The 3 Spiral Port Liposuction Cannula with Luer Lock fitting is a blunt-tip aspiration cannula whose three ports are stepped along the shaft and rotated in a spiral, used to remove subcutaneous fat under vacuum during liposuction. The Luer lock hub screws onto standard Luer lock syringes and suction tubing, so the connection holds under vacuum instead of pulling off mid-pass. It is listed under 3 Spiral Port Liposuction Cannulas, part of the Healermed Liposuction Cannulas and Accessories range.
Surgeons also refer to this instrument as a Luer lock Carraway cannula, a spiral port lipo cannula, or a three port spiral aspiration cannula.
At a Glance
The Luer lock is the most common connection in aesthetic surgery. A threaded collar screws onto the syringe or tubing set and holds the joint closed under vacuum, where a slip fit can pull apart. In syringe-assisted liposuction that matters, because a disconnection breaks the vacuum and interrupts the pass.
The three ports are not grouped at one point on the shaft. They are stepped along it and rotated around it, so each opening sits further back and turned to a different side than the one before — a spiral rather than a cluster. That layout is the whole difference between this cannula and a Mercedes tip, where the three ports sit level with each other around the circumference.
The effect shows up in the tunnel the cannula leaves. With the ports level, one pass draws from one narrow band of tissue, and even coverage depends on the surgeon laying the passes side by side accurately. With the ports spiralled, a single pass takes a little from three different depths and directions at once, so the tunnel is wider and less sharply defined. Adjacent passes overlap more readily and the transitions between them are softer.
That is why a spiral pattern is chosen where a visible tunnel line would be a problem: in the superficial layer, over the flanks and back, and in thin or previously operated tissue. It removes at a moderate rate rather than a fast one, and gives back a more forgiving result at the edges.
The distal tip is closed and rounded. It separates the plane by blunt dissection as the cannula advances, pushing vessels and nerves aside rather than dividing them, and the vacuum works through the three spiral ports rather than the end of the shaft.
| Material | German stainless steel |
| Fitting | Luer lock |
| Port pattern | 3 spiral ports, Carraway style — stepped along the shaft and rotated |
| Tip | Closed blunt tip |
| Diameters | 1.0mm (19G), 1.1mm (19G), 1.2mm (18G), 1.4mm (17G), 1.5mm (17G), 1.6mm (16G), 1.8mm (15G), 2.0mm (14G), 2.4mm (13G), 2.5mm (13G), 3.0mm (11G), 3.5mm (10G), 4.0mm (8G), 4.5mm (7G), 5.0mm (6G), 6.0mm (4G) |
| Lengths | 3, 4, 5, 7, 7.5, 8, 9, 10, 12, 14, 15, 20, 25, 30, 35cm (by diameter) |
| Reusable | Yes — steam autoclavable to 134°C |
| Custom sizes | Available on request |
| Compliance | FDA CGMP, ISO 13485, ISO 9001, CE Mark |
The cannula is made from German stainless steel with a passivated surface that resists corrosion and pitting through repeated cleaning cycles. It is reusable and can be steam autoclaved at 134°C. Flush the lumen and all three ports with clean water immediately after use and dry fully before autoclaving. Because the ports sit at different points along the shaft, turn the cannula while flushing so water passes through each one, and check every opening under light before sterilization.
Diameter sets how much fat comes out per pass and length sets the reach. For body contouring of the abdomen, flanks, back and thighs, the 3.0mm to 4.0mm diameters in 25cm to 35cm are the usual working range, and this is where the spiral pattern earns its place because those are the areas where tunnel lines show. The 2.0mm to 2.5mm range in 15cm to 25cm covers arms, the neck and superficial work. The 1.0mm to 1.5mm diameters in 5cm to 12cm are for facial and submental contouring. Match the fitting to the syringe, vacuum line or handpiece already in your theater.
Buying for your practice? Order online at factory-direct prices, straight from the manufacturer — no distributor markup.
Distributor, importer, or hospital group? Get bulk pricing, OEM manufacturing, and custom branding on the full cannula range.
Manufactured by Healermed Instruments, a surgical instruments manufacturer and exporter based in Sialkot, Pakistan. Factory-direct pricing removes the importer and distributor layer. Production runs under an ISO 13485 and FDA CGMP quality system, with ISO 9001 and CE Mark certification. OEM manufacturing and custom branding are available for distributor and brand-owner orders.
Other fittings in the same cannula range:
What is a Luer lock 3 spiral port liposuction cannula used for?
It is used to remove subcutaneous fat under vacuum during liposuction, with a threaded hub that screws onto a standard Luer lock syringe or suction tubing set. The three spiral ports draw from several depths and angles per pass, so adjacent passes blend without leaving a tunnel line.
What is the difference between a spiral port and a Mercedes tip cannula?
On a Mercedes tip the three ports sit level with each other around the shaft; on a spiral port cannula they are stepped along the shaft and rotated, so each sits at a different point and angle. Mercedes clears faster from a narrow band; the spiral pattern draws from a wider, softer-edged band and blends between passes more easily.
Is this cannula autoclavable?
Yes. The instrument is fully reusable and can be steam autoclaved at 134°C. Flush the lumen and all three ports with clean water immediately after use, turning the cannula so water passes through each one, then dry completely before sterilization. Inspect every opening each cycle, since the pattern depends on all three drawing evenly.
What is the minimum order quantity for bulk orders?
The minimum order quantity is agreed per order rather than set at a fixed number. Send us the sizes, fittings and quantities you need through the wholesale request page and we will confirm the minimum for that specification. This lets a small distributor start with a trial order and a larger importer scale up on the same terms.
Do you provide samples?
Yes. Samples are available on request and the buyer covers the shipping charges. Tell us the diameter and length you want to evaluate and we will confirm what can be sent. Testing a sample first is the fastest way to check port edge finish and hub fit against your own syringes.
Can I order a custom size?
Yes. Custom diameters, working lengths and port configurations are available on request in addition to the standard size grid. Send your specification through the wholesale request page and our production team will confirm what can be produced. Custom branding is also available for distributor and OEM orders.