Buy Online
Add to Cart Now
Your shopping cart is empty!
Lorem Ipsum is simply dummy text of the printing and typesetting industry.
Globally certified & registered manufacturer
Globally trusted & secured payment methods
Liposuction Cannulas and Accessories › Six Oval Port Liposuction Cannulas › Six Oval Port Liposuction Cannula – Toomey Hub 60cc
The Six Oval Port Liposuction Cannula with Toomey Hub 60cc fitting is a six oval port liposuction cannula is a blunt-tip liposuction cannula with six oval openings staggered along the shaft in two alternating rows, used to remove subcutaneous fat under vacuum during liposuction and body contouring. The oval ports draw along the line of travel and the staggered layout balances the load, so a large area clears quickly while the cannula still tracks straight. It is listed under Six Oval Port Liposuction Cannulas, part of the Healermed Liposuction Cannulas and Accessories range.
Surgeons also search for these liposuction cannulas as 6 port liposuction cannulas, six hole lipo cannulas, oval port aspiration cannulas, or multi port liposuction cannulas.
At a Glance
A Toomey tip is a wide-bore syringe fitting, not a Luer taper. It exists because aspirated fat is thick and moves slowly through a narrow connector. A matching Toomey hub keeps the whole path wide, so the shaft rather than the connector sets the working limit, and the syringe gives the surgeon vacuum they modulate by hand.
Six oval ports, set along the shaft in two alternating rows: three on one side, three on the other, offset so no port sits directly opposite another. Two design choices are working here at once, and each does a different job.
The oval shape sets how tissue enters. A round hole draws from a point and pulls fat sideways against a tight curve, which makes the draw surge as each opening blocks and clears. An oval is stretched along the line of travel, so tissue enters as a short continuous column in the direction the cannula is already moving. The result is a smoother release and less tendency to grab as the cannula advances.
The staggered layout sets how the cannula behaves in the plane. Ports facing one side only would pull the shaft toward that side and the hand would have to correct for it all the way through the pass. Alternating them balances the vacuum load across the shaft, so the cannula tracks straight and leaves an even tunnel. Because the two rows are offset rather than paired, adjacent passes overlap and the transitions between them stay soft.
Six openings put this at the high-flow end of the range: a large area clears in fewer passes than any low-port pattern manages. That speed is the trade. It belongs in the deep and mid layers and in areas with volume to spare, not in the superficial plane and not at the end of a case, where a single-hole or short-hole cannula gives the control to stop at the right contour. The distal tip is closed and rounded, separating the plane by blunt dissection while the vacuum works through the six oval ports rather than the end of the shaft.
| Material | German stainless steel |
| Fitting | 60cc Toomey-tip syringes, from 2.0mm up |
| Opening | Six oval ports staggered along the shaft in two alternating rows |
| Tip | Closed blunt tip |
| Diameters | 2.0mm (14G), 2.4mm (13G), 2.5mm (13G), 3.0mm (11G), 3.5mm (10G), 4.0mm (8G), 4.5mm (7G), 5.0mm (6G), 6.0mm (4G) |
| Lengths | 3, 5, 7, 10, 12, 14, 15, 20, 25, 30, 35cm (by diameter) |
| Reusable | Yes — steam autoclavable to 134°C |
| Custom sizes | Available on request |
| Compliance | FDA CGMP, ISO 13485, ISO 9001, CE Mark |
The cannula is made from German stainless steel with a passivated surface that resists corrosion and pitting through repeated cleaning cycles. It is reusable and can be steam autoclaved at 134°C. Flush the lumen and the opening with clean water immediately after use and dry fully before autoclaving. Six ports on two sides means residue can sit in openings the water never reaches, so turn the cannula through a full rotation while flushing and confirm water runs from all six before drying. Oval openings have longer edges than round holes, so run a light around each perimeter at every cycle rather than glancing at them.
The Toomey fitting starts at 2.0mm, so for finer facial work below 2.0mm choose the Luer lock version instead. Diameter sets how much fat comes out per pass and length sets the reach. This liposuction cannula is built for area, so the 3.5mm to 5.0mm diameters in 30cm to 35cm are the core working range for the abdomen, back and outer thighs. The 3.0mm in 25cm to 30cm suits flanks and smaller body areas. Below 2.5mm six ports give little advantage over a low-port pattern, and for superficial work and final shaping a single-hole or short-hole cannula is the right choice. Match the fitting to the syringe, vacuum line or handpiece already in your theater.
