Buy Online
Add to Cart Now
Your shopping cart is empty!
Lorem Ipsum is simply dummy text of the printing and typesetting industry.
Globally certified & registered manufacturer
Globally trusted & secured payment methods
Liposuction Cannulas and Accessories › Lancet Tip One Central Hole Liposuction Cannulas › Lancet Tip One Central Hole Liposuction Cannula – Toomey Hub 60cc
The Lancet Tip One Central Hole Liposuction Cannula with Toomey Hub 60cc fitting is a lancet tip one central hole liposuction cannula is an aspiration cannula with a pointed, edged lancet tip and a single central opening on the shaft, used to remove subcutaneous fat under vacuum in fibrous and previously operated tissue. The lancet point parts scar that a blunt nose cannot enter, while the single hole keeps removal at one controlled point. It is listed under Lancet Tip One Central Hole Liposuction Cannulas, part of the Healermed Liposuction Cannulas and Accessories range.
Surgeons also refer to these instruments as lancet point cannulas, pointed tip lipo cannulas, spear tip aspiration cannulas, or lancet single hole cannulas.
At a Glance
A Toomey tip is a wide-bore syringe fitting, not a Luer taper. It exists because aspirated fat is thick and moves slowly through a narrow connector. A matching Toomey hub keeps the whole path wide, so the shaft rather than the connector sets the working limit, and the syringe gives the surgeon vacuum they modulate by hand.
A lancet tip is pointed and edged, ground to a narrow leading point rather than closed and domed. It is made to penetrate. Behind it, the shaft carries one central hole, and the pairing of those two features is deliberate: an instrument that gets in easily and then removes very little once it is there.
The tip is the reason to choose this cannula. Scarred and fibrous tissue resists a blunt nose, which either stalls or skips out of the plane and forces the surgeon to push harder than the tissue warrants. A lancet point parts that tissue instead of fighting it, so the cannula reaches an area that a blunt instrument cannot enter in a controlled way.
The single central hole is the counterweight. One opening means removal happens at one known point, at the lowest rate of any pattern we make. That matters here more than on a blunt cannula: an instrument that enters easily should not also remove quickly, or the surgeon gains access and loses control in the same movement.
Because the tip is edged, this cannula asks more of the operator than a blunt one. A lancet point does not distinguish between a fibrous band and a vessel, a nerve or the dermis. It is used in the deep plane, under direct control, with the entry made deliberately rather than by pushing, and it is not run in the superficial layer. The point is also the part that wears: once it is dulled or bent it stops parting tissue and starts pushing it, which is the failure the design exists to avoid.
| Material | German stainless steel |
| Fitting | 60cc Toomey-tip syringes, from 2.0mm up |
| Opening | One central hole on the shaft, behind a lancet tip |
| Tip | Lancet tip — pointed and edged |
| Diameters | 2.0mm (14G), 2.4mm (13G), 2.5mm (13G), 3.0mm (11G), 3.5mm (10G), 4.0mm (8G), 4.5mm (7G), 5.0mm (6G), 6.0mm (4G) |
| Lengths | 3, 5, 7, 10, 12, 14, 15, 20, 25, 30, 35cm (by diameter) |
| Reusable | Yes — steam autoclavable to 134°C |
| Custom sizes | Available on request |
| Compliance | FDA CGMP, ISO 13485, ISO 9001, CE Mark |
The cannula is made from German stainless steel with a passivated surface that resists corrosion and pitting through repeated cleaning cycles. It is reusable and can be steam autoclaved at 134°C. Flush the lumen and the opening with clean water immediately after use and dry fully before autoclaving. Inspect the lancet point under magnification at every cycle. A dulled or bent point stops parting tissue and starts pushing it, which is the behaviour the design exists to avoid, and a bent point cannot be corrected on a reusable instrument. Take any cannula with a damaged point out of service.
The Toomey fitting starts at 2.0mm, so for finer facial work below 2.0mm choose the Luer lock version instead. This is an access and correction instrument, not a contouring one, so size follows the tissue rather than the volume. The 2.0mm to 3.0mm diameters in 15cm to 30cm cover most revision work. The 3.0mm to 3.5mm range in 25cm to 35cm suits larger scarred areas. Whichever size you choose, the lancet point is used in the deep plane, under direct control, and never run in the superficial layer. Match the fitting to the syringe, vacuum line or handpiece already in your theater.
