Liposuction Cannulas and Accessories › Five Port Crescent Hole Liposuction Cannulas › Five Port Crescent Hole Liposuction Cannula – Grooved Power Handle
The Five Port Crescent Hole Liposuction Cannula with Grooved Power Handle fitting is a five port crescent hole liposuction cannula is a blunt-tip liposuction cannula with five crescent-shaped openings along the shaft, used to remove subcutaneous fat under vacuum during liposuction and body contouring. The curved leading edge of each crescent guides tissue into the port rather than pulling it against a rim, which keeps the draw smooth through fibrous tissue. It is listed under Five Port Crescent Hole Liposuction Cannulas, part of the Healermed Liposuction Cannulas and Accessories range.
Surgeons also search for these liposuction cannulas as crescent hole cannulas, 5 port liposuction cannulas, crescent port lipo cannulas, or scooped port aspiration cannulas.
At a Glance
Grip loss is a practical problem in liposuction, not a cosmetic one. A full case is hundreds of repeated strokes against tissue resistance with wet gloves, and a slipping hand changes the depth and direction of the pass. On a directional cannula the grip also holds the aperture pointing at the layer being worked.
Five openings, each cut as a crescent rather than a circle or a slot. A crescent has one curved leading edge that scoops toward the lumen and a shallower trailing side, so the opening is asymmetric front to back.
That asymmetry is the design. As the liposuction cannula advances, the curved leading edge meets tissue first and guides it inward along the curve rather than presenting a flat wall or a tight circular rim. Fat is led into the port instead of being pulled sideways against an edge, which makes the draw feel smoother through the handle and reduces the grabbing that round holes produce in fibrous tissue.
Five openings is a deliberate middle count. Six or more turn a cannula into a debulking instrument that removes faster than most surgeons want to judge; three or fewer make progress slow across a large area. Five with a scooped profile clears at a working rate while the shaped edges keep each opening from biting, which suits the long middle phase of a case where volume still has to come out but the contour is already forming.
The crescent edges are also what wears. A crescent is a ground profile, and once the leading curve is flattened or nicked it stops guiding tissue and starts dragging it, which is the behaviour the shape exists to avoid. The distal tip is closed and rounded, separating the plane by blunt dissection while the vacuum works through the five crescent openings rather than the end of the shaft.
| Material | German stainless steel |
| Fitting | Grooved grip for wet-glove control |
| Opening | Five crescent-shaped openings along the shaft |
| Tip | Closed blunt tip |
| Diameters | 1.0mm (19G), 1.1mm (19G), 1.2mm (18G), 1.4mm (17G), 1.5mm (17G), 1.6mm (16G), 1.8mm (15G), 2.0mm (14G), 2.4mm (13G), 2.5mm (13G), 3.0mm (11G), 3.5mm (10G), 4.0mm (8G), 4.5mm (7G), 5.0mm (6G), 6.0mm (4G) |
| Lengths | 3, 4, 5, 7, 7.5, 8, 9, 10, 12, 14, 15, 20, 25, 30, 35cm (by diameter) |
| Reusable | Yes — steam autoclavable to 134°C |
| Custom sizes | Available on request |
| Compliance | FDA CGMP, ISO 13485, ISO 9001, CE Mark |
The cannula is made from German stainless steel with a passivated surface that resists corrosion and pitting through repeated cleaning cycles. It is reusable and can be steam autoclaved at 134°C. Flush the lumen and the opening with clean water immediately after use and dry fully before autoclaving. A crescent has a longer perimeter than a round hole of the same width and a scooped recess that holds residue, so flush until the water runs clear and inspect the full curve of all five openings under light at each cycle. A flattened or nicked leading edge drags tissue instead of guiding it and should take the instrument out of service.
Choose the grooved handle for long cases and large surface areas where hand fatigue and grip slip build up; for short refinement work a smooth fixed handle is usually enough. Diameter sets how much fat comes out per pass and length sets the reach. For body contouring of the abdomen, flanks, back and thighs, the 3.0mm to 4.5mm diameters in 25cm to 35cm are the usual working range and where five crescent ports are used most. The 2.0mm to 2.5mm range in 15cm to 25cm covers arms and the neck. For final shaping choose a single-hole or short-hole cannula, which removes far less per pass. Match the fitting to the syringe, vacuum line or handpiece already in your theater.
