Buy Online
Add to Cart Now
Your shopping cart is empty!
Lorem Ipsum is simply dummy text of the printing and typesetting industry.
Globally certified & registered manufacturer
Globally trusted & secured payment methods
Liposuction Cannulas and Accessories › Double Long Port Liposuction Cannulas › Double Long Port Liposuction Cannula – Grooved Power Handle
The Double Long Port Liposuction Cannula with Grooved Power Handle fitting is a double long port liposuction cannula is a blunt-tip liposuction cannula with two long ports cut along the shaft, used to remove subcutaneous fat under vacuum during liposuction and body contouring. Each long port draws along its whole run instead of from a point, so one pass clears a defined lane at a steady, controllable rate. It is listed under Double Long Port Liposuction Cannulas, part of the Healermed Liposuction Cannulas and Accessories range.
Surgeons also refer to these liposuction cannulas as two long port cannulas, double port lipo cannulas, long aperture aspiration cannulas, or twin long port liposuction cannulas.
At a Glance
Grip loss is a practical problem in liposuction, not a cosmetic one. A full case is hundreds of repeated strokes against tissue resistance with wet gloves, and a slipping hand changes the depth and direction of the pass. On a directional cannula the grip also holds the aperture pointing at the layer being worked.
Two long ports, cut along the shaft rather than drilled as round holes. Port length is what separates this liposuction cannula from a two-hole design, and it changes both how fast it works and how the draw feels through the handle.
A round hole takes from a point. Fat is pulled sideways into a small opening, parts against a tight curve, and the draw stops and restarts as each hole clears and blocks again. A long port draws along its whole run instead, so tissue enters as a continuous column in the direction the cannula is already travelling. Two of those roughly double the effect.
The practical result is a lane cleared per pass rather than a line of spots, at a rate that suits the main working phase of a case. It is faster than any two-hole cannula of the same diameter, and steadier, because a long aperture is far less prone to the surging that small ports produce in thick aspirate.
Two openings rather than four or six is the restraint that keeps it usable. The surgeon still knows where the fat is leaving and can stop when the contour is right, which is not true of a multi-port debulking cannula. The distal tip is closed and rounded, separating the plane by blunt dissection while the vacuum works through the two long side ports rather than the end of the shaft.
| Material | German stainless steel |
| Fitting | Grooved grip for wet-glove control |
| Opening | Two long ports on the shaft |
| Tip | Closed blunt tip |
| Diameters | 1.0mm (19G), 1.1mm (19G), 1.2mm (18G), 1.4mm (17G), 1.5mm (17G), 1.6mm (16G), 1.8mm (15G), 2.0mm (14G), 2.4mm (13G), 2.5mm (13G), 3.0mm (11G), 3.5mm (10G), 4.0mm (8G), 4.5mm (7G), 5.0mm (6G), 6.0mm (4G) |
| Lengths | 3, 4, 5, 7, 7.5, 8, 9, 10, 12, 14, 15, 20, 25, 30, 35cm (by diameter) |
| Reusable | Yes — steam autoclavable to 134°C |
| Custom sizes | Available on request |
| Compliance | FDA CGMP, ISO 13485, ISO 9001, CE Mark |
The cannula is made from German stainless steel with a passivated surface that resists corrosion and pitting through repeated cleaning cycles. It is reusable and can be steam autoclaved at 134°C. Flush the lumen and the opening with clean water immediately after use and dry fully before autoclaving. Two long ports mean two long edges doing all the work, so run a light along the full length of both openings at each cycle rather than glancing at them. A long aperture also holds more residue than a small port, so flush from the hub until the water runs clear.
Choose the grooved handle for long cases and large surface areas where hand fatigue and grip slip build up; for short refinement work a smooth fixed handle is usually enough. Diameter sets how much fat comes out per pass and length sets the reach. For body contouring of the abdomen, flanks, back and thighs, the 3.0mm to 4.0mm diameters in 25cm to 35cm are the usual working range and where this pattern is used most. The 2.0mm to 2.5mm range in 15cm to 25cm covers arms, the neck and refinement work. The 1.0mm to 1.5mm diameters in 5cm to 12cm are for facial and submental contouring. For final shaping choose a single-hole or short-hole cannula, which removes far less per pass. Match the fitting to the syringe, vacuum line or handpiece already in your theater.
