Shop by Instrument Type

Shop by Instrument Type

We use cookies 🍪
We use cookies and other similar technologies to improve your browsing experience and the functionality of our site. Learn more in our GDPR & Privacy Policy.

Central and Two Parallel Ports Cannula – Luer Lock

One Central Port Two Parallel Ports liposuction cannula with Luer Lock hub, German stainless steel
One Central Port Two Parallel Ports liposuction cannula with Luer Lock hub, German stainless steel
One Central Port Two Parallel Ports liposuction cannula with Luer Lock hub, German stainless steel
One Central Port Two Parallel Ports liposuction cannula with Luer Lock hub, German stainless steel
Central and Two Parallel Ports Cannula – Luer Lock
Liposuction Cannulas and Accessories › One Central Port Two Parallel Ports Liposuction Cannulas › One Central Port Two Parallel Ports Liposuction Cannula – Luer Lock The One Central Port Two Parallel Ports Liposuction Cannula with Luer Lock fittin... Read More
$12.00

Available Options

Direct Manufacturer B2B / OEM

Buy Online

Add to Cart Now

Bulk & Wholesale

Volume pricing & private label

Factory Quote

Logo & Name Engraving

FREE

Add your logo or name in checkout notes

Guide

Custom Sizes

Any length, curvature, or modification — to your spec

Request

Certified Quality

Globally certified & registered manufacturer

  • FDA · cGMPUS Registered & GMP Compliant
  • CE MarkingEU MDR Compliant
  • ISO 13485Medical Devices QMS
  • ISO 9001Quality Management
  • EUDAMEDEU Registered
SSL SECURED

Your Security, Our Priority

Globally trusted & secured payment methods

  • PayPal
  • Visa / Mastercard
  • Apple Pay
  • Google Pay
  • Bank transfer

Liposuction Cannulas and AccessoriesOne Central Port Two Parallel Ports Liposuction CannulasOne Central Port Two Parallel Ports Liposuction Cannula – Luer Lock

The One Central Port Two Parallel Ports Liposuction Cannula with Luer Lock fitting is a one central port two parallel ports liposuction cannula is a blunt-tip aspiration cannula with three grouped openings: one central port above and two parallel ports below it. It is listed under One Central Port Two Parallel Ports Liposuction Cannulas, part of the Healermed Liposuction Cannulas and Accessories range.

Surgeons also refer to these instruments as central port cannulas, grouped three port lipo cannulas, triangular port aspiration cannulas, or one-above-two port cannulas.

At a Glance

  • Instrument type: One Central Port Two Parallel Ports liposuction aspiration cannula, reusable
  • Fitting: Standard Luer lock syringes and suction tubing
  • Opening: One central port with two parallel ports set below it
  • Tip: Closed blunt tip
  • Diameters: 1.0mm (19G) to 6.0mm (4G)
  • Working lengths: 3cm to 35cm
  • Material: German stainless steel
  • Sterilization: Steam autoclavable to 134°C
  • Manufacturer: Healermed Instruments, Sialkot, Pakistan

One Central Port Two Parallel Ports Liposuction Cannula — Luer Lock

The Luer lock is the most common connection in aesthetic surgery. A threaded collar screws onto the syringe or tubing set and holds the joint closed under vacuum, where a slip fit can pull apart. In syringe-assisted liposuction that matters, because a disconnection breaks the vacuum and interrupts the pass.

How the Central and Parallel Ports Work Together

Three openings arranged as a set rather than a row: one central port sits above, and two parallel ports sit below it on either side. The three together form a compact triangular group on a short stretch of shaft.

The central port is the aiming point. It is the opening the surgeon lines up with the layer being treated, and because it sits alone at the top it gives a clear reference for how the cannula is oriented. Rotate the shaft and the whole group turns with it, so the plane is chosen deliberately rather than left to how the instrument happens to sit.

The two parallel ports below add draw without spreading the aperture. Three openings in a row along the shaft would stretch the working area over a long stretch and make it harder to judge how much has come out of any one place. Grouping them instead keeps removal concentrated where the surgeon is looking, at roughly three times the rate of a single hole.

The arrangement also steadies the pass. With the load shared across three points instead of pulled through one, the cannula tracks straighter and is less inclined to dig at the opening. That is what puts this pattern in the middle of a case: enough removal to make progress across an area, enough control to stop where the contour is right. The distal tip is closed and rounded, separating the plane by blunt dissection while the vacuum works through the three ports rather than the end of the shaft.