Buying for your practice? Order online at factory-direct prices, straight from the manufacturer — no distributor markup.
Distributor, importer, or hospital group? Get bulk pricing, OEM manufacturing, and custom branding on the full cannula range.
Manufactured by Healermed Instruments, a surgical instruments manufacturer and exporter based in Sialkot, Pakistan. Factory-direct pricing removes the importer and distributor layer. Production runs under an ISO 13485 and FDA CGMP quality system, with ISO 9001 and CE Mark certification. OEM manufacturing and custom branding are available for distributor and brand-owner orders.
Every fitting below carries the same five port crescent hole shaft, the same closed blunt tip and the same size grid. Pick the one that matches the syringe, vacuum line or handpiece already in your theater.
| Luer Lock Liposuction Cannula Standard Luer lock syringes and suction tubing |
Stainless Steel Luer Lock Liposuction Cannula All-steel hub for heavy autoclave cycles |
| Super Luer Lock Liposuction Cannula Larger bore, longer thread, heavier hub |
Threaded Fitting Liposuction Cannula Threaded reusable handles and tubing connectors |
| Fixed Power Handle Liposuction Cannula Integrated handle, permanently attached |
Black Power Handle Liposuction Cannula Black anodized, low glare under lights |
| Toomey Hub 60cc Liposuction Cannula 60cc Toomey-tip syringes, from 2.0mm up |
MicroAire PAL Compatible Liposuction Cannula MicroAire PAL power-assisted handpieces |
| Lumsail Compatible Liposuction Cannula Lumsail machine handpieces |
Universal Luer Lock Liposuction Cannula Fits Luer lock across syringe brands |
| Vibrasat Quick Lock Liposuction Cannula Vibrasat quarter-turn quick-lock coupling |
BeautiFill Laser Compatible Liposuction Cannula BeautiFill laser lipolysis handpieces |
Healermed manufactures the full range of cannulas for liposuction, from single hole finishing cannulas to high-flow debulking patterns, in 84 diameter and length combinations.
| Five Port Crescent Hole Liposuction Cannula All 13 fittings on one product page |
Five Port Crescent Hole Liposuction Cannulas The full five port crescent hole category |
| Liposuction Cannulas Every port pattern and cannula type we make |
Liposuction Accessories Handles, hubs and cannulas for liposuction |
What is a five port crescent hole liposuction cannula used for?
It is used to remove subcutaneous fat under vacuum during liposuction and body contouring, through the main working phase of a case. Five crescent openings guide tissue inward along their curved leading edges rather than pulling it against a rim, clearing at a working rate while staying smooth in fibrous tissue.
What is the difference between crescent holes and round holes on a liposuction cannula?
A round hole presents a closed circular rim, so fat is pulled sideways against a tight curve and can catch in fibrous tissue. A crescent has a scooped leading edge that guides tissue inward along the curve as the cannula advances, which keeps the draw smoother and reduces grabbing.
Is this cannula autoclavable?
Yes. The instrument is fully reusable and can be steam autoclaved at 134°C. Flush the lumen and the opening with clean water immediately after use, remove all residue before sterilization, and dry completely. Inspect the opening edge under light at every cycle, since edge condition decides how the cannula behaves in tissue.
Which size should I use?
For body contouring of the abdomen, flanks, back and thighs, 3.0mm to 4.5mm diameters in 25cm to 35cm are the usual range and where this pattern is used most. Arms and the neck suit 2.0mm to 2.5mm in 15cm to 25cm. For final shaping a single-hole or short-hole liposuction cannula removes far less per pass and is the better choice.
What is the minimum order quantity for bulk orders?
The minimum order quantity is agreed per order rather than set at a fixed number. Send us the sizes, fittings and quantities you need through the wholesale request page and we will confirm the minimum for that specification. This lets a small distributor start with a trial order and a larger importer scale up on the same terms.
Do you provide samples?
Yes. Samples are available on request and the buyer covers the shipping charges. Tell us the diameter and length you want to evaluate and we will confirm what can be sent. Handling a sample is the only reliable way to judge whether the grooved grip suits your surgeons.
Can I order a custom size?
Yes. Custom diameters, working lengths and opening dimensions are available on request in addition to the standard size grid. Send your specification through the wholesale request page and our production team will confirm what can be produced. Custom branding is also available for distributor and OEM orders.