Buy Online
Add to Cart Now
Your shopping cart is empty!
Lorem Ipsum is simply dummy text of the printing and typesetting industry.
Globally certified & registered manufacturer
Globally trusted & secured payment methods
Liposuction Cannulas and Accessories › Auto Lock Fat Harvesting Syringe 60cc
The Auto Lock Fat Harvesting Syringe 60cc holds negative pressure mechanically as the plunger is drawn, so the surgeon does not have to hold it and no separate stop lock has to be fitted. Body harvesting, where large volumes are collected before processing and plunger force is highest. It is part of the Healermed liposuction cannulas and accessories range.
At a Glance
At 60cc holding the plunger by hand stops being practical. A full draw against a filling barrel generates enough sustained force to tire the hand within a single syringe, and body harvests run through many of them.
Without a mechanical hold the surgeon either accepts vacuum falling away through each syringe or hands the job to an assistant, which means a second person's attention is tied up for the length of the harvest. An integrated lock removes both.
The lock is also working hardest at this size, holding the greatest force in the range. That is why the mechanism wants checking at every sterilization cycle: a lock that creeps on a 60cc syringe loses far more vacuum than one that creeps on a 10cc, and the loss is gradual enough not to be obvious.
In syringe harvesting the vacuum comes from the plunger, and it lasts only as long as something holds the plunger back. On a plain syringe that something is the surgeon's hand.
An auto lock syringe builds the holding into the instrument. As the plunger is drawn back it engages and stays where it was set, so negative pressure is held from the moment the surgeon stops pulling. Nothing has to be clipped on, and nothing has to be held.
The practical difference from a separate stop lock is one fewer part in the sequence. With an add-on lock the surgeon draws back, then fits the lock, then works, then removes the lock to expel. With an auto lock the draw and the hold are the same movement. Over a body harvest running through many syringes that is a meaningful amount of time, and it is one less small stainless part to keep track of, sterilize and lose.
The other gain is consistency. A hand-held plunger creeps as the hand tires, so the last part of a syringe is harvested at lower suction than the first, usually without the surgeon noticing. A mechanical hold does not drift, so every pass into the syringe is taken at the pressure that was set.
| Material | German stainless steel |
| Capacity | 60cc |
| Locking | Integrated auto lock, engages on draw |
| Function | Maintains negative pressure during fat harvesting |
| Reusable | Yes — steam autoclavable to 134°C |
| Other capacities | Also made in the other harvesting sizes |
| Compliance | FDA CGMP, ISO 13485, ISO 9001, CE Mark |
The syringe is made from German stainless steel and is fully reusable, steam autoclavable to 134°C. Dismantle and clean immediately after every case, before fat and tumescent residue set into the barrel and the locking mechanism. Test the lock at every cycle by drawing the plunger back and confirming it holds under load: a mechanism that creeps lets vacuum fall away gradually, which is the one failure on this instrument that gives no outward sign. Take any syringe whose lock no longer holds firmly out of service.
Distributor, importer, or hospital group? Get bulk pricing, OEM manufacturing, and custom branding on the full range.
Manufactured by Healermed Instruments, a surgical instruments manufacturer and exporter based in Sialkot, Pakistan. Factory-direct pricing removes the importer and distributor layer. Production runs under an ISO 13485 and FDA CGMP quality system, with ISO 9001 and CE Mark certification. OEM manufacturing and custom branding are available for distributor and brand-owner orders.
| Auto Lock Fat Harvesting Syringe 10cc Facial and small-volume harvesting, where a few millilitres are taken per pass and the syringe is changed often. |
| Auto Lock Fat Harvesting Syringe 20cc Mid-size harvesting for facial, neck and small body areas, and the usual size for fat grafting preparation. |
| Decanting Stand 60cc to Luer Holds harvest syringes upright for gravity separation before grafting. |
| Luer Lock to Luer Lock Fat Transfer 2mm Low-shear connector for combining harvest syringes and loading injection syringes. |
What is an auto lock fat harvesting syringe?
It is a harvesting syringe with the plunger lock built in. As the plunger is drawn back the lock engages and holds it, so negative pressure is maintained mechanically from the moment the surgeon stops pulling, with nothing to clip on and nothing to hold.
How is it different from a syringe with a separate stop lock?
A separate stop lock has to be fitted after the draw and removed before expelling, on every syringe. With an auto lock the draw and the hold are one movement. It also removes a small stainless part that has to be sterilized and kept track of through the case.
Do I need an auto lock more at 60cc?
Yes. A 60cc plunger drawn fully back against a filling barrel generates enough sustained force to tire the hand within one syringe, and body harvests run through many. Without a mechanical hold you either accept declining vacuum or tie up an assistant to hold it.
Does it hold vacuum better than a hand?
It holds it more consistently. A hand-held plunger creeps as the hand tires, so the last part of a syringe is harvested at lower suction than the first, usually unnoticed. A mechanical hold does not drift.
Is it autoclavable?
Yes. It is German stainless steel and steam autoclavable to 134°C. Dismantle and clean immediately after every case, and test the lock under load at each cycle, since a creeping mechanism lets vacuum fall away with no outward sign.
What is the minimum order quantity for bulk orders?
The minimum order quantity is agreed per order rather than set at a fixed number. Send us the capacities and quantities you need through the wholesale request page and we will confirm the minimum for that specification.