Buying for your practice? Order online at factory-direct prices, straight from the manufacturer — no distributor markup.
Distributor, importer, or hospital group? Get bulk pricing, OEM manufacturing, and custom branding on the full cannula range.
Manufactured by Healermed Instruments, a surgical instruments manufacturer and exporter based in Sialkot, Pakistan. Factory-direct pricing removes the importer and distributor layer. Production runs under an ISO 13485 and FDA CGMP quality system, with ISO 9001 and CE Mark certification. OEM manufacturing and custom branding are available for distributor and brand-owner orders.
Every fitting below carries the same double long port shaft, the same closed blunt tip and the same size grid. Pick the one that matches the syringe, vacuum line or handpiece already in your theater.
| Luer Lock Liposuction Cannula Standard Luer lock syringes and suction tubing |
Stainless Steel Luer Lock Liposuction Cannula All-steel hub for heavy autoclave cycles |
| Super Luer Lock Liposuction Cannula Larger bore, longer thread, heavier hub |
Threaded Fitting Liposuction Cannula Threaded reusable handles and tubing connectors |
| Fixed Power Handle Liposuction Cannula Integrated handle, permanently attached |
Black Power Handle Liposuction Cannula Black anodized, low glare under lights |
| Toomey Hub 60cc Liposuction Cannula 60cc Toomey-tip syringes, from 2.0mm up |
MicroAire PAL Compatible Liposuction Cannula MicroAire PAL power-assisted handpieces |
| Lumsail Compatible Liposuction Cannula Lumsail machine handpieces |
Universal Luer Lock Liposuction Cannula Fits Luer lock across syringe brands |
| Vibrasat Quick Lock Liposuction Cannula Vibrasat quarter-turn quick-lock coupling |
BeautiFill Laser Compatible Liposuction Cannula BeautiFill laser lipolysis handpieces |
Healermed manufactures the full range of cannulas for liposuction, from single hole finishing cannulas to high-flow debulking patterns, in 84 diameter and length combinations.
| Double Long Port Liposuction Cannula All 13 fittings on one product page |
Double Long Port Liposuction Cannulas The full double long port category |
| Liposuction Cannulas Every port pattern and cannula type we make |
Liposuction Accessories Handles, hubs and cannulas for liposuction |
What is a double long port liposuction cannula used for?
It is used to remove subcutaneous fat under vacuum during liposuction and body contouring. Two long ports each draw along a stretch of shaft, so one pass clears a defined lane rather than a line of spots, at a rate that suits the main working phase of a case rather than bulk debulking or final shaping.
What is the difference between long ports and round holes on a liposuction cannula?
A round hole draws from a point, pulling tissue sideways into a small opening, and the draw surges as each hole blocks and clears. A long port draws along its whole run, so tissue enters as a continuous column in the direction of travel. Long ports clear faster and pull more steadily at the same diameter.
Is this cannula autoclavable?
Yes. The instrument is fully reusable and can be steam autoclaved at 134°C. Flush the lumen and the opening with clean water immediately after use, remove all residue before sterilization, and dry completely. Inspect the opening edge under light at every cycle, since edge condition decides how the cannula behaves in tissue.
Which size should I use?
For body contouring of the abdomen, flanks, back and thighs, 3.0mm to 4.0mm diameters in 25cm to 35cm are the usual range and where this pattern is used most. Arms, neck and refinement work suit 2.0mm to 2.5mm in 15cm to 25cm. Facial and submental contouring uses 1.0mm to 1.5mm in 5cm to 12cm.
What is the minimum order quantity for bulk orders?
The minimum order quantity is agreed per order rather than set at a fixed number. Send us the sizes, fittings and quantities you need through the wholesale request page and we will confirm the minimum for that specification. This lets a small distributor start with a trial order and a larger importer scale up on the same terms.
Do you provide samples?
Yes. Samples are available on request and the buyer covers the shipping charges. Tell us the diameter and length you want to evaluate and we will confirm what can be sent. Handling a sample is the only reliable way to judge whether the grooved grip suits your surgeons.
Can I order a custom size?
Yes. Custom diameters, working lengths and opening dimensions are available on request in addition to the standard size grid. Send your specification through the wholesale request page and our production team will confirm what can be produced. Custom branding is also available for distributor and OEM orders.