Key Features

  • Threaded Luer lock hub fits standard Luer lock syringes and suction tubing
  • One central port acts as the aiming reference for the whole group
  • Two parallel ports below add draw without spreading the working aperture
  • Roughly three times the removal of a single hole, kept in a compact area
  • Load shared across three points, so the cannula tracks straighter
  • Closed blunt tip separates the plane without cutting vessels or nerves
  • One-piece German stainless steel shaft, fully reusable
  • Custom diameters, lengths and port spacing available on request

Specifications

MaterialGerman stainless steel
FittingStandard Luer lock syringes and suction tubing
OpeningOne central port with two parallel ports set below it
TipClosed blunt tip
Diameters1.0mm (19G), 1.1mm (19G), 1.2mm (18G), 1.4mm (17G), 1.5mm (17G), 1.6mm (16G), 1.8mm (15G), 2.0mm (14G), 2.4mm (13G), 2.5mm (13G), 3.0mm (11G), 3.5mm (10G), 4.0mm (8G), 4.5mm (7G), 5.0mm (6G), 6.0mm (4G)
Lengths3, 4, 5, 7, 7.5, 8, 9, 10, 12, 14, 15, 20, 25, 30, 35cm (by diameter)
ReusableYes — steam autoclavable to 134°C
Custom sizesAvailable on request
ComplianceFDA CGMP, ISO 13485, ISO 9001, CE Mark

Clinical Applications

  • Mid-stage body contouring between debulking and final refinement
  • Layer-specific work where the surgeon rotates the group to choose the plane
  • Abdomen, flanks and thighs with the 3.0mm to 4.0mm diameters
  • Arm, neck and submental work with the 2.0mm to 2.5mm diameters

Material and Sterilization

The cannula is made from German stainless steel with a passivated surface that resists corrosion and pitting through repeated cleaning cycles. It is reusable and can be steam autoclaved at 134°C. Flush the lumen and the opening with clean water immediately after use and dry fully before autoclaving. The three ports sit close together, which makes it easy to flush past one without clearing it, so turn the cannula while flushing and confirm water runs from each of the three before drying. Check all three edges under light at every cycle, since the pattern only tracks straight while all three draw evenly.

How to Choose

Diameter sets how much fat comes out per pass and length sets the reach. For body contouring of the abdomen, flanks and thighs, the 3.0mm to 4.0mm diameters in 25cm to 35cm are the usual working range and where this pattern is used most. The 2.0mm to 2.5mm range in 15cm to 25cm covers arms, the neck and refinement work. The 1.0mm to 1.5mm diameters in 5cm to 12cm are for facial and submental contouring. Match the fitting to the syringe, vacuum line or handpiece already in your theater.

Buying for your practice? Order online at factory-direct prices, straight from the manufacturer — no distributor markup.

Shop Online

Distributor, importer, or hospital group? Get bulk pricing, OEM manufacturing, and custom branding on the full cannula range.

Request Wholesale Price

Why Buy Direct From the Manufacturer

Manufactured by Healermed Instruments, a surgical instruments manufacturer and exporter based in Sialkot, Pakistan. Factory-direct pricing removes the importer and distributor layer. Production runs under an ISO 13485 and FDA CGMP quality system, with ISO 9001 and CE Mark certification. OEM manufacturing and custom branding are available for distributor and brand-owner orders.

Choose Your Fitting

Every fitting below carries the same one central port two parallel ports shaft, the same closed blunt tip and the same size grid. Pick the one that matches the syringe, vacuum line or handpiece already in your theater.

Stainless Steel Luer Lock Liposuction Cannula
All-steel hub for heavy autoclave cycles
Super Luer Lock Liposuction Cannula
Larger bore, longer thread, heavier hub
Threaded Fitting Liposuction Cannula
Threaded reusable handles and tubing connectors
Fixed Power Handle Liposuction Cannula
Integrated handle, permanently attached
Grooved Power Handle Liposuction Cannula
Grooved grip for wet-glove control
Black Power Handle Liposuction Cannula
Black anodized, low glare under lights
Toomey Hub 60cc Liposuction Cannula
60cc Toomey-tip syringes, from 2.0mm up
MicroAire PAL Compatible Liposuction Cannula
MicroAire PAL power-assisted handpieces
Lumsail Compatible Liposuction Cannula
Lumsail machine handpieces
Universal Luer Lock Liposuction Cannula
Fits Luer lock across syringe brands
Vibrasat Quick Lock Liposuction Cannula
Vibrasat quarter-turn quick-lock coupling
BeautiFill Laser Compatible Liposuction Cannula
BeautiFill laser lipolysis handpieces

More Liposuction Cannulas and Accessories

Healermed manufactures the full range of cannulas for liposuction, from single hole finishing cannulas to high-flow debulking patterns, in 84 diameter and length combinations.

