Tumescent Infiltration Cannula – Universal Luer Lock

Universal Luer lock tumescent infiltration cannula, German stainless steel
Universal Luer lock tumescent infiltration cannula, German stainless steel
Universal Luer lock tumescent infiltration cannula, German stainless steel
Universal Luer lock tumescent infiltration cannula, German stainless steel
Tumescent Infiltration Cannula – Universal Luer Lock
The Tumescent Infiltration Liposuction Cannula with Universal Luer Lock is a blunt-tip, multi-hole cannula whose hub is machined to seat correctly across the range of Luer lock syringes and tubing sets found in most theaters. It delivers tumescent or... Read More
$8.00

Available Options

Direct Manufacturer B2B / OEM

Buy Online

Add to Cart Now

Bulk & Wholesale

Volume pricing & private label

Factory Quote

Logo & Name Engraving

FREE

Add your logo or name in checkout notes

Guide

Custom Sizes

Any length, curvature, or modification — to your spec

Request

Certified Quality

Globally certified & registered manufacturer

  • FDA · cGMPUS Registered & GMP Compliant
  • CE MarkingEU MDR Compliant
  • ISO 13485Medical Devices QMS
  • ISO 9001Quality Management
  • EUDAMEDEU Registered
SSL SECURED

Your Security, Our Priority

Globally trusted & secured payment methods

  • PayPal
  • Visa / Mastercard
  • Apple Pay
  • Google Pay
  • Bank transfer

The Tumescent Infiltration Liposuction Cannula with Universal Luer Lock is a blunt-tip, multi-hole cannula whose hub is machined to seat correctly across the range of Luer lock syringes and tubing sets found in most theaters. It delivers tumescent or wetting solution into the subcutaneous plane before liposuction. Buyers choose this fitting when their consumable supply changes brand between orders and a hub that only seats well on one brand becomes a daily problem. See the full Tumescent Infiltration Liposuction Cannulas range for other fittings.

Buyers also search for this instrument as a universal luer tumescent cannula, a multi-fit luer lock infiltrator, or a standard luer wetting solution cannula.

At a Glance

  • Instrument type: Multi-hole tumescent infiltration cannula, reusable
  • Fitting: Universal Luer lock hub — fits across syringe and tubing brands
  • Hole pattern: Many small round holes staggered along the working length
  • Tip: Closed blunt tip
  • Diameters: 1.0mm (19G) to 6.0mm (4G)
  • Working lengths: 3cm to 35cm
  • Material: German stainless steel
  • Sterilization: Steam autoclavable to 134°C
  • Manufacturer: Healermed Instruments, Sialkot, Pakistan

Universal Luer Lock Hub for Mixed Syringe and Tubing Stock

Luer lock is a standard, but manufacturing tolerances differ between brands, and a hub cut to the tight end of the tolerance band can seat poorly on some syringes. A universal hub is machined to sit centrally in that band, so it locks properly across whatever stock is on the shelf that week. For a clinic buying consumables from more than one supplier, this removes a recurring irritation.

How the Port Pattern Works

The working section carries many small round holes spread in a staggered pattern along the shaft rather than grouped near the tip. Each hole releases a small share of the solution, so a single pass wets a long column of tissue evenly instead of pooling fluid at one point. The staggered layout means the openings do not sit in one straight line, so solution leaves the shaft on more than one side and spreads through the plane rather than tracking along a single channel.

The distal tip is closed and rounded. It separates the subcutaneous plane by blunt dissection as the cannula advances, pushing vessels and nerves aside rather than dividing them, which is why an infiltration cannula is not simply a long needle.

Key Features

  • Universal Luer lock hub seats correctly across syringe and tubing brands
  • Threaded lock connection holds under manual and pump pressure
  • Many small holes in a staggered pattern along the working length
  • Even wetting of a long tissue column in a single pass
  • Closed blunt tip separates the plane without cutting vessels or nerves
  • One-piece German stainless steel shaft, fully reusable
  • Custom diameters, lengths and hole patterns available on request

Specifications

Material German stainless steel
Fitting Universal Luer lock
Hole pattern Many small round holes staggered along the working length
Tip Closed blunt tip
Diameters 1.0mm (19G), 1.1mm (19G), 1.2mm (18G), 1.4mm (17G), 1.5mm (17G), 1.6mm (16G), 1.8mm (15G), 2.0mm (14G), 2.4mm (13G), 2.5mm (13G), 3.0mm (11G), 3.5mm (10G), 4.0mm (8G), 4.5mm (7G), 5.0mm (6G), 6.0mm (4G)
Lengths 3, 4, 5, 7, 7.5, 8, 9, 10, 12, 14, 15, 20, 25, 30, 35cm (by diameter)
Reusable Yes — steam autoclavable to 134°C
Custom sizes Available on request
Compliance FDA CGMP, ISO 13485, ISO 9001, CE Mark

Clinical Applications

  • Tumescent infiltration before body liposuction of the abdomen, flanks, back and thighs
  • Wetting solution delivery before power-assisted and syringe liposuction
  • Arm, neck and submental infiltration with the shorter, smaller-diameter sizes
  • Donor site infiltration before fat harvesting for grafting

Material and Sterilization

The cannula is made from German stainless steel with a passivated surface that resists corrosion and pitting through repeated cleaning cycles. It is reusable and can be steam autoclaved at 134°C. Flush the lumen and every hole with clean water immediately after use and dry fully before autoclaving. A cannula with many small openings needs more attention here than a two-port design, because dried tumescent solution blocks small holes first and an uneven port flow shows up as uneven infiltration.