Buying for your practice? Order online at factory-direct prices, straight from the manufacturer — no distributor markup.
Distributor, importer, or hospital group? Get bulk pricing, OEM manufacturing, and custom branding on the full cannula range.
Manufactured by Healermed Instruments, a surgical instruments manufacturer and exporter based in Sialkot, Pakistan. Factory-direct pricing removes the importer and distributor layer. Production runs under an ISO 13485 and FDA CGMP quality system, with ISO 9001 and CE Mark certification. OEM manufacturing and custom branding are available for distributor and brand-owner orders.
Every fitting below carries the same six oval port shaft, the same closed blunt tip and the same size grid. Pick the one that matches the syringe, vacuum line or handpiece already in your theater.
| Luer Lock Liposuction Cannula Standard Luer lock syringes and suction tubing |
Stainless Steel Luer Lock Liposuction Cannula All-steel hub for heavy autoclave cycles |
| Super Luer Lock Liposuction Cannula Larger bore, longer thread, heavier hub |
Threaded Fitting Liposuction Cannula Threaded reusable handles and tubing connectors |
| Fixed Power Handle Liposuction Cannula Integrated handle, permanently attached |
Grooved Power Handle Liposuction Cannula Grooved grip for wet-glove control |
| Black Power Handle Liposuction Cannula Black anodized, low glare under lights |
MicroAire PAL Compatible Liposuction Cannula MicroAire PAL power-assisted handpieces |
| Lumsail Compatible Liposuction Cannula Lumsail machine handpieces |
Universal Luer Lock Liposuction Cannula Fits Luer lock across syringe brands |
| Vibrasat Quick Lock Liposuction Cannula Vibrasat quarter-turn quick-lock coupling |
BeautiFill Laser Compatible Liposuction Cannula BeautiFill laser lipolysis handpieces |
Healermed manufactures the full range of cannulas for liposuction, from single hole finishing cannulas to high-flow debulking patterns, in 84 diameter and length combinations.
| Six Oval Port Liposuction Cannula All 13 fittings on one product page |
Six Oval Port Liposuction Cannulas The full six oval port category |
| Liposuction Cannulas Every port pattern and cannula type we make |
Liposuction Accessories Handles, hubs and cannulas for liposuction |
What is a six oval port liposuction cannula used for?
It is used to remove subcutaneous fat under vacuum during liposuction and body contouring, in the high-volume stage over large areas. Six oval ports staggered across two sides give a wide, balanced draw, so a big surface is cleared in fewer passes while the cannula still tracks straight and leaves an even plane.
What is the difference between oval ports and round holes on a liposuction cannula?
A round hole draws from a point, pulling tissue sideways against a tight curve so the draw surges as each opening blocks and clears. An oval port is stretched along the shaft, so tissue enters as a short continuous column in the direction of travel. Oval ports release tissue more smoothly and are less likely to grab as the cannula advances.
Is this cannula autoclavable?
Yes. The instrument is fully reusable and can be steam autoclaved at 134°C. Flush the lumen and the opening with clean water immediately after use, remove all residue before sterilization, and dry completely. Inspect the opening edge under light at every cycle, since edge condition decides how the cannula behaves in tissue.
Which size should I use?
The 3.5mm to 5.0mm diameters in 30cm to 35cm are the core working range for the abdomen, back and outer thighs. Use 3.0mm in 25cm to 30cm for flanks and smaller body areas. Below 2.5mm six ports give little advantage, and for superficial work or final shaping a single-hole or short-hole liposuction cannula is the better choice.
What is the minimum order quantity for bulk orders?
The minimum order quantity is agreed per order rather than set at a fixed number. Send us the sizes, fittings and quantities you need through the wholesale request page and we will confirm the minimum for that specification. This lets a small distributor start with a trial order and a larger importer scale up on the same terms.
Do you provide samples?
Yes. Samples are available on request and the buyer covers the shipping charges. Tell us the diameter and length you want to evaluate and we will confirm what can be sent. Testing a sample first confirms the hub seats correctly on the 60cc syringes you already stock.
Can I order a custom size?
Yes. Custom diameters, working lengths and opening dimensions are available on request in addition to the standard size grid. Send your specification through the wholesale request page and our production team will confirm what can be produced. Custom branding is also available for distributor and OEM orders.