Buying for your practice? Order online at factory-direct prices, straight from the manufacturer — no distributor markup.
Distributor, importer, or hospital group? Get bulk pricing, OEM manufacturing, and custom branding on the full cannula range.
Manufactured by Healermed Instruments, a surgical instruments manufacturer and exporter based in Sialkot, Pakistan. Factory-direct pricing removes the importer and distributor layer. Production runs under an ISO 13485 and FDA CGMP quality system, with ISO 9001 and CE Mark certification. OEM manufacturing and custom branding are available for distributor and brand-owner orders.
Every fitting below carries the same lancet tip one central hole shaft, the same lancet tip and the same size grid. Pick the one that matches the syringe, vacuum line or handpiece already in your theater.
| Luer Lock Liposuction Cannula Standard Luer lock syringes and suction tubing |
Stainless Steel Luer Lock Liposuction Cannula All-steel hub for heavy autoclave cycles |
| Super Luer Lock Liposuction Cannula Larger bore, longer thread, heavier hub |
Threaded Fitting Liposuction Cannula Threaded reusable handles and tubing connectors |
| Fixed Power Handle Liposuction Cannula Integrated handle, permanently attached |
Grooved Power Handle Liposuction Cannula Grooved grip for wet-glove control |
| Black Power Handle Liposuction Cannula Black anodized, low glare under lights |
MicroAire PAL Compatible Liposuction Cannula MicroAire PAL power-assisted handpieces |
| Lumsail Compatible Liposuction Cannula Lumsail machine handpieces |
Universal Luer Lock Liposuction Cannula Fits Luer lock across syringe brands |
| Vibrasat Quick Lock Liposuction Cannula Vibrasat quarter-turn quick-lock coupling |
BeautiFill Laser Compatible Liposuction Cannula BeautiFill laser lipolysis handpieces |
Healermed manufactures the full range of cannulas for liposuction, from single hole finishing cannulas to high-flow debulking patterns, in 84 diameter and length combinations.
| Lancet Tip One Central Hole Liposuction Cannula All 13 fittings on one product page |
Lancet Tip One Central Hole Liposuction Cannulas The full lancet tip one central hole category |
| Liposuction Cannulas Every port pattern and cannula type we make |
Liposuction Accessories Handles, hubs and cannulas for liposuction |
What is a lancet tip one central hole liposuction cannula used for?
It is used to enter fibrous and previously operated tissue and remove subcutaneous fat under vacuum at one controlled point. The lancet point parts scar that a blunt-nose cannula stalls against, while the single central hole keeps removal deliberate once the cannula is in position.
What is the difference between a lancet tip and a blunt tip cannula?
A blunt tip is closed and domed and pushes vessels, nerves and septa aside as it advances. A lancet tip is pointed and edged and parts tissue instead, so it enters scarred and fibrous areas a blunt nose cannot. It demands direct control, stays in the deep plane, and is never run superficially.
Is this cannula autoclavable?
Yes. The instrument is fully reusable and can be steam autoclaved at 134°C. Flush the lumen and the opening with clean water immediately after use, remove all residue before sterilization, and dry completely. Inspect the opening edge under light at every cycle, since edge condition decides how the cannula behaves in tissue.
Which size should I use?
The 2.0mm to 3.0mm diameters in 15cm to 30cm cover most revision and correction work with this pattern. Use 3.0mm to 3.5mm in 25cm to 35cm for larger scarred areas. Size follows the tissue being entered rather than the volume being removed, since this is an access instrument rather than a contouring one.
What is the minimum order quantity for bulk orders?
The minimum order quantity is agreed per order rather than set at a fixed number. Send us the sizes, fittings and quantities you need through the wholesale request page and we will confirm the minimum for that specification. This lets a small distributor start with a trial order and a larger importer scale up on the same terms.
Do you provide samples?
Yes. Samples are available on request and the buyer covers the shipping charges. Tell us the diameter and length you want to evaluate and we will confirm what can be sent. Testing a sample first confirms the hub seats correctly on the 60cc syringes you already stock.
Can I order a custom size?
Yes. Custom diameters, working lengths and opening dimensions are available on request in addition to the standard size grid. Send your specification through the wholesale request page and our production team will confirm what can be produced. Custom branding is also available for distributor and OEM orders.