Shop by Instrument Type

Shop by Instrument Type

We use cookies 🍪
We use cookies and other similar technologies to improve your browsing experience and the functionality of our site. Learn more in our GDPR & Privacy Policy.

Two Parallel One Central Liposuction Cannula – Super Luer Lock

Two Parallel Ports One Central Port liposuction cannula with Super Luer Lock hub, German stainless steel
Two Parallel One Central Liposuction Cannula – Super Luer Lock
Liposuction Cannulas and Accessories › Two Parallel Ports One Central Port Liposuction Cannulas › Two Parallel Ports One Central Port Liposuction Cannula – Super Luer Lock The Two Parallel Ports One Central Port Liposuction Cannula with Super Luer... Read More
$15.00

Available Options

Direct Manufacturer B2B / OEM

Buy Online

Add to Cart Now

Bulk & Wholesale

Volume pricing & private label

Factory Quote

Logo & Name Engraving

FREE

Add your logo or name in checkout notes

Guide

Custom Sizes

Any length, curvature, or modification — to your spec

Request

Certified Quality

Globally certified & registered manufacturer

  • FDA · cGMPUS Registered & GMP Compliant
  • CE MarkingEU MDR Compliant
  • ISO 13485Medical Devices QMS
  • ISO 9001Quality Management
  • EUDAMEDEU Registered
SSL SECURED

Your Security, Our Priority

Globally trusted & secured payment methods

  • PayPal
  • Visa / Mastercard
  • Apple Pay
  • Google Pay
  • Bank transfer

Liposuction Cannulas and AccessoriesTwo Parallel Ports One Central Port Liposuction CannulasTwo Parallel Ports One Central Port Liposuction Cannula – Super Luer Lock

The Two Parallel Ports One Central Port Liposuction Cannula with Super Luer Lock fitting is a two parallel ports one central port liposuction cannula is a blunt-tip liposuction cannula with three grouped openings: two parallel ports nearest the tip and one central port set behind them. It is listed under Two Parallel Ports One Central Port Liposuction Cannulas, part of the Healermed Liposuction Cannulas and Accessories range.

Surgeons also refer to these liposuction cannulas as two parallel port cannulas, leading pair port cannulas, grouped three port lipo cannulas, or two-above-one port aspiration cannulas.

At a Glance

  • Instrument type: Two Parallel Ports One Central Port liposuction aspiration cannula, reusable
  • Fitting: Larger bore, longer thread, heavier hub
  • Opening: Two parallel ports nearest the tip with one central port set behind them
  • Tip: Closed blunt tip
  • Diameters: 1.0mm (19G) to 6.0mm (4G)
  • Working lengths: 3cm to 35cm
  • Material: German stainless steel
  • Sterilization: Steam autoclavable to 134°C
  • Manufacturer: Healermed Instruments, Sialkot, Pakistan

Two Parallel Ports One Central Port Liposuction Cannula — Super Luer Lock

Aspiration speed is limited by the narrowest point in the suction path. If the hub is narrower than the opening in the shaft, the cannula never performs to its size. The Super Luer Lock bore keeps the shaft as the controlling factor, with a longer thread on a heavier body that holds under sustained vacuum.

How the Port Order Works

Three openings, arranged with the two parallel ports nearest the tip and the single central port set behind them. The count is the same as a central-port-first cannula; the order along the shaft is reversed, and that order is what changes how the instrument behaves in a pass.

With the pair leading, the widest part of the aperture reaches new tissue first. As the cannula advances, the two parallel ports open the plane across their span and the central port behind them works tissue that has already been engaged. Removal therefore starts wide and finishes narrow on every forward stroke, which spreads the draw across the front of the pass instead of concentrating it at a single leading opening.

The practical effect is a smoother entry into untreated tissue. A single leading port bites at one point and can pull the cannula toward it; two leading ports share that load between them, so the instrument tracks straighter as it advances and is less inclined to dig at the start of a stroke. Surgeons who work in long forward passes tend to prefer this order for that reason.

The trailing central port then acts as the finishing opening of the stroke, taking the last of the tissue the pair has opened. Total removal is roughly three times a single hole, held within a compact group so the surgeon can still judge how much has come from any one area. The distal tip is closed and rounded, separating the plane by blunt dissection while the vacuum works through the three ports rather than the end of the shaft.