How to Choose

Choose the universal hub if your syringe stock varies by brand or you supply a hospital group buying consumables centrally; if you use one brand consistently, the standard Luer lock version does the same job. Diameter sets the flow rate and length sets the reach. For large-volume body infiltration of the abdomen, flanks, back and thighs, the 2.5mm to 4.0mm diameters in 25cm to 35cm are the usual working range, because they fill a large area in fewer passes. The 1.8mm to 2.5mm range in 15cm to 25cm suits arms, the neck and smaller regions. The 1.0mm to 1.5mm diameters in 5cm to 12cm are for facial and submental infiltration, where thin tissue needs a small-diameter cannula. Match the fitting to the syringe, pump or handpiece already in your theater.

Buying for your practice? Order online at factory-direct prices, straight from the manufacturer — no distributor markup.

Shop Online

Distributor, importer, or hospital group? Get bulk pricing, OEM manufacturing, and custom branding on the full cannula range.

Request Wholesale Price

Why Buy Direct From the Manufacturer

Manufactured by Healermed Instruments, a surgical instruments manufacturer and exporter based in Sialkot, Pakistan. Factory-direct pricing removes the importer and distributor layer. Production runs under an ISO 13485 and FDA CGMP quality system, with ISO 9001 and CE Mark certification. OEM manufacturing and custom branding are available for distributor and brand-owner orders.

Related Instruments

Other fittings in the same cannula range:

Frequently Asked Questions

What is a universal Luer lock tumescent cannula used for?

It is used to deliver tumescent or wetting solution into subcutaneous tissue before liposuction, with a hub machined to seat correctly across different syringe and tubing brands. Clinics that buy consumables from more than one supplier choose it so the same cannula works with whatever stock arrives.

What is the difference between a tumescent infiltration cannula and an aspiration cannula?

An infiltration cannula delivers fluid into tissue; an aspiration cannula removes fat under vacuum. Infiltration cannulas are narrower, carry many small holes for even fluid spread, and connect to a syringe or pump. Aspiration cannulas have fewer, much larger ports designed to draw fat and connect to a vacuum line.

Why does this cannula have so many holes?

Many small holes spread the solution along the whole length of the pass instead of releasing it at one point. That gives a more even wetting of the treatment area, fewer passes to fill a large region, and less risk of a fluid pocket forming where a single port sat. The staggered layout also sends solution out on more than one side of the shaft.

Is this cannula autoclavable?

Yes. The instrument is fully reusable and can be steam autoclaved at 134°C. Flush the lumen and every hole with clean water immediately after use, remove all residue before sterilization, and dry completely. Check the holes under light before each cycle, since a blocked opening changes how the solution distributes on the next case.

What is the minimum order quantity for bulk orders?

The minimum order quantity is agreed per order rather than set at a fixed number. Send us the sizes, fittings and quantities you need through the wholesale request page and we will confirm the minimum for that specification. This lets a small distributor start with a trial order and a larger importer scale up on the same terms.

Do you provide samples?

Yes. Samples are available on request and the buyer covers the shipping charges. Tell us the diameter and length you want to evaluate and we will confirm what can be sent. Testing a sample against the syringe brands you actually stock confirms the universal hub fits your supply.

Can I order a custom size?

Yes. Custom diameters, working lengths, and hole patterns are available on request in addition to the standard size grid. Send your specification through the wholesale request page and our production team will confirm what can be produced. Custom branding is also available for distributor and OEM orders.

Brand: Healermed instruments Model: ENT-WB3-12
The Weil-Blakesley Nasal Ethmoid Forceps are premium-grade ENT surgical instruments engineered for high-precision rhinology and sinus procedures. Feat..
$25.00
Add to Cart
Brand: Healermed instruments Model: PS-TD-SC
Achieve unparalleled precision in advanced plastic surgery with our premium-grade Tebbetts Delicate SuperCut Dissecting Scissors. Specifically enginee..
$14.00
Add to Cart
Brand: Healermed instruments Model: HMI-STV-BSC
Achieve unparalleled precision in intricate procedures with the BlackTiCer™ Series Serrated Stevens Tenotomy Scissors. Specifically engineered for spe..
$16.00
Add to Cart
Brand: Healermed instruments Model: HM-PYR-ULL
The Pyramid Hole Liposuction Cannula with Universal Luer Lock is a blunt-tip aspiration cannula with one upper hole and two parallel holes below, whos..
$8.00
Add to Cart
Brand: Healermed instruments Model: OP-SB-01
Equip your facility with premium-grade Sharp/Blunt Operating Scissors, a foundational surgical instrument engineered for versatile cutting performance..
$6.00
Add to Cart
Brand: Healermed instruments Model: HM-C2P-MA
The MicroAire PAL Compatible Cobra Style Two Port Liposuction Cannula is a blunt-tip aspiration cannula with two side ports and a hub built to fit Mic..
$45.00
Add to Cart
Brand: Healermed instruments Model: HM-SGG-9060
The Sheen Graft Grid is a specialized measuring instrument used for precise sizing, trimming, and orientation of cartilage grafts in rhinoplasty and f..
$12.00
Add to Cart
Brand: Healermed instruments Model: HM-ATC-TF
The Angled Tumescent Infiltration Cannula with Threaded Fitting is a blunt-tip cannula with a bent working shaft, used to deliver tumescent or wetting..
$15.00
Add to Cart
Healermed Support
Sales Agent · Online

Chat on WhatsApp