direct prices, straight from the manufacturer — no distributor markup.
Distributor, importer, or hospital group? Get bulk pricing, OEM manufacturing, and custom branding on the full cannula range.
Manufactured by Healermed Instruments, a surgical instruments manufacturer and exporter based in Sialkot, Pakistan. Factory-direct pricing removes the importer and distributor layer. Production runs under an ISO 13485 and FDA CGMP quality system, with ISO 9001 and CE Mark certification. OEM manufacturing and custom branding are available for distributor and brand-owner orders.
Other fittings in the same cannula range:
What is a Universal Luer Lock three port in line liposuction cannula used for?
It is used to remove subcutaneous fat under vacuum during liposuction and body contouring. Three ports in one line along a single side give a long working aperture that draws in one direction, so the surgeon aims the openings at the layer being treated and clears a defined lane in each pass.
What is the difference between an in-line port and a Mercedes tip cannula?
On a Mercedes tip the three ports sit around the circumference, so the draw is symmetrical and the plane is fixed by how deep the shaft sits. On an in-line cannula all three face one way, so rotating the shaft selects the plane. Mercedes tracks straighter; in-line gives directional control.
Is this cannula autoclavable?
Yes. The instrument is fully reusable and can be steam autoclaved at 134°C. Flush the lumen and every opening with clean water immediately after use, remove all residue before sterilization, and dry completely. Inspect each opening under light at every cycle, since edge condition decides how the cannula behaves in tissue.
What is the minimum order quantity for bulk orders?
The minimum order quantity is agreed per order rather than set at a fixed number. Send us the sizes, fittings and quantities you need through the wholesale request page and we will confirm the minimum for that specification. This lets a small distributor start with a trial order and a larger importer scale up on the same terms.
Do you provide samples?
Yes. Samples are available on request and the buyer covers the shipping charges. Tell us the diameter and length you want to evaluate and we will confirm what can be sent. Testing a sample against the syringe brands you actually stock confirms the universal hub fits your supply.
Can I order a custom size?
Yes. Custom diameters, working lengths and port configurations are available on request in addition to the standard size grid. Send your specification through the wholesale request page and our production team will confirm what can be produced. Custom branding is also available for distributor and OEM orders.