Buy Online
Add to Cart Now
Your shopping cart is empty!
Lorem Ipsum is simply dummy text of the printing and typesetting industry.
Globally certified & registered manufacturer
Globally trusted & secured payment methods
Liposuction Cannulas and Accessories › Toledo V-Dissector Liposuction Cannulas › Toledo V-Dissector Liposuction Cannula – Black Power Handle
The Toledo V-Dissector Liposuction Cannula with Black Power Handle fitting is supplied with a hub built for that equipment, carrying the same shaft and tip as every other fitting in the range. It is listed under Toledo V-Dissector Liposuction Cannulas, part of the Healermed Liposuction Cannulas and Accessories range.
Surgeons also search for this instrument as a Toledo V dissector, a V dissector cannula, a pre-tunnelling liposuction cannula, or a Toledo dissector cannula.
At a Glance
Operating lights are bright and directional, and a polished steel handle reflects them straight back at the surgeon. An anodized black handle removes that reflection at the point closest to the eye line, and colour-codes this instrument against the others on a busy tray.
The Toledo V-dissector is not an aspiration cannula. The shaft is solid and carries no ports; the working end is formed into a blunt V, and the whole job of the instrument is to open a plane rather than remove anything through it.
The V works by spreading. As the instrument advances, the two arms separate tissue along the plane in front of them, pushing vessels, nerves and fibrous strands aside into the notch rather than dividing them. A round blunt tip pushes tissue ahead of itself and compresses it; a V splits it and travels between the halves, which is why the dissector passes through a plane that a plain cannula would have to force its way along.
Surgeons use it before the aspiration cannula and before grafting. Pre-tunnelling with a V-dissector establishes the plane the case will be worked in, so the passes that follow travel where they are meant to instead of finding their own route. In fat grafting it does the same job for the recipient site: the pocket is created deliberately, then filled.
Because there is no port and no sharpened edge, it neither aspirates nor divides. That is the argument for using it in planes where a sharpened dissector would be unacceptable, and it is equally the reason it will not release dense scar. For that, a sharpened dissector is the correct instrument and this one is not.
| Material | German stainless steel |
| Fitting | Black anodized, low glare under lights |
| Openings | No aspiration ports — solid shaft behind the V tip |
| Tip | Blunt V-shaped dissecting tip |
| Diameters | 1.0mm (19G), 1.1mm (19G), 1.2mm (18G), 1.4mm (17G), 1.5mm (17G), 1.6mm (16G), 1.8mm (15G), 2.0mm (14G), 2.4mm (13G), 2.5mm (13G), 3.0mm (11G), 3.5mm (10G), 4.0mm (8G), 4.5mm (7G), 5.0mm (6G), 6.0mm (4G) |
| Lengths | 3, 4, 5, 7, 7.5, 8, 9, 10, 12, 14, 15, 20, 25, 30, 35cm (by diameter) |
| Reusable | Yes — steam autoclavable to 134°C |
| Custom sizes | Available on request |
| Compliance | FDA CGMP, ISO 13485, ISO 9001, CE Mark |
Choose the black handle for glare reduction or tray colour-coding; the shaft and tip are identical to the other handle versions. This is a plane-forming instrument, so size follows the area being opened rather than any removal rate. The 3.0mm to 4.0mm diameters in 25cm to 35cm cover most body pre-tunnelling across the abdomen, flanks and thighs. The 2.0mm to 2.5mm range in 15cm to 25cm suits arms, the neck and facial work. If the plane is held down by dense scar the V will not release it and a sharpened dissector is the correct instrument instead.
The instrument is made from German stainless steel with a passivated surface that resists corrosion and pitting through repeated cleaning cycles. It is reusable and can be steam autoclaved at 134°C. Clean immediately after use and dry fully before autoclaving. A solid shaft has no lumen to flush, which makes cleaning simpler, but the notch of the V traps tissue and is easy to skip. Brush inside the V and inspect it under light at every cycle, and sight along the arms to confirm neither has been bent, since a distorted V no longer spreads evenly.
Buying for your practice? Order online at factory-direct prices, straight from the manufacturer — no distributor markup.
Distributor, importer, or hospital group? Get bulk pricing, OEM manufacturing, and custom branding on the full range.
Manufactured by Healermed Instruments, a surgical instruments manufacturer and exporter based in Sialkot, Pakistan. Factory-direct pricing removes the importer and distributor layer. Production runs under an ISO 13485 and FDA CGMP quality system, with ISO 9001 and CE Mark certification. OEM manufacturing and custom branding are available for distributor and brand-owner orders.
| Luer Lock Standard Luer lock syringes and suction tubing |
Stainless Steel Luer Lock All-steel hub for heavy autoclave cycles |
| Super Luer Lock Larger bore, longer thread, heavier hub |
Threaded Fitting Threaded reusable handles and tubing connectors |
| Fixed Power Handle Integrated handle, permanently attached |
Grooved Power Handle Grooved grip for wet-glove control |
| Toomey Hub 60cc 60cc Toomey-tip syringes, from 2.0mm up |
MicroAire PAL Compatible MicroAire PAL power-assisted handpieces |
| Lumsail Compatible Lumsail machine handpieces |
Universal Luer Lock Fits Luer lock across syringe brands |
| Vibrasat Quick Lock Vibrasat quarter-turn quick-lock coupling |
BeautiFill Laser Compatible BeautiFill laser lipolysis handpieces |
| Toledo V-Dissector Liposuction Cannula All 13 fittings on one product page |
Toledo V-Dissector Liposuction Cannulas The full category |
| Liposuction Cannulas Every cannula type and port pattern we make |
Liposuction Accessories Handles, hubs and cannulas for liposuction |
What is a toledo v-dissector liposuction cannula used for?
It is used to open and establish a tissue plane before liposuction or fat grafting. The blunt V-shaped tip spreads tissue apart as the instrument advances, pushing vessels, nerves and fibrous strands aside rather than dividing them, so the passes that follow travel in the plane the surgeon intended.
What is the difference between a V-dissector and a sharp cut dissector?
A V-dissector has a blunt V tip that spreads tissue apart along a plane, pushing vessels and strands aside without dividing them. A sharp cut dissector carries a sharpened edge and divides fibrous bands deliberately. The V is the safer instrument and will not release dense scar; the sharpened one will, and demands far more control.
Is this instrument autoclavable?
Yes. It is fully reusable and can be steam autoclaved at 134°C. Clean immediately after use, remove all residue before sterilization, and dry completely.
Which size should I use?
The 3.0mm to 4.0mm diameters in 25cm to 35cm cover most body pre-tunnelling across the abdomen, flanks and thighs. Use 2.0mm to 2.5mm in 15cm to 25cm for arms, the neck and facial work. Size follows the area being opened rather than any removal rate, since this instrument aspirates nothing.
What is the minimum order quantity for bulk orders?
The minimum order quantity is agreed per order rather than set at a fixed number. Send us the sizes, fittings and quantities you need through the wholesale request page and we will confirm the minimum for that specification.
Do you provide samples?
Yes. Samples are available on request and the buyer covers the shipping charges. A sample also lets you run the anodized handle through your own sterilization protocol first.
Can I order a custom size?
Yes. Custom diameters, working lengths and configurations are available on request in addition to the standard size grid. Send your specification through the wholesale request page and our production team will confirm what can be produced.