Liposuction Cannulas and Accessories › Two Parallel Ports One Central Port Liposuction Cannulas › Two Parallel Ports One Central Port Liposuction Cannula – MicroAire PAL Compatible
The Two Parallel Ports One Central Port Liposuction Cannula with MicroAire PAL Compatible fitting is a two parallel ports one central port liposuction cannula is a blunt-tip liposuction cannula with three grouped openings: two parallel ports nearest the tip and one central port set behind them. It is listed under Two Parallel Ports One Central Port Liposuction Cannulas, part of the Healermed Liposuction Cannulas and Accessories range.
Surgeons also refer to these liposuction cannulas as two parallel port cannulas, leading pair port cannulas, grouped three port lipo cannulas, or two-above-one port aspiration cannulas.
At a Glance
Power-assisted liposuction changes how force reaches the tissue. Instead of the surgeon pushing the cannula through the plane, the handpiece drives a short, fast reciprocating stroke and the cannula advances with far less applied force. In fibrous or previously operated tissue this reduces both surgeon fatigue and the effort needed for a controlled pass.
Three openings, arranged with the two parallel ports nearest the tip and the single central port set behind them. The count is the same as a central-port-first cannula; the order along the shaft is reversed, and that order is what changes how the instrument behaves in a pass.
With the pair leading, the widest part of the aperture reaches new tissue first. As the cannula advances, the two parallel ports open the plane across their span and the central port behind them works tissue that has already been engaged. Removal therefore starts wide and finishes narrow on every forward stroke, which spreads the draw across the front of the pass instead of concentrating it at a single leading opening.
The practical effect is a smoother entry into untreated tissue. A single leading port bites at one point and can pull the cannula toward it; two leading ports share that load between them, so the instrument tracks straighter as it advances and is less inclined to dig at the start of a stroke. Surgeons who work in long forward passes tend to prefer this order for that reason.
The trailing central port then acts as the finishing opening of the stroke, taking the last of the tissue the pair has opened. Total removal is roughly three times a single hole, held within a compact group so the surgeon can still judge how much has come from any one area. The distal tip is closed and rounded, separating the plane by blunt dissection while the vacuum works through the three ports rather than the end of the shaft.
| Material | German stainless steel |
| Fitting | MicroAire PAL power-assisted handpieces |
| Opening | Two parallel ports nearest the tip with one central port set behind them |
| Tip | Closed blunt tip |
| Diameters | 1.0mm (19G), 1.1mm (19G), 1.2mm (18G), 1.4mm (17G), 1.5mm (17G), 1.6mm (16G), 1.8mm (15G), 2.0mm (14G), 2.4mm (13G), 2.5mm (13G), 3.0mm (11G), 3.5mm (10G), 4.0mm (8G), 4.5mm (7G), 5.0mm (6G), 6.0mm (4G) |
| Lengths | 3, 4, 5, 7, 7.5, 8, 9, 10, 12, 14, 15, 20, 25, 30, 35cm (by diameter) |
| Reusable | Yes — steam autoclavable to 134°C |
| Custom sizes | Available on request |
| Compliance | FDA CGMP, ISO 13485, ISO 9001, CE Mark |
The cannula is made from German stainless steel with a passivated surface that resists corrosion and pitting through repeated cleaning cycles. It is reusable and can be steam autoclaved at 134°C. Flush the lumen and the opening with clean water immediately after use and dry fully before autoclaving. The three ports sit close together and at different points along the shaft, so turn the cannula while flushing and confirm water runs from all three before drying. Check each edge under light at every cycle, since the pattern only tracks straight while all three draw evenly.
Order this fitting only if you already own a PAL power-assisted handpiece; the hub will not fit a syringe or a manual handle. Diameter sets how much fat comes out per pass and length sets the reach. For body contouring of the abdomen, flanks and thighs, the 3.0mm to 4.0mm diameters in 25cm to 35cm are the usual working range and where the leading-pair order is most useful, since the passes are longest there. The 2.0mm to 2.5mm range in 15cm to 25cm covers arms, the neck and refinement work. The 1.0mm to 1.5mm diameters in 5cm to 12cm are for facial and submental contouring. Match the fitting to the syringe, vacuum line or handpiece already in your theater.
Buying for your practice? Order online at factory-direct prices, straight from the manufacturer — no distributor markup.
Distributor, importer, or hospital group? Get bulk pricing, OEM manufacturing, and custom branding on the full cannula range.