One Central Port Two Parallel Ports Liposuction Cannula
All 13 fittings on one product page
One Central Port Two Parallel Ports Liposuction Cannulas
The full one central port two parallel ports category
Liposuction Cannulas
Every port pattern and cannula type we make
Liposuction Accessories
Handles, hubs and cannulas for liposuction

Frequently Asked Questions

What is a one central port two parallel ports liposuction cannula used for?

It is used to remove subcutaneous fat under vacuum during liposuction and body contouring. One central port with two parallel ports below gives roughly three times the removal of a single hole while keeping the working aperture compact, which suits mid-stage contouring where volume and control both matter.

What is the difference between grouped ports and three ports in a row?

Three ports in a row stretch the working aperture along the shaft, so one pass draws from a long strip and it is harder to judge how much came from any one place. Grouping them keeps the aperture short and the removal concentrated where the surgeon is looking, with the central port as an aiming reference.

Is this cannula autoclavable?

Yes. The instrument is fully reusable and can be steam autoclaved at 134°C. Flush the lumen and the opening with clean water immediately after use, remove all residue before sterilization, and dry completely. Inspect the opening edge under light at every cycle, since edge condition decides how the cannula behaves in tissue.

Which size should I use?

For body contouring of the abdomen, flanks and thighs, 3.0mm to 4.0mm diameters in 25cm to 35cm are the usual range and where this pattern is used most. Arms, neck and refinement work suit 2.0mm to 2.5mm in 15cm to 25cm. Facial and submental contouring uses 1.0mm to 1.5mm in 5cm to 12cm.

What is the minimum order quantity for bulk orders?

The minimum order quantity is agreed per order rather than set at a fixed number. Send us the sizes, fittings and quantities you need through the wholesale request page and we will confirm the minimum for that specification. This lets a small distributor start with a trial order and a larger importer scale up on the same terms.

Do you provide samples?

Yes. Samples are available on request and the buyer covers the shipping charges. Tell us the diameter and length you want to evaluate and we will confirm what can be sent. Testing a sample first is the fastest way to check edge finish and hub fit against your own syringes.

Can I order a custom size?

Yes. Custom diameters, working lengths and opening dimensions are available on request in addition to the standard size grid. Send your specification through the wholesale request page and our production team will confirm what can be produced. Custom branding is also available for distributor and OEM orders.

Brand: Healermed instruments Model: HM-WLT-6
The Walter Osteotome in the 6mm straight fine pattern is a mallet-driven bone cutting instrument used to divide and contour bone in oral, maxillofacia..
$12.00
Add to Cart
Brand: Healermed instruments Model: HM-BSK-GPH
Liposuction Cannulas and Accessories › Basket Liposuction Cannulas › Basket Liposuction Cannula – Grooved Power Handle The Basket Sha..
$25.00
Add to Cart
Brand: Healermed instruments Model: HM-ENTS-18
ENT micro instruments are the fine, single-ended hand tools used in ear, nose and throat surgery, where the working area is only a few millimetres wid..
$165.00
Add to Cart
Brand: Healermed instruments Model: HM-DSD-ULL
Liposuction Cannulas and Accessories › Deep Sharp Cut Dissector Liposuction Cannulas › Deep Sharp Cut Dissector Liposuction Cannula – Un..
$8.00
Add to Cart
Brand: Healermed instruments Model: HMI-DNP-01
The Davis Nasal Projectometer is a reusable stainless steel measuring instrument used in rhinoplasty to measure nasal projection, dorsal height and th..
$195.00
Add to Cart
Brand: Healermed instruments Model: HM-WLT-2
The Walter Osteotome is a fine, straight surgical osteotome used for precise cutting and shaping of bone in oral, maxillofacial, and other small-bone ..
$12.00
Add to Cart
Brand: Healermed instruments Model: HM-2SQ-MA
Liposuction Cannulas and Accessories › Two Square Ports In Line Liposuction Cannulas › Two Square Ports In Line Liposuction Cannula – Mi..
$45.00
Add to Cart
Brand: Healermed instruments Model: HM-MRC-LC
The Lumsail Compatible Mercedes Tip Liposuction Cannula is a blunt-tip aspiration cannula with three ports around the shaft, fitted with a hub machine..
$15.00
Add to Cart
Healermed Support
Sales Agent · Online

Chat on WhatsApp
Only $650 to free shipping · $55 flat worldwide · Track order →