The 6 Spiral Port Liposuction Cannula is a blunt-tip aspiration cannula whose six ports are stepped along the shaft and rotated around it rather than grouped at one point. It is used to remove subcutaneous fat under vacuum during liposuction and body contouring, and is chosen for the debulking stage over large areas where pass count needs to stay manageable. It sits in the 6 Spiral Port Liposuction Cannulas category, part of the wider Healermed Liposuction Cannulas and Accessories range, and is supplied in 11 hub and handle fittings and 84 diameter and length combinations worldwide.
Surgeons also refer to these instruments as six port lipo cannulas, spiral port aspiration cannulas, six hole liposuction cannulas, or helical port cannulas.
At a Glance
On a large area the limit is not how well the surgeon can shape tissue, it is how many passes the case will take. Every extra pass is time under anaesthesia and more fatigue in the hand that has to keep them even. The six spiral port pattern exists to reduce that count without going back to a hard-edged tunnel.
Six ports are stepped along the shaft and rotated around it, each one set further back and turned to a different side than the one before. It is the same spiral principle as the three port version, extended: twice the openings, spread over a longer stretch of shaft and covering more of the circumference.
The result is a wider draw band and a faster one. Each pass takes fat from six points at different depths and angles instead of three, so a given area is cleared in fewer passes and the tunnel it leaves is broader and less sharply defined. Adjacent passes overlap heavily, which is what keeps the transitions soft across a large surface.
The trade against the three port version is control. Six openings remove more per stroke, so there is less margin to stop at exactly the right point. That makes this the cannula for the debulking stage over large areas — abdomen, back, outer thighs — and makes the three port version the better choice once the shape is close and the work moves to blending. Many surgeons carry both and switch as the case progresses.
The distal tip is closed and rounded. It separates the plane by blunt dissection as the cannula advances, pushing vessels and nerves aside rather than dividing them, and the vacuum works through the six spiral ports rather than the end of the shaft.
| Fitting | Connects to |
| Luer Lock | Standard Luer lock syringes and suction tubing |
| Stainless Steel Luer Lock | Same as Luer lock, all-steel hub for heavy autoclave cycles |
| Super Luer Lock | Luer connection with a larger bore, longer thread and heavier hub |
| Threaded Fitting | Threaded reusable handles and tubing connectors |
| Fixed Power Handle | Integrated handle, permanently attached to the shaft |
| Grooved Power Handle | Grooved grip handle for controlled passes |
| Black Power Handle | Black anodized handle, reduced glare under operating lights |
| Toomey Hub, 60cc | 60cc Toomey-tip syringes, available from 2.0mm upward |
| MicroAire PAL Compatible | MicroAire PAL power-assisted handpieces |
| Lumsail Compatible | Lumsail machine handpieces |
| Universal Luer Lock | Luer lock hub built to fit across syringe brands |
| BeautiFill Laser Compatible | BeautiFill laser lipolysis handpieces |
| Vibrasat Quick Lock | Vibrasat power-assisted handpieces with quick-lock coupling |
| Material | German stainless steel |
| Port pattern | 6 spiral ports — stepped along the shaft and rotated |
| Tip | Closed blunt tip |
| Diameters | 1.0mm (19G), 1.1mm (19G), 1.2mm (18G), 1.4mm (17G), 1.5mm (17G), 1.6mm (16G), 1.8mm (15G), 2.0mm (14G), 2.4mm (13G), 2.5mm (13G), 3.0mm (11G), 3.5mm (10G), 4.0mm (8G), 4.5mm (7G), 5.0mm (6G), 6.0mm (4G) |
| Lengths | 3, 4, 5, 7, 7.5, 8, 9, 10, 12, 14, 15, 20, 25, 30, 35cm (by diameter) |
| Fittings | 11 hub and handle types |
| Reusable | Yes — steam autoclavable to 134°C |
| Custom sizes | Available on request |
| Compliance | FDA CGMP, ISO 13485, ISO 9001, CE Mark |
The cannula is made from German stainless steel with a passivated surface that resists corrosion and pitting through repeated cleaning cycles. It is reusable and can be steam autoclaved at 134°C. Flush the lumen and all six ports with clean water immediately after use and dry fully before autoclaving. Because the ports sit at different points along the shaft, turn the cannula while flushing so water passes through each one, and check every opening under light — with six ports there are more places for residue to sit than on any other pattern in the range.
Diameter sets how much fat comes out per pass and length sets the reach. The six port pattern is built for area, so the 3.5mm to 5.0mm diameters in 30cm to 35cm are the core working range for abdomen, back and outer thighs. The 3.0mm in 25cm to 30cm suits flanks and smaller body areas. Below 2.5mm the six port pattern has little advantage over the three port version, so for arms, neck and superficial work choose the 3 spiral port cannula instead. Match the fitting to the syringe, vacuum line or handpiece already in your theater.
Buying for your practice? Order online at factory-direct prices, straight from the manufacturer — no distributor markup.
Distributor, importer, or hospital group? Get bulk pricing, OEM manufacturing, and custom branding on the full cannula range.
Manufactured by Healermed Instruments, a surgical instruments manufacturer and exporter based in Sialkot, Pakistan. Factory-direct pricing removes the importer and distributor layer. Production runs under an ISO 13485 and FDA CGMP quality system, with ISO 9001 and CE Mark certification. OEM manufacturing and custom branding are available for distributor and brand-owner orders.
Choose the fitting that matches your equipment:
What is a 6 spiral port liposuction cannula used for?
It is used to remove subcutaneous fat under vacuum during liposuction and body contouring, in the debulking stage over large areas. Six ports stepped along the shaft and rotated give a wide draw band, so a big surface is cleared in fewer passes while adjacent passes still overlap and blend.
What is the difference between a 6 spiral port and a 3 spiral port cannula?
Both use the same spiral principle, with ports stepped along the shaft and rotated. The six port version has twice the openings over a longer stretch, so it clears fat faster across a wider band and suits debulking large areas. The three port version removes more slowly and gives more control, which suits blending and superficial work.
Is this cannula autoclavable?
Yes. The instrument is fully reusable and can be steam autoclaved at 134°C. Flush the lumen and all six ports with clean water immediately after use, turning the cannula so water passes through each one, then dry completely before sterilization. Inspect every opening each cycle, since the pattern depends on all six drawing evenly.
What is the minimum order quantity for bulk orders?
The minimum order quantity is agreed per order rather than set at a fixed number. Send us the sizes, fittings and quantities you need through the wholesale request page and we will confirm the minimum for that specification. This lets a small distributor start with a trial order and a larger importer scale up on the same terms.
Which size should I use?
The 3.5mm to 5.0mm diameters in 30cm to 35cm are the core working range for abdomen, back and outer thighs. Use 3.0mm in 25cm to 30cm for flanks and smaller body areas. Below 2.5mm the six port pattern gives little advantage, so for arms, neck and superficial work choose the 3 spiral port version instead.
Do you provide samples?
Yes. Samples are available on request and the buyer covers the shipping charges. Tell us the diameter, length and fitting you want to evaluate and we will confirm what can be sent. Testing a sample before a bulk order is the fastest way to check port edge finish and hub fit against your own equipment.
Can I order a custom size?
Yes. Custom diameters, working lengths and port configurations are available on request in addition to the standard size grid. Send your specification through the wholesale request page and our production team will confirm what can be produced. Custom branding is also available for distributor and OEM orders.