Liposuction Cannulas and Accessories › Sharp Hole On Tip Extractor Injector Cannulas › Sharp Hole On Tip Extractor Injector Cannula – Luer Lock
The Sharp Hole On Tip Extractor Injector Cannula with Luer Lock fitting is used to place fat in fat transfer and fat grafting. It is listed under Sharp Hole On Tip Extractor Injector Cannulas, part of the Healermed Liposuction Cannulas and Accessories range.
At a Glance
The Luer lock is the standard connection for fat injection. A threaded collar screws onto the syringe so the joint holds while the surgeon presses the plunger. On an injector that matters more than on an aspiration cannula: injection pressure pushes outward at the hub, and a slip fit can separate mid-pass and lose both the graft and the plane.
This instrument works in both directions: it will take fat out and put fat back, which is why it is described as an extractor and injector. The opening sits at the tip and its edge is sharpened.
Extracting is what the sharp edge is for. A sharpened opening separates parcels of fat as the cannula is advanced, so small graft volumes can be harvested with the same instrument that will place them, without changing to a dedicated harvester for a facial case or a small touch-up.
Injecting uses the same opening in reverse. Because it sits at the tip rather than back along the shaft, fat leaves at the leading point, which lets the surgeon place a thread exactly where the tip is and see the effect immediately. On a small recipient site that directness is worth more than volume.
The sharpened edge is the caution as well as the feature. It cuts whatever reaches it, so it is placed under direct control and it is not a beginner's instrument in thin recipient tissue. Once dulled it tears instead of cutting and should be taken out of service.
An injector cannula is the delivery end of a fat transfer. The syringe supplies the pressure, but where the graft ends up, and in what form, is decided by the cannula: its diameter, its opening, and the way the surgeon moves it.
Placement is done in retrograde. The cannula is advanced through the recipient plane, and fat is laid down as it is withdrawn, so the graft fills the tunnel the cannula has just made rather than being forced into tissue ahead of it. Each pass deposits a thread of fat. A result is built from many of those threads, crossed and layered, not from a few large boluses.
That is why the opening matters. Its size sets the diameter of the thread laid down; its position sets which way the fat is directed as the cannula withdraws; and its edge decides whether the parcel passes cleanly or is sheared at the exit. A wider opening places more per pass and fills faster; a smaller one places less and gives finer control in thin tissue where the graft can be seen through the skin.
Diameter and length work with it. A narrower cannula makes a smaller tunnel and allows finer layering, but it also raises injection pressure for the same fat, so the surgeon pushes harder. A longer shaft covers more of the recipient area from one entry point, which means fewer punctures. Matching all of this to the graft volume and the recipient site is the whole skill of the instrument choice.
| Material | German stainless steel |
| Opening | One sharpened opening at the tip |
| Tip | Tapered tip with a sharpened opening edge |
| Diameters | 1.0mm (19G), 1.1mm (19G), 1.2mm (18G), 1.4mm (17G), 1.5mm (17G), 1.6mm (16G), 1.8mm (15G), 2.0mm (14G), 2.4mm (13G), 2.5mm (13G), 3.0mm (11G) |
| Lengths | 3, 4, 5, 7, 7.5, 8, 9, 10, 12, 14, 15, 20, 25cm (by diameter) |
| Reusable | Yes — steam autoclavable to 134°C |
| Custom sizes | Available on request |
| Compliance | FDA CGMP, ISO 13485, ISO 9001, CE Mark |
The cannula is made from German stainless steel with a passivated surface that resists corrosion and pitting through repeated cleaning cycles. It is reusable and can be steam autoclaved at 134°C. Flush the lumen and the opening with clean water immediately after use and dry fully before autoclaving. The sharpened edge is the working surface, so inspect it under magnification at every cycle. A dulled edge tears tissue instead of cutting it, which is worse than a blunt opening rather than better.
Buying for your practice? Order online at factory-direct prices, straight from the manufacturer — no distributor markup.
Distributor, importer, or hospital group? Get bulk pricing, OEM manufacturing, and custom branding on the full cannula range.
Manufactured by Healermed Instruments, a surgical instruments manufacturer and exporter based in Sialkot, Pakistan. Factory-direct pricing removes the importer and distributor layer. Production runs under an ISO 13485 and FDA CGMP quality system, with ISO 9001 and CE Mark certification. OEM manufacturing and custom branding are available for distributor and brand-owner orders.
| Stainless Steel Luer Lock Injector Cannula All-steel hub for heavy autoclave cycles |
Super Luer Lock Injector Cannula Larger bore, longer thread, heavier hub |
| Universal Luer Lock Injector Cannula Fits Luer lock across syringe brands |
| Sharp Hole On Tip Extractor Injector Cannula All fittings on one page |
Sharp Hole On Tip Extractor Injector Cannulas The full category |
| Liposuction Cannulas Every cannula type and port pattern we make |
Liposuction Accessories Handles, hubs and cannulas for liposuction |
Healermed manufactures the full set of fat transfer and injector cannulas, alongside the wider liposuction cannulas and liposuction accessories range.
What is a sharp hole on tip injector cannula used for?
It is used to separate small volumes of fat and place them in fat transfer procedures. The sharpened opening at the tip cuts parcels on extraction and delivers a thread at the leading point on injection, which suits facial and touch-up grafting where one instrument doing both saves a change.
Can one cannula really both harvest and inject?
For small volumes, yes. A sharpened tip opening separates parcels as the cannula advances and delivers them as it withdraws. For large graft volumes a dedicated multiport harvester collects far faster; this instrument exists for cases where the volumes are small and changing instruments costs more time than it saves.
Is this cannula autoclavable?
Yes. The instrument is fully reusable and can be steam autoclaved at 134°C. Flush the lumen and opening with clean water immediately after use, before graft residue sets, and dry completely before sterilization.
Which fitting should I order?
All four fittings are Luer lock types. Standard Luer lock suits most grafting syringes; stainless steel Luer lock is for high sterilization throughput; Super Luer Lock has a larger bore for lower injection resistance; universal Luer lock seats across syringe brands where consumable stock varies.
What is the minimum order quantity for bulk orders?
The minimum order quantity is agreed per order rather than set at a fixed number. Send us the sizes, fittings and quantities you need through the wholesale request page and we will confirm the minimum for that specification.
Do you provide samples?
Yes. Samples are available on request and the buyer covers the shipping charges. Tell us the diameter and length you want to evaluate and we will confirm what can be sent. Testing a sample first is the fastest way to check hub fit against the syringes you inject with.
Can I order a custom size?
Yes. Custom diameters, working lengths and opening configurations are available on request in addition to the standard size grid. Send your specification through the wholesale request page and our production team will confirm what can be produced.