Key Features

  • Larger internal bore keeps the shaft, not the hub, as the limiting factor
  • Two parallel ports lead the stroke, spreading the draw across the front of the pass
  • Load shared between two leading openings, so the cannula tracks straighter as it advances
  • Central port behind finishes the tissue the pair has opened
  • Roughly three times the removal of a single hole, held in a compact group
  • Closed blunt tip separates the plane without cutting vessels or nerves
  • One-piece German stainless steel shaft, fully reusable and autoclavable
  • Custom diameters, lengths and port order available on request

Specifications

MaterialGerman stainless steel
FittingLarger bore, longer thread, heavier hub
OpeningTwo parallel ports nearest the tip with one central port set behind them
TipClosed blunt tip
Diameters1.0mm (19G), 1.1mm (19G), 1.2mm (18G), 1.4mm (17G), 1.5mm (17G), 1.6mm (16G), 1.8mm (15G), 2.0mm (14G), 2.4mm (13G), 2.5mm (13G), 3.0mm (11G), 3.5mm (10G), 4.0mm (8G), 4.5mm (7G), 5.0mm (6G), 6.0mm (4G)
Lengths3, 4, 5, 7, 7.5, 8, 9, 10, 12, 14, 15, 20, 25, 30, 35cm (by diameter)
ReusableYes — steam autoclavable to 134°C
Custom sizesAvailable on request
ComplianceFDA CGMP, ISO 13485, ISO 9001, CE Mark

Clinical Applications

  • Long forward passes across the abdomen, flanks and thighs
  • Mid-stage body contouring between debulking and final refinement
  • Entering untreated tissue where a single leading port would dig
  • Arm, neck and submental work with the 2.0mm to 2.5mm diameters

Material and Sterilization

The cannula is made from German stainless steel with a passivated surface that resists corrosion and pitting through repeated cleaning cycles. It is reusable and can be steam autoclaved at 134°C. Flush the lumen and the opening with clean water immediately after use and dry fully before autoclaving. The three ports sit close together and at different points along the shaft, so turn the cannula while flushing and confirm water runs from all three before drying. Check each edge under light at every cycle, since the pattern only tracks straight while all three draw evenly.

How to Choose

Diameter sets how much fat comes out per pass and length sets the reach. For body contouring of the abdomen, flanks and thighs, the 3.0mm to 4.0mm diameters in 25cm to 35cm are the usual working range and where the leading-pair order is most useful, since the passes are longest there. The 2.0mm to 2.5mm range in 15cm to 25cm covers arms, the neck and refinement work. The 1.0mm to 1.5mm diameters in 5cm to 12cm are for facial and submental contouring. Match the fitting to the syringe, vacuum line or handpiece already in your theater.

Buying for your practice? Order online at factory-direct prices, straight from the manufacturer — no distributor markup.

Shop Online

Distributor, importer, or hospital group? Get bulk pricing, OEM manufacturing, and custom branding on the full cannula range.

Request Wholesale Price

Why Buy Direct From the Manufacturer

Manufactured by Healermed Instruments, a surgical instruments manufacturer and exporter based in Sialkot, Pakistan. Factory-direct pricing removes the importer and distributor layer. Production runs under an ISO 13485 and FDA CGMP quality system, with ISO 9001 and CE Mark certification. OEM manufacturing and custom branding are available for distributor and brand-owner orders.

Choose Your Fitting

Every fitting below carries the same two parallel ports one central port shaft, the same closed blunt tip and the same size grid. Pick the one that matches the syringe, vacuum line or handpiece already in your theater.

Luer Lock Liposuction Cannula
Standard Luer lock syringes and suction tubing
Stainless Steel Luer Lock Liposuction Cannula
All-steel hub for heavy autoclave cycles
Threaded Fitting Liposuction Cannula
Threaded reusable handles and tubing connectors
Fixed Power Handle Liposuction Cannula
Integrated handle, permanently attached
Grooved Power Handle Liposuction Cannula
Grooved grip for wet-glove control
Black Power Handle Liposuction Cannula
Black anodized, low glare under lights
Toomey Hub 60cc Liposuction Cannula
60cc Toomey-tip syringes, from 2.0mm up
MicroAire PAL Compatible Liposuction Cannula
MicroAire PAL power-assisted handpieces
Lumsail Compatible Liposuction Cannula
Lumsail machine handpieces
Universal Luer Lock Liposuction Cannula
Fits Luer lock across syringe brands
Vibrasat Quick Lock Liposuction Cannula
Vibrasat quarter-turn quick-lock coupling
BeautiFill Laser Compatible Liposuction Cannula
BeautiFill laser lipolysis handpieces

More Liposuction Cannulas and Accessories

Healermed manufactures the full range of cannulas for liposuction, from single hole finishing cannulas to high-flow debulking patterns, in 84 diameter and length combinations.

