Buy Online
Add to Cart Now
Your shopping cart is empty!
Lorem Ipsum is simply dummy text of the printing and typesetting industry.
Globally certified & registered manufacturer
Globally trusted & secured payment methods
Liposuction Cannulas and Accessories › Field Flap Liposuction Cannulas › Field Flap Liposuction Cannula
A field flap liposuction cannula has an elevated leading edge that opens and exposes soft tissue as the cannula advances, allowing more precise suctioning along the mandible and submental areas. The raised edge lifts the plane ahead of the aspiration opening instead of pressing through it. It sits in the Field Flap Liposuction Cannulas category, part of the Healermed Liposuction Cannulas and Accessories range.
Surgeons also search for this instrument as a field flap cannula, an elevated edge liposuction cannula, a jawline liposuction cannula, or a submental contouring cannula.
At a Glance
Along the jawline and under the chin the fat layer is thin and everything is close together. A cannula that cannot open the plane is removing tissue it cannot properly address. An elevated leading edge lifts the tissue first, then suctions what has been exposed.
The working end of this cannula is raised: the leading edge sits proud of the shaft rather than flush with it. That single feature is what separates it from every other aspiration cannula in the range, and it exists because of where the instrument is used.
Along the jawline and under the chin the fat layer is thin and the anatomy is close together. A conventional cannula advances through a plane it cannot open, so the surgeon is suctioning tissue that is lying flat against everything around it and judging the result mostly by feel. An elevated edge lifts the tissue ahead of the opening as the cannula advances, opening the plane and exposing the fat to be removed rather than pressing through it.
Exposure is what gives the precision. With the tissue lifted and held clear of what sits beneath it, the aspiration opening addresses the fat the surgeon intends and not the layer under it. Along the mandibular border, where a few millimetres decides whether the jawline is defined or hollowed, that difference is the whole reason to use this instrument instead of a plain cannula.
The edge is raised but not sharpened. It lifts and separates rather than cutting, so it can work in the superficial submental plane without dividing what it passes. It is also the part that bends: a flattened or deformed edge stops lifting, and once that happens the cannula behaves like an ordinary one and the advantage is gone.
| Luer Lock Standard Luer lock syringes and suction tubing |
Stainless Steel Luer Lock All-steel hub for heavy autoclave cycles |
| Super Luer Lock Larger bore, longer thread, heavier hub |
Threaded Fitting Threaded reusable handles and tubing connectors |
| Fixed Power Handle Integrated handle, permanently attached |
Grooved Power Handle Grooved grip for wet-glove control |
| Black Power Handle Black anodized, low glare under lights |
Toomey Hub 60cc 60cc Toomey-tip syringes, from 2.0mm up |
| MicroAire PAL Compatible MicroAire PAL power-assisted handpieces |
Lumsail Compatible Lumsail machine handpieces |
| Universal Luer Lock Fits Luer lock across syringe brands |
Vibrasat Quick Lock Vibrasat quarter-turn quick-lock coupling |
| BeautiFill Laser Compatible BeautiFill laser lipolysis handpieces |
| Material | German stainless steel |
| Openings | Aspiration opening set behind an elevated leading edge |
| Tip | Elevated leading edge, closed and blunt |
| Diameters | 1.0mm (19G), 1.1mm (19G), 1.2mm (18G), 1.4mm (17G), 1.5mm (17G), 1.6mm (16G), 1.8mm (15G), 2.0mm (14G), 2.4mm (13G), 2.5mm (13G), 3.0mm (11G), 3.5mm (10G), 4.0mm (8G), 4.5mm (7G), 5.0mm (6G), 6.0mm (4G) |
| Lengths | 3, 4, 5, 7, 7.5, 8, 9, 10, 12, 14, 15, 20, 25, 30, 35cm (by diameter) |
| Reusable | Yes — steam autoclavable to 134°C |
| Custom sizes | Available on request |
| Compliance | FDA CGMP, ISO 13485, ISO 9001, CE Mark |
This is a facial and neck instrument, so the fine end of the grid is where it works. The 2.0mm to 3.0mm diameters in 15cm to 25cm cover most jawline and submental contouring. The 1.5mm to 1.8mm diameters in 8cm to 15cm suit finer jowl and perioral work where the layer is thinnest. Larger diameters are available but the elevated edge gives little advantage in deep body planes, where a conventional aspiration cannula is the better choice.
The instrument is made from German stainless steel with a passivated surface that resists corrosion and pitting through repeated cleaning cycles. It is reusable and can be steam autoclaved at 134°C. Clean immediately after use and dry fully before autoclaving. The elevated edge creates a recess that traps tissue against the shaft, so flush from the hub and brush behind the raised edge specifically rather than relying on the lumen alone. Sight along the edge at every cycle: a flattened or bent edge no longer lifts tissue, and cannot be corrected on a reusable instrument.
Buying for your practice? Order online at factory-direct prices, straight from the manufacturer — no distributor markup.
Distributor, importer, or hospital group? Get bulk pricing, OEM manufacturing, and custom branding on the full range.
Manufactured by Healermed Instruments, a surgical instruments manufacturer and exporter based in Sialkot, Pakistan. Factory-direct pricing removes the importer and distributor layer. Production runs under an ISO 13485 and FDA CGMP quality system, with ISO 9001 and CE Mark certification. OEM manufacturing and custom branding are available for distributor and brand-owner orders.
| Field Flap Liposuction Cannulas The full category |
Liposuction Cannulas Every cannula type and port pattern we make |
| Liposuction Accessories Handles, hubs and cannulas for liposuction |
What is a field flap liposuction cannula used for?
It is used to remove subcutaneous fat under vacuum along the mandible and in the submental area. The elevated leading edge opens and exposes the soft tissue as the cannula advances, so the aspiration opening addresses the exposed fat rather than pressing through a closed plane, which is what allows precise contouring where the layer is thin.
What is the difference between a field flap cannula and a standard liposuction cannula?
A standard cannula advances through a plane it does not open, so it suctions tissue lying flat against everything around it. A field flap cannula has an elevated leading edge that lifts and exposes the tissue first, so the opening addresses the fat the surgeon intends. It is built for the jawline and submental area rather than body work.
Is this instrument autoclavable?
Yes. It is fully reusable and can be steam autoclaved at 134°C. Clean immediately after use, remove all residue before sterilization, and dry completely.
Which size should I use?
The 2.0mm to 3.0mm diameters in 15cm to 25cm cover most jawline and submental contouring. Use 1.5mm to 1.8mm in 8cm to 15cm for finer jowl and perioral work where the layer is thinnest. Larger diameters are available, but the elevated edge gives little advantage in deep body planes.
What is the minimum order quantity for bulk orders?
The minimum order quantity is agreed per order rather than set at a fixed number. Send us the sizes, fittings and quantities you need through the wholesale request page and we will confirm the minimum for that specification.
Do you provide samples?
Yes. Samples are available on request and the buyer covers the shipping charges. Tell us the diameter, length and fitting you want to evaluate and we will confirm what can be sent.
Can I order a custom size?
Yes. Custom diameters, working lengths and configurations are available on request in addition to the standard size grid. Send your specification through the wholesale request page and our production team will confirm what can be produced.