Buy Online
Add to Cart Now
Your shopping cart is empty!
Lorem Ipsum is simply dummy text of the printing and typesetting industry.
Globally certified & registered manufacturer
Globally trusted & secured payment methods
Liposuction Cannulas and Accessories › Long Hole Fat Aspiration Tip Liposuction Cannulas › Long Hole Fat Aspiration Tip Liposuction Cannula – Toomey Hub 60cc
The Long Hole Fat Aspiration Tip Liposuction Cannula with Toomey Hub 60cc fitting is a long hole fat aspiration tip liposuction cannula is a blunt-tip liposuction cannula with one long aspiration opening at the working tip, used to remove and harvest subcutaneous fat under vacuum during liposuction, body contouring and fat transfer. The long aperture keeps a steady column of tissue moving instead of drawing in surges, which suits high-volume removal and fat harvesting. It is listed under Long Hole Fat Aspiration Tip Liposuction Cannulas, part of the Healermed Liposuction Cannulas and Accessories range.
Surgeons also refer to these liposuction cannulas as fat aspiration cannulas, fat harvesting cannulas, long aperture lipo cannulas, or high-flow fat transfer cannulas.
At a Glance
A Toomey tip is a wide-bore syringe fitting, not a Luer taper. It exists because aspirated fat is thick and moves slowly through a narrow connector. A matching Toomey hub keeps the whole path wide, so the shaft rather than the connector sets the working limit, and the syringe gives the surgeon vacuum they modulate by hand.
This liposuction cannula carries a single long opening, cut along the shaft at the working tip and sized for throughput rather than for shaping. It is the highest-flow single-opening cannula in the Healermed range.
Flow is the whole design goal. Aspirated fat is thick, and on a cannula with small ports it moves in surges as each opening clears and blocks again. A long aperture keeps a continuous column of tissue entering the lumen, so the draw is steady instead of intermittent. For a surgeon that means fewer stalls mid-pass and less time spent clearing the line.
Steady flow matters twice over when the fat is being kept. In fat harvesting for grafting, tissue that is drawn through a narrow opening in surges is worked harder than tissue that enters a wide aperture in a smooth column. A long opening lets the same volume through at lower local force, which is why this pattern is the one reached for when the aspirate is going back into the patient.
The trade is control, and it should be stated plainly. A long aperture removes a lot per pass, so it belongs in the deep and mid layers and in areas with volume to spare. It is not a finishing cannula: once the shape is close, change to a short-hole or single-hole instrument. The tip is closed and rounded, separating the plane by blunt dissection while the vacuum works through the long side opening rather than the end of the shaft.
| Material | German stainless steel |
| Fitting | 60cc Toomey-tip syringes, from 2.0mm up |
| Opening | One long aspiration opening running along the shaft at the tip |
| Tip | Closed blunt tip |
| Diameters | 2.0mm (14G), 2.4mm (13G), 2.5mm (13G), 3.0mm (11G), 3.5mm (10G), 4.0mm (8G), 4.5mm (7G), 5.0mm (6G), 6.0mm (4G) |
| Lengths | 3, 5, 7, 10, 12, 14, 15, 20, 25, 30, 35cm (by diameter) |
| Reusable | Yes — steam autoclavable to 134°C |
| Custom sizes | Available on request |
| Compliance | FDA CGMP, ISO 13485, ISO 9001, CE Mark |
The cannula is made from German stainless steel with a passivated surface that resists corrosion and pitting through repeated cleaning cycles. It is reusable and can be steam autoclaved at 134°C. Flush the lumen and the opening with clean water immediately after use and dry fully before autoclaving. A long aperture is quick to inspect but its edges do all the work, so run a light along the full length of the opening at each cycle and check for any nick or dulled section. Flush the lumen from the hub end until the water runs clear, since a long opening holds more residue than a small port.
The Toomey fitting starts at 2.0mm, so for finer facial work below 2.0mm choose the Luer lock version instead. Diameter sets how much fat comes out per pass and length sets the reach. This liposuction cannula is built for throughput, so the 3.0mm to 4.5mm diameters in 25cm to 35cm are the core working range for high-volume removal and fat harvesting. The 2.5mm to 3.0mm range in 20cm to 30cm suits smaller harvest sites and flanks. For superficial work and final shaping, change to a short-hole or single-hole cannula, which removes far less per pass. Match the fitting to the syringe, vacuum line or handpiece already in your theater.
