Buy Online
Add to Cart Now
Your shopping cart is empty!
Lorem Ipsum is simply dummy text of the printing and typesetting industry.
Globally certified & registered manufacturer
Globally trusted & secured payment methods
The Lums Compatible Tumescent Infiltration Cannula is a blunt-tip, multi-hole cannula with a hub machined to fit Lums machine handpieces, used to deliver tumescent or wetting solution before liposuction. The shaft, hole pattern and blunt tip are the same as the rest of the Healermed tumescent range; only the connection is machined for the Lums machine. It is supplied in bulk to distributors worldwide. See the full Tumescent Infiltration Liposuction Cannulas range for other fittings.
Buyers also search for this instrument as a Lums machine cannula, a machine-fit infiltrator, or a system-compatible tumescent cannula.
At a Glance
Equipment-specific hubs exist because handpiece manufacturers do not share a common fitting. A cannula that fits one machine will not seat in another, and forcing or adapting a fitting introduces play at exactly the point that carries mechanical load and holds the fluid seal. Ordering the correct hub for your machine is the only safe route.
The working section carries many small round holes spread in a staggered pattern along the shaft rather than grouped near the tip. Each hole releases a small share of the solution, so a single pass wets a long column of tissue evenly instead of pooling fluid at one point. The staggered layout means the openings do not sit in one straight line, so solution leaves the shaft on more than one side and spreads through the plane rather than tracking along a single channel.
The distal tip is closed and rounded. It separates the subcutaneous plane by blunt dissection as the cannula advances, pushing vessels and nerves aside rather than dividing them, which is why an infiltration cannula is not simply a long needle.
| Material | German stainless steel |
| Fitting | Lums machine compatible hub |
| Hole pattern | Many small round holes staggered along the working length |
| Tip | Closed blunt tip |
| Diameters | 1.0mm (19G), 1.1mm (19G), 1.2mm (18G), 1.4mm (17G), 1.5mm (17G), 1.6mm (16G), 1.8mm (15G), 2.0mm (14G), 2.4mm (13G), 2.5mm (13G), 3.0mm (11G), 3.5mm (10G), 4.0mm (8G), 4.5mm (7G), 5.0mm (6G), 6.0mm (4G) |
| Lengths | 3, 4, 5, 7, 7.5, 8, 9, 10, 12, 14, 15, 20, 25, 30, 35cm (by diameter) |
| Reusable | Yes — steam autoclavable to 134°C |
| Custom sizes | Available on request |
| Compliance | FDA CGMP, ISO 13485, ISO 9001, CE Mark |
The cannula is made from German stainless steel with a passivated surface that resists corrosion and pitting through repeated cleaning cycles. It is reusable and can be steam autoclaved at 134°C. Flush the lumen and every hole with clean water immediately after use and dry fully before autoclaving. A cannula with many small openings needs more attention here than a two-port design, because dried tumescent solution blocks small holes first and an uneven port flow shows up as uneven infiltration.
Order this fitting only if your handpiece takes it, and send us your machine details before placing a large order so we can confirm the hub matches. Diameter sets the flow rate and length sets the reach. For large-volume body infiltration of the abdomen, flanks, back and thighs, the 2.5mm to 4.0mm diameters in 25cm to 35cm are the usual working range, because they fill a large area in fewer passes. The 1.8mm to 2.5mm range in 15cm to 25cm suits arms, the neck and smaller regions. The 1.0mm to 1.5mm diameters in 5cm to 12cm are for facial and submental infiltration, where thin tissue needs a small-diameter cannula. Match the fitting to the syringe, pump or handpiece already in your theater.
Buying for your practice? Order online at factory-direct prices, straight from the manufacturer — no distributor markup.
Distributor, importer, or hospital group? Get bulk pricing, OEM manufacturing, and custom branding on the full cannula range.
Manufactured by Healermed Instruments, a surgical instruments manufacturer and exporter based in Sialkot, Pakistan. Factory-direct pricing removes the importer and distributor layer. Production runs under an ISO 13485 and FDA CGMP quality system, with ISO 9001 and CE Mark certification. OEM manufacturing and custom branding are available for distributor and brand-owner orders.
Trademark notice: All third-party equipment names are the property of their respective owners. Healermed Instruments is not affiliated with, endorsed by, or sponsored by any third-party equipment manufacturer. This cannula is independently manufactured and the compatibility reference is provided for the buyer's guidance only.
Other fittings in the same cannula range:
What is a Lums compatible tumescent cannula used for?
It is used to deliver tumescent or wetting solution into subcutaneous tissue when the cannula mounts into a Lums machine handpiece rather than a syringe or manual handle. The hole pattern and blunt tip work exactly as on a manual cannula; only the connection is machined for that equipment.
What is the difference between a tumescent infiltration cannula and an aspiration cannula?
An infiltration cannula delivers fluid into tissue; an aspiration cannula removes fat under vacuum. Infiltration cannulas are narrower, carry many small holes for even fluid spread, and connect to a syringe or pump. Aspiration cannulas have fewer, much larger ports designed to draw fat and connect to a vacuum line.
Why does this cannula have so many holes?
Many small holes spread the solution along the whole length of the pass instead of releasing it at one point. That gives a more even wetting of the treatment area, fewer passes to fill a large region, and less risk of a fluid pocket forming where a single port sat. The staggered layout also sends solution out on more than one side of the shaft.
Is this cannula autoclavable?
Yes. The instrument is fully reusable and can be steam autoclaved at 134°C. Flush the lumen and every hole with clean water immediately after use, remove all residue before sterilization, and dry completely. Check the holes under light before each cycle, since a blocked opening changes how the solution distributes on the next case.
What is the minimum order quantity for bulk orders?
The minimum order quantity is agreed per order rather than set at a fixed number. Send us the sizes, fittings and quantities you need through the wholesale request page and we will confirm the minimum for that specification. This lets a small distributor start with a trial order and a larger importer scale up on the same terms.
Do you provide samples?
Yes. Samples are available on request and the buyer covers the shipping charges. Send us your machine details with the diameter and length you want to evaluate. Testing a sample in your own handpiece before a bulk order is strongly recommended for any machine-mounted fitting.
Can I order a custom size?
Yes. Custom diameters, working lengths, and hole patterns are available on request in addition to the standard size grid. Send your specification through the wholesale request page and our production team will confirm what can be produced. Custom branding is also available for distributor and OEM orders.