Two Parallel Ports One Central Port Liposuction Cannula
All 13 fittings on one product page
Two Parallel Ports One Central Port Liposuction Cannulas
The full two parallel ports one central port category
Liposuction Cannulas
Every port pattern and cannula type we make
Liposuction Accessories
Handles, hubs and cannulas for liposuction

Frequently Asked Questions

What is a two parallel ports one central port liposuction cannula used for?

It is used to remove subcutaneous fat under vacuum during liposuction and body contouring. Two parallel ports nearest the tip lead each forward pass and spread the draw across its front, while the central port behind finishes the tissue they have opened, giving roughly three times the removal of a single hole in a compact group.

What is the difference between this and a one central port, two parallel ports cannula?

Both carry the same three openings. Here the parallel pair sits nearest the tip and the central port behind, so the widest part of the aperture meets new tissue first and the load is shared between two leading openings. On the central-port-first version a single opening leads, which gives a more defined aiming point but concentrates the draw at one place.

Is this cannula autoclavable?

Yes. The instrument is fully reusable and can be steam autoclaved at 134°C. Flush the lumen and the opening with clean water immediately after use, remove all residue before sterilization, and dry completely. Inspect the opening edge under light at every cycle, since edge condition decides how the cannula behaves in tissue.

Which size should I use?

For body contouring of the abdomen, flanks and thighs, 3.0mm to 4.0mm diameters in 25cm to 35cm are the usual range and where the leading-pair order helps most, since the passes are longest there. Arms, neck and refinement work suit 2.0mm to 2.5mm in 15cm to 25cm. Facial and submental contouring uses 1.0mm to 1.5mm in 5cm to 12cm.

What is the minimum order quantity for bulk orders?

The minimum order quantity is agreed per order rather than set at a fixed number. Send us the sizes, fittings and quantities you need through the wholesale request page and we will confirm the minimum for that specification. This lets a small distributor start with a trial order and a larger importer scale up on the same terms.

Do you provide samples?

Yes. Samples are available on request and the buyer covers the shipping charges. Tell us the diameter and length you want to evaluate and we will confirm what can be sent. Testing a sample first confirms the hub seats correctly in your existing tubing set.

Can I order a custom size?

Yes. Custom diameters, working lengths and opening dimensions are available on request in addition to the standard size grid. Send your specification through the wholesale request page and our production team will confirm what can be produced. Custom branding is also available for distributor and OEM orders.

Brand: Healermed instruments Model: HM-6OP
Liposuction Cannulas and Accessories › Six Oval Port Liposuction Cannulas › Six Oval Port Liposuction Cannula A six oval port liposuc..
$12.00
Add to Cart
Brand: Healermed instruments Model: HM-ATP
Liposuction Cannulas and Accessories › Accelerator Three Port Liposuction Cannulas › Accelerator Three Port Liposuction Cannula An accelerator thre..
$12.00
Add to Cart
Brand: Healermed instruments Model: HM-FOM-R56
The Fomon TC Nasal Rasp Double Ended Sharp #5 and #6, 5mm is a specialized rhinoplasty instrument used for bone contouring and humpectomy refinement d..
$35.00
Add to Cart
Brand: Healermed instruments Model: HM-TTS-ULL
Liposuction Cannulas and Accessories › Tapered Tip Two Spiral Holes Liposuction Cannulas › Tapered Tip Two Spiral Holes Liposuction Cann..
$8.00
Add to Cart
Brand: Healermed instruments Model: HM-2SQ-SSLL
Liposuction Cannulas and Accessories › Two Square Ports In Line Liposuction Cannulas › Two Square Ports In Line Liposuction Cannula – St..
$12.00
Add to Cart
Brand: Healermed instruments Model: HM-LFA-GPH
Liposuction Cannulas and Accessories › Long Hole Fat Aspiration Tip Liposuction Cannulas › Long Hole Fat Aspiration Tip Liposuction Cann..
$25.00
Add to Cart
Brand: Healermed instruments Model: HM-MSH-BS-VQL
Liposuction Cannulas and Accessories › Multiport Speed Harvester Both End Sharp Liposuction Cannulas › Multiport Speed Harvester Both End Sharp Liposu..
$35.00
Add to Cart
Brand: Healermed instruments Model: HM-2P1C-SLL
Liposuction Cannulas and Accessories › Two Parallel Ports One Central Port Liposuction Cannulas › Two Parallel Ports One Central Port Li..
$15.00
Add to Cart
Healermed Support
Sales Agent · Online

Chat on WhatsApp
Only $650 to free shipping · $55 flat worldwide · Track order →