The Angled Tumescent Infiltration Cannula with Super Luer Lock is a blunt-tip cannula with a bent working shaft, used to deliver tumescent or wetting solution before liposuction. The Super Luer Lock hub is built with a larger bore, a longer thread and a heavier hub body than a standard Luer lock, so it carries more flow and holds its grip under sustained pump pressure. See the full Angled Tumescent Infiltration Cannulas range for other fittings.
Buyers also search for this instrument as a super luer angled cannula, a high-flow bent infiltrator, or a reinforced luer lock tumescent cannula.
At a Glance
Infiltration speed is limited by the narrowest point in the fluid path. On a full body case the surgeon may deliver several litres of tumescent solution, and a standard Luer hub can become that limiting point. The Super Luer Lock hub uses a larger internal bore, with a longer thread on a heavier body so the connection stays tight under sustained pump pressure.
An angled cannula has a bend in the shaft, so the working section travels at an angle to the hub axis instead of running straight back from it. That changes the direction of the pass itself, which is the difference between an angled cannula and a bayonet one: a bayonet steps the shaft sideways and then runs parallel again, while an angle redirects where the tip actually goes.
The practical gain is reach. The body is curved, and a straight cannula entering a flank, hip or submental area has to be forced to an awkward wrist position to stay in the subcutaneous plane as the surface falls away. An angled shaft follows that curve instead of fighting it, so a single entry port covers more area and the surgeon's wrist stays in a neutral position through the pass.
The second gain is clearance at the skin. Because the hub sits at an angle rather than flat against the surface, the syringe or handpiece is held up and away from the area being filled. The surgeon is not pressing on tissue that is in the middle of taking up solution, which makes it easier to read turgor as the endpoint approaches.
The distal tip is closed and rounded. It separates the subcutaneous plane by blunt dissection as the cannula advances, pushing vessels and nerves aside rather than dividing them, and side holes along the working section release the solution along the length of the pass rather than at one point.
| Material | German stainless steel |
| Fitting | Super Luer Lock — larger bore, longer thread, heavier hub |
| Shaft shape | Angled — working section bent away from the hub axis |
| Tip | Closed blunt tip with side holes |
| Diameters | 1.0mm (19G), 1.1mm (19G), 1.2mm (18G), 1.4mm (17G), 1.5mm (17G), 1.6mm (16G), 1.8mm (15G), 2.0mm (14G), 2.4mm (13G), 2.5mm (13G), 3.0mm (11G), 3.5mm (10G), 4.0mm (8G), 4.5mm (7G), 5.0mm (6G), 6.0mm (4G) |
| Lengths | 3, 4, 5, 7, 7.5, 8, 9, 10, 12, 14, 15, 20, 25, 30, 35cm (by diameter) |
| Reusable | Yes — steam autoclavable to 134°C |
| Custom sizes | Available on request |
| Compliance | FDA CGMP, ISO 13485, ISO 9001, CE Mark |
The cannula is made from German stainless steel with a passivated surface that resists corrosion and pitting through repeated cleaning cycles. It is reusable and can be steam autoclaved at 134°C. Flush the lumen and every side hole with clean water immediately after use and dry fully before autoclaving. On an angled cannula, flush from both ends: any bend in a lumen is where residue settles first, and a partly blocked shaft changes how the solution distributes on the next case.
Diameter sets the flow rate and length sets the reach. For large body areas such as the abdomen, flanks and thighs, the 2.5mm to 4.0mm diameters in 25cm to 35cm are the usual working range, because they fill a large area in fewer passes. The 1.8mm to 2.5mm range in 15cm to 25cm suits arms, the neck and smaller regions, where the angle earns the most because the surface curves sharply. The 1.0mm to 1.5mm diameters in 5cm to 12cm are for facial and submental infiltration. Match the fitting to the syringe, pump or handpiece already in your theater.
Buying for your practice? Order online at factory-direct prices, straight from the manufacturer — no distributor markup.
Distributor, importer, or hospital group? Get bulk pricing, OEM manufacturing, and custom branding on the full cannula range.
Manufactured by Healermed Instruments, a surgical instruments manufacturer and exporter based in Sialkot, Pakistan. Factory-direct pricing removes the importer and distributor layer. Production runs under an ISO 13485 and FDA CGMP quality system, with ISO 9001 and CE Mark certification. OEM manufacturing and custom branding are available for distributor and brand-owner orders.
Other fittings in the same cannula range:
What is a Super Luer Lock angled cannula used for?
It is used for high-volume tumescent infiltration where flow rate matters, typically with a pump rather than a hand syringe. The larger bore carries more fluid per second and the longer thread holds a firm connection under sustained pressure, while the angled shaft follows the curve of the treatment area.
What is the difference between an angled cannula and a straight cannula?
An angled cannula has a bend in the shaft, so the working section travels at an angle to the hub; a straight cannula runs in one line. The angle lets the cannula follow a curved body surface and stay in the subcutaneous plane without the surgeon twisting the wrist. A straight cannula is simpler to clean and store.
Is this cannula autoclavable?
Yes. The instrument is fully reusable and can be steam autoclaved at 134°C. Flush the lumen and every side hole with clean water immediately after use, remove all residue before sterilization, and dry completely. Flush from both ends so nothing is left sitting in the bend, where residue collects first.
What is the minimum order quantity for bulk orders?
The minimum order quantity is agreed per order rather than set at a fixed number. Send us the sizes, fittings and quantities you need through the wholesale request page and we will confirm the minimum for that specification. This lets a small distributor start with a trial order and a larger importer scale up on the same terms.
Do you provide samples?
Yes. Samples are available on request and the buyer covers the shipping charges. Tell us the diameter and length you want to evaluate and we will confirm what can be sent. Testing a sample first confirms the hub seats correctly in your existing tubing set.
Can I order a custom size?
Yes. Custom diameters, working lengths, bend angles and hole patterns are available on request in addition to the standard size grid. Send your specification through the wholesale request page and our production team will confirm what can be produced. Custom branding is also available for distributor and OEM orders.