Buy Online
Add to Cart Now
Your shopping cart is empty!
Lorem Ipsum is simply dummy text of the printing and typesetting industry.
Globally certified & registered manufacturer
Globally trusted & secured payment methods
The Standard Single Hole Liposuction Cannula with Fixed Power Handle is a blunt-tip aspiration cannula with one side opening and the handle permanently attached, used to remove subcutaneous fat under vacuum. With no joint between handle and shaft, the hole cannot rotate out of position, there is nothing to loosen mid-case and no leak point in the vacuum path. It is listed under Standard Single Hole Liposuction Cannulas, part of the Healermed Liposuction Cannulas and Accessories range.
Buyers also search for this instrument as a one hole lipo cannula, a single port aspiration cannula, or a standard liposuction cannula.
At a Glance
A fixed handle removes the weakest point of a modular cannula. On a single hole design it also fixes the aperture orientation permanently, so the surgeon always knows which way the opening faces from the shape of the handle alone, without stopping to check. In fine correction work that is one less thing to think about.
One opening means the surgeon knows exactly where the fat is coming from. On a multi-port cannula the draw is spread along the shaft and the result is the sum of several openings working at once; the surgeon aims the instrument and reads the outcome afterwards. With a single hole, the aperture is a known point on a known side, and the removal happens there and nowhere else.
That precision is why the single hole cannula stays in the tray long after faster designs are bought. It is the instrument for the last ten percent of a case: taking down a small ridge, correcting one side that came out fuller than the other, or working a shallow pocket where a wider draw would take too much. It is also the standard teaching instrument, because the relationship between what the hand does and what the tissue does is direct enough to learn from.
The trade is speed. One opening moves less fat per pass than several, so a single hole cannula is the wrong tool for debulking a large area — that is what the multi-port designs are for. Most surgeons carry both and switch when the case moves from volume to refinement.
The distal tip is closed and rounded. It separates the plane by blunt dissection as the cannula advances, pushing vessels and nerves aside rather than dividing them, and the vacuum works through the side hole rather than the end of the shaft.
| Material | German stainless steel |
| Fitting | Fixed power handle, permanently attached |
| Hole | One side opening |
| Tip | Closed blunt tip |
| Diameters | 1.0mm (19G), 1.1mm (19G), 1.2mm (18G), 1.4mm (17G), 1.5mm (17G), 1.6mm (16G), 1.8mm (15G), 2.0mm (14G), 2.4mm (13G), 2.5mm (13G), 3.0mm (11G), 3.5mm (10G), 4.0mm (8G), 4.5mm (7G), 5.0mm (6G), 6.0mm (4G) |
| Lengths | 3, 4, 5, 7, 7.5, 8, 9, 10, 12, 14, 15, 20, 25, 30, 35cm (by diameter) |
| Reusable | Yes — steam autoclavable to 134°C |
| Custom sizes | Available on request |
| Compliance | FDA CGMP, ISO 13485, ISO 9001, CE Mark |
The cannula is made from German stainless steel with a passivated surface that resists corrosion and pitting through repeated cleaning cycles. It is reusable and can be steam autoclaved at 134°C. Flush the lumen and the hole with clean water immediately after use and dry fully before autoclaving. On a single hole cannula the edge of that one opening does all the work, so inspect it under light at each cycle: a nicked or dulled edge changes how the instrument behaves, and there is no second port to compensate.
A fixed handle serves one shaft only, so it suits sizes you use case after case; if you rotate through many diameters, a detachable fitting costs less per size. Diameter sets how much fat comes out per pass and length sets the reach. For general body work the 3.0mm to 4.0mm diameters in 25cm to 35cm are the usual range, though a single hole cannula in those sizes is normally a finishing instrument rather than the one used for bulk removal. The 2.0mm to 2.5mm range in 15cm to 25cm covers arms, the neck and most correction work, which is where this cannula is chosen most often. The 1.0mm to 1.5mm diameters in 5cm to 12cm are for facial and submental work. Match the fitting to the syringe, vacuum line or handpiece already in your theater.
Buying for your practice? Order online at factory-direct prices, straight from the manufacturer — no distributor markup.
Distributor, importer, or hospital group? Get bulk pricing, OEM manufacturing, and custom branding on the full cannula range.
Manufactured by Healermed Instruments, a surgical instruments manufacturer and exporter based in Sialkot, Pakistan. Factory-direct pricing removes the importer and distributor layer. Production runs under an ISO 13485 and FDA CGMP quality system, with ISO 9001 and CE Mark certification. OEM manufacturing and custom branding are available for distributor and brand-owner orders.
Other fittings in the same cannula range:
What is a fixed handle single hole cannula used for?
It is used to remove subcutaneous fat under vacuum from one known point, with the handle permanently joined to the shaft. Surgeons choose it for routine sizes where they want maximum rigidity, no vacuum leak at a joint, and an aperture orientation they can read from the handle alone.
What is the difference between a single hole and a multi-port liposuction cannula?
A single hole cannula has one opening and removes fat from one known point; a multi-port cannula has several and clears volume faster from a wider area. Single hole suits precision work, small corrections and teaching. Multi-port suits debulking large areas where speed matters more than pinpoint control.
Is this cannula autoclavable?
Yes. The instrument is fully reusable and can be steam autoclaved at 134°C. Flush the lumen and the hole with clean water immediately after use, remove all residue before sterilization, and dry completely. Inspect the hole edge each cycle, since on a single hole cannula that one edge determines how the instrument performs.
What is the minimum order quantity for bulk orders?
The minimum order quantity is agreed per order rather than set at a fixed number. Send us the sizes, fittings and quantities you need through the wholesale request page and we will confirm the minimum for that specification. This lets a small distributor start with a trial order and a larger importer scale up on the same terms.
Do you provide samples?
Yes. Samples are available on request and the buyer covers the shipping charges. Tell us the diameter and length you want to evaluate and we will confirm what can be sent. Handling a sample is the only reliable way to judge handle balance before committing to a bulk order.
Can I order a custom size?
Yes. Custom diameters, working lengths and hole positions are available on request in addition to the standard size grid. Send your specification through the wholesale request page and our production team will confirm what can be produced. Custom branding is also available for distributor and OEM orders.