Manufactured by Healermed Instruments, a surgical instruments manufacturer and exporter based in Sialkot, Pakistan. Factory-direct pricing removes the importer and distributor layer. Production runs under an ISO 13485 and FDA CGMP quality system, with ISO 9001 and CE Mark certification. OEM manufacturing and custom branding are available for distributor and brand-owner orders.
Trademark notice: MicroAire and PAL are trademarks of MicroAire Surgical Instruments LLC. Healermed Instruments is not affiliated with, endorsed by, or sponsored by MicroAire. This cannula is an independently manufactured instrument and the compatibility reference is provided for the buyer's guidance only.
Every fitting below carries the same two parallel ports one central port shaft, the same closed blunt tip and the same size grid. Pick the one that matches the syringe, vacuum line or handpiece already in your theater.
| Luer Lock Liposuction Cannula Standard Luer lock syringes and suction tubing |
Stainless Steel Luer Lock Liposuction Cannula All-steel hub for heavy autoclave cycles |
| Super Luer Lock Liposuction Cannula Larger bore, longer thread, heavier hub |
Threaded Fitting Liposuction Cannula Threaded reusable handles and tubing connectors |
| Fixed Power Handle Liposuction Cannula Integrated handle, permanently attached |
Grooved Power Handle Liposuction Cannula Grooved grip for wet-glove control |
| Black Power Handle Liposuction Cannula Black anodized, low glare under lights |
Toomey Hub 60cc Liposuction Cannula 60cc Toomey-tip syringes, from 2.0mm up |
| Lumsail Compatible Liposuction Cannula Lumsail machine handpieces |
Universal Luer Lock Liposuction Cannula Fits Luer lock across syringe brands |
| Vibrasat Quick Lock Liposuction Cannula Vibrasat quarter-turn quick-lock coupling |
BeautiFill Laser Compatible Liposuction Cannula BeautiFill laser lipolysis handpieces |
Healermed manufactures the full range of cannulas for liposuction, from single hole finishing cannulas to high-flow debulking patterns, in 84 diameter and length combinations.
| Two Parallel Ports One Central Port Liposuction Cannula All 13 fittings on one product page |
Two Parallel Ports One Central Port Liposuction Cannulas The full two parallel ports one central port category |
| Liposuction Cannulas Every port pattern and cannula type we make |
Liposuction Accessories Handles, hubs and cannulas for liposuction |
What is a two parallel ports one central port liposuction cannula used for?
It is used to remove subcutaneous fat under vacuum during liposuction and body contouring. Two parallel ports nearest the tip lead each forward pass and spread the draw across its front, while the central port behind finishes the tissue they have opened, giving roughly three times the removal of a single hole in a compact group.
What is the difference between this and a one central port, two parallel ports cannula?
Both carry the same three openings. Here the parallel pair sits nearest the tip and the central port behind, so the widest part of the aperture meets new tissue first and the load is shared between two leading openings. On the central-port-first version a single opening leads, which gives a more defined aiming point but concentrates the draw at one place.
Is this cannula autoclavable?
Yes. The instrument is fully reusable and can be steam autoclaved at 134°C. Flush the lumen and the opening with clean water immediately after use, remove all residue before sterilization, and dry completely. Inspect the opening edge under light at every cycle, since edge condition decides how the cannula behaves in tissue.
Which size should I use?
For body contouring of the abdomen, flanks and thighs, 3.0mm to 4.0mm diameters in 25cm to 35cm are the usual range and where the leading-pair order helps most, since the passes are longest there. Arms, neck and refinement work suit 2.0mm to 2.5mm in 15cm to 25cm. Facial and submental contouring uses 1.0mm to 1.5mm in 5cm to 12cm.
What is the minimum order quantity for bulk orders?
The minimum order quantity is agreed per order rather than set at a fixed number. Send us the sizes, fittings and quantities you need through the wholesale request page and we will confirm the minimum for that specification. This lets a small distributor start with a trial order and a larger importer scale up on the same terms.
Do you provide samples?
Yes. Samples are available on request and the buyer covers the shipping charges. Send us your handpiece details with the diameter and length you want to evaluate. Testing a sample in your own handpiece before a bulk order is strongly recommended for any powered fitting.
Can I order a custom size?
Yes. Custom diameters, working lengths and opening dimensions are available on request in addition to the standard size grid. Send your specification through the wholesale request page and our production team will confirm what can be produced. Custom branding is also available for distributor and OEM orders.