Buying for your practice? Order online at factory-direct prices, straight from the manufacturer — no distributor markup.
Distributor, importer, or hospital group? Get bulk pricing, OEM manufacturing, and custom branding on the full cannula range.
Manufactured by Healermed Instruments, a surgical instruments manufacturer and exporter based in Sialkot, Pakistan. Factory-direct pricing removes the importer and distributor layer. Production runs under an ISO 13485 and FDA CGMP quality system, with ISO 9001 and CE Mark certification. OEM manufacturing and custom branding are available for distributor and brand-owner orders.
Every fitting below carries the same long hole fat aspiration tip shaft, the same closed blunt tip and the same size grid. Pick the one that matches the syringe, vacuum line or handpiece already in your theater.
| Luer Lock Liposuction Cannula Standard Luer lock syringes and suction tubing |
Stainless Steel Luer Lock Liposuction Cannula All-steel hub for heavy autoclave cycles |
| Super Luer Lock Liposuction Cannula Larger bore, longer thread, heavier hub |
Threaded Fitting Liposuction Cannula Threaded reusable handles and tubing connectors |
| Fixed Power Handle Liposuction Cannula Integrated handle, permanently attached |
Grooved Power Handle Liposuction Cannula Grooved grip for wet-glove control |
| Black Power Handle Liposuction Cannula Black anodized, low glare under lights |
MicroAire PAL Compatible Liposuction Cannula MicroAire PAL power-assisted handpieces |
| Lumsail Compatible Liposuction Cannula Lumsail machine handpieces |
Universal Luer Lock Liposuction Cannula Fits Luer lock across syringe brands |
| Vibrasat Quick Lock Liposuction Cannula Vibrasat quarter-turn quick-lock coupling |
BeautiFill Laser Compatible Liposuction Cannula BeautiFill laser lipolysis handpieces |
Healermed manufactures the full range of cannulas for liposuction, from single hole finishing cannulas to high-flow debulking patterns, in 84 diameter and length combinations.
| Long Hole Fat Aspiration Tip Liposuction Cannula All 13 fittings on one product page |
Long Hole Fat Aspiration Tip Liposuction Cannulas The full long hole fat aspiration tip category |
| Liposuction Cannulas Every port pattern and cannula type we make |
Liposuction Accessories Handles, hubs and cannulas for liposuction |
What is a long hole fat aspiration tip liposuction cannula used for?
It is used to remove and harvest subcutaneous fat under vacuum during liposuction, body contouring and fat transfer. The long aspiration opening at the tip keeps a steady column of tissue moving into the lumen rather than drawing in surges, which gives high flow for volume removal and lower local force when the fat is being kept for grafting.
What is the difference between a long hole aspiration cannula and a multi-port cannula?
A multi-port cannula spreads the draw across several small openings, which clears an area evenly but moves fat in surges as each port blocks and clears. A long aperture keeps one continuous column of tissue entering the lumen, so flow is steadier and higher, which suits high-volume removal and fat harvesting.
Is this cannula autoclavable?
Yes. The instrument is fully reusable and can be steam autoclaved at 134°C. Flush the lumen and the opening with clean water immediately after use, remove all residue before sterilization, and dry completely. Inspect the opening edge under light at every cycle, since edge condition decides how the cannula behaves in tissue.
Which size should I use?
The 3.0mm to 4.5mm diameters in 25cm to 35cm are the core working range for high-volume removal and fat harvesting. Use 2.5mm to 3.0mm in 20cm to 30cm for smaller harvest sites and flanks. For superficial work and final shaping, change to a short-hole or single-hole liposuction cannula, since a long aperture removes far more per pass.
What is the minimum order quantity for bulk orders?
The minimum order quantity is agreed per order rather than set at a fixed number. Send us the sizes, fittings and quantities you need through the wholesale request page and we will confirm the minimum for that specification. This lets a small distributor start with a trial order and a larger importer scale up on the same terms.
Do you provide samples?
Yes. Samples are available on request and the buyer covers the shipping charges. Tell us the diameter and length you want to evaluate and we will confirm what can be sent. Testing a sample first confirms the hub seats correctly on the 60cc syringes you already stock.
Can I order a custom size?
Yes. Custom diameters, working lengths and opening dimensions are available on request in addition to the standard size grid. Send your specification through the wholesale request page and our production team will confirm what can be produced. Custom branding is also available for distributor and OEM orders.