The Mercedes Tip Liposuction Cannula is a blunt-tip aspiration cannula with three ports set around the shaft at about 120 degrees apart, used to remove subcutaneous fat under vacuum during liposuction and body contouring. It is the most widely used aspiration pattern in body contouring and the size most surgeons order first is 3.0mm x 30cm. It sits in the Mercedes Tip Liposuction Cannulas category, part of the wider Healermed Liposuction Cannulas and Accessories range, and is supplied in 11 hub and handle fittings and 84 diameter and length combinations worldwide.
Surgeons also refer to these instruments as Mercedes cannulas, three port liposuction cannulas, 3 hole Mercedes cannulas, or tri-port aspiration cannulas.
At a Glance
If a theatre stocks one liposuction cannula pattern, it is this one. The Mercedes tip is the general-purpose aspiration cannula: fast enough to clear a large area, controlled enough to stay in the plane, and predictable enough that a surgeon can move between sizes without relearning how the instrument behaves.
A Mercedes tip cannula has three ports set around the circumference of the shaft near the distal end, spaced evenly at about 120 degrees apart. The name comes from the resemblance to the three-pointed star: three openings radiating from a single point on the shaft. It is the most widely used aspiration port pattern in body contouring, and for most surgeons it is the default cannula the case starts with.
The reason it became the standard is the balance between speed and control. Three ports move considerably more fat per pass than one, so a large area is cleared in reasonable time. Because they sit around the shaft rather than strung along it, the working aperture stays short: removal happens in a defined band near the tip rather than over a long stretch, so the surgeon can still judge how much has come out of any one area.
The radial spacing does something a surgeon feels directly. With ports on one side only, vacuum pulls the cannula toward that side and the hand has to correct for it. With three ports at 120 degrees the load is symmetrical, so the cannula tracks straight and the tunnel it leaves is even. That is what makes the Mercedes pattern forgiving over long passes and in fibrous tissue.
The distal tip is closed and rounded. It separates the plane by blunt dissection as the cannula advances, pushing vessels and nerves aside rather than dividing them, and the vacuum works through the three side ports rather than the end of the shaft.
| Fitting | Connects to |
| Luer Lock | Standard Luer lock syringes and suction tubing |
| Stainless Steel Luer Lock | Same as Luer lock, all-steel hub for heavy autoclave cycles |
| Super Luer Lock | Luer connection with a larger bore, longer thread and heavier hub |
| Threaded Fitting | Threaded reusable handles and tubing connectors |
| Fixed Power Handle | Integrated handle, permanently attached to the shaft |
| Grooved Power Handle | Grooved grip handle for controlled passes |
| Black Power Handle | Black anodized handle, reduced glare under operating lights |
| Toomey Hub, 60cc | 60cc Toomey-tip syringes, available from 2.0mm upward |
| MicroAire PAL Compatible | MicroAire PAL power-assisted handpieces |
| Lumsail Compatible | Lumsail machine handpieces |
| Universal Luer Lock | Luer lock hub built to fit across syringe brands |
| Material | German stainless steel |
| Port pattern | Mercedes — three ports at about 120 degrees around the shaft |
| Tip | Closed blunt tip |
| Diameters | 1.0mm (19G), 1.1mm (19G), 1.2mm (18G), 1.4mm (17G), 1.5mm (17G), 1.6mm (16G), 1.8mm (15G), 2.0mm (14G), 2.4mm (13G), 2.5mm (13G), 3.0mm (11G), 3.5mm (10G), 4.0mm (8G), 4.5mm (7G), 5.0mm (6G), 6.0mm (4G) |
| Lengths | 3, 4, 5, 7, 7.5, 8, 9, 10, 12, 14, 15, 20, 25, 30, 35cm (by diameter) |
| Fittings | 11 hub and handle types |
| Reusable | Yes — steam autoclavable to 134°C |
| Custom sizes | Available on request |
| Compliance | FDA CGMP, ISO 13485, ISO 9001, CE Mark |
The cannula is made from German stainless steel with a passivated surface that resists corrosion and pitting through repeated cleaning cycles. It is reusable and can be steam autoclaved at 134°C. Flush the lumen and all three ports with clean water immediately after use and dry fully before autoclaving. Check each port under light at each cycle: the Mercedes pattern only tracks straight while all three draw evenly, and one partly blocked port pulls the cannula off line.
3.0mm in 25cm to 35cm is the size most surgeons order first and covers most abdomen and flank work. Step up to 3.5mm or 4.0mm where volume is higher, or to 4.5mm to 6.0mm for large-volume cases and deep-layer work. Drop to 2.0mm to 2.5mm in 15cm to 25cm for arms, neck and superficial refinement, and to 1.0mm to 1.5mm in 5cm to 12cm for facial and submental contouring. Match the fitting to the syringe, vacuum line or handpiece already in your theater.
Buying for your practice? Order online at factory-direct prices, straight from the manufacturer — no distributor markup.
Distributor, importer, or hospital group? Get bulk pricing, OEM manufacturing, and custom branding on the full cannula range.
Manufactured by Healermed Instruments, a surgical instruments manufacturer and exporter based in Sialkot, Pakistan. Factory-direct pricing removes the importer and distributor layer. Production runs under an ISO 13485 and FDA CGMP quality system, with ISO 9001 and CE Mark certification. OEM manufacturing and custom branding are available for distributor and brand-owner orders.
Choose the fitting that matches your equipment:
What is a Mercedes tip cannula used for?
It is used to remove subcutaneous fat under vacuum during liposuction and body contouring. Three ports set at about 120 degrees around the shaft clear fat quickly while keeping the aperture short, and the symmetrical vacuum load lets the cannula track straight through long passes. It is the standard general-purpose liposuction cannula.
What size Mercedes cannula should I use?
3.0mm in 25cm to 35cm is the most-ordered size and covers most abdomen and flank work. Move to 3.5mm or 4.0mm for higher-volume debulking of the abdomen, back and thighs. Use 2.0mm to 2.5mm in 15cm to 25cm for arms, neck and superficial refinement, and 1.0mm to 1.5mm for facial work.
Is a Mercedes cannula autoclavable?
Yes. The instrument is fully reusable and can be steam autoclaved at 134°C. Flush the lumen and all three ports with clean water immediately after use, remove all residue before sterilization, and dry completely. Inspect every port each cycle, since the pattern depends on all three drawing evenly to track straight.
What is the minimum order quantity for bulk orders?
The minimum order quantity is agreed per order rather than set at a fixed number. Send us the sizes, fittings and quantities you need through the wholesale request page and we will confirm the minimum for that specification. This lets a small distributor start with a trial order and a larger importer scale up on the same terms.
What is the difference between a Mercedes tip and a single hole cannula?
A Mercedes tip has three ports around the shaft and clears fat several times faster; a single hole cannula has one opening and removes from one point. Mercedes is the general-purpose cannula for the body of the case. Single hole is the finishing instrument for small corrections at the end.
Do you provide samples?
Yes. Samples are available on request and the buyer covers the shipping charges. Tell us the diameter, length and fitting you want to evaluate and we will confirm what can be sent. Testing a sample before a bulk order is the fastest way to check port edge finish and hub fit against your own equipment.
Can I order a custom size?
Yes. Custom diameters, working lengths and port configurations are available on request in addition to the standard size grid. Send your specification through the wholesale request page and our production team will confirm what can be produced. Custom branding is also available for distributor and OEM orders.