The Mercedes Tip Liposuction Cannula with BeautiFill Laser Compatible fitting carries the same shaft, openings and tip as every other fitting in the range, with a hub built for that equipment. It is part of the Healermed liposuction cannulas and accessories range.
At a Glance
Laser-assisted lipolysis systems deliver laser energy through the cannula as well as drawing fat through it, so the hub has to seat into the handpiece with the fibre path aligned and held. That is a tighter mechanical requirement than a syringe fitting: play at the coupling affects alignment, not just vacuum. A cannula for this kind of system is machined to the handpiece rather than to a general standard, which is why it fits that equipment and nothing else.
A Mercedes tip cannula has three ports set around the circumference of the shaft near the distal end, spaced evenly at about 120 degrees apart. The name comes from the resemblance to the three-pointed star: three openings radiating from a single point on the shaft. It is the most widely used aspiration port pattern in body contouring, and for most surgeons it is the default cannula the case starts with.
The reason it became the standard is the balance between speed and control. Three ports move considerably more fat per pass than one, so a large area is cleared in reasonable time. Because they sit around the shaft rather than strung along it, the working aperture stays short: removal happens in a defined band near the tip rather than over a long stretch, so the surgeon can still judge how much has come out of any one area.
The radial spacing does something a surgeon feels directly. With ports on one side only, vacuum pulls the cannula toward that side and the hand has to correct for it. With three ports at 120 degrees the load is symmetrical, so the cannula tracks straight and the tunnel it leaves is even. That is what makes the Mercedes pattern forgiving over long passes and in fibrous tissue.
The distal tip is closed and rounded. It separates the plane by blunt dissection as the cannula advances, pushing vessels and nerves aside rather than dividing them, and the vacuum works through the three side ports rather than the end of the shaft.
| Material | German stainless steel |
| Fitting | Hub machined to fit BeautiFill laser handpieces |
| Openings | Three, set at about 120 degrees around the shaft |
| Tip | Closed blunt tip |
| Diameters | 1.0mm (19G), 1.1mm (19G), 1.2mm (18G), 1.4mm (17G), 1.5mm (17G), 1.6mm (16G), 1.8mm (15G), 2.0mm (14G), 2.4mm (13G), 2.5mm (13G), 3.0mm (11G), 3.5mm (10G), 4.0mm (8G), 4.5mm (7G), 5.0mm (6G), 6.0mm (4G) |
| Lengths | 3, 4, 5, 7, 7.5, 8, 9, 10, 12, 14, 15, 20, 25, 30, 35cm (by diameter) |
| Reusable | Yes — steam autoclavable to 134°C |
| Compliance | FDA CGMP, ISO 13485, ISO 9001, CE Mark |
The cannula is made from German stainless steel with a passivated surface that resists corrosion through repeated cleaning cycles. It is reusable and steam autoclavable to 134°C. Flush the lumen and every opening immediately after use, remove all residue before sterilization, and dry completely. Inspect the hub coupling as well as the openings at each cycle, since a worn coupling loses the seal and the alignment the equipment depends on.
Order this fitting only if you own a BeautiFill laser system, and confirm the handpiece model with us before ordering; the hub will not fit a syringe or a manual handle. The size grid is identical across every fitting in this range.
Buy online |
Distributor, importer, or hospital group? Get bulk pricing, OEM manufacturing, and custom branding on the full range. |
Trademark notice: BeautiFill is a trademark of Alma Lasers Ltd. Healermed Instruments is not affiliated with, endorsed by, or sponsored by Alma Lasers. This cannula is an independently manufactured instrument and the compatibility reference is provided for the buyer's guidance only. Confirm compatibility with your own handpiece before ordering.
The same mercedes tip cannula is made in every fitting below. Pick the one that matches the syringe, vacuum line or handpiece already in your theater.
| Luer Lock Standard Luer lock syringes and suction tubing |
| Stainless Steel Luer Lock All-steel hub for heavy autoclave cycles |
| Super Luer Lock Larger bore, longer thread, heavier hub |
| Threaded Fitting Threaded reusable handles and connectors |
| Fixed Power Handle Integrated handle, permanently attached |
| Grooved Power Handle Grooved grip for wet-glove control |
| Black Power Handle Black anodized, low glare under lights |
| Toomey Hub 60cc 60cc Toomey-tip syringes |
| MicroAire PAL Compatible MicroAire PAL power-assisted handpieces |
| Lumsail Compatible Lumsail machine handpieces |
| Universal Luer Lock Fits Luer lock across syringe brands |
| Vibrasat Quick Lock Vibrasat power-assisted handpieces with quick-lock coupling |
| Mercedes Tip Liposuction Cannula All fittings on one product page |
Manufactured by Healermed Instruments, a surgical instruments manufacturer and exporter based in Sialkot, Pakistan. Factory-direct pricing removes the importer and distributor layer. Production runs under an ISO 13485 and FDA CGMP quality system, with ISO 9001 and CE Mark certification. OEM manufacturing and custom branding are available for distributor and brand-owner orders.
What is a mercedes tip beautifill laser compatible cannula used for?
It is used with BeautiFill laser lipolysis handpieces during laser-assisted liposuction and fat harvesting. The hub is machined to seat into that handpiece specifically; the shaft, openings and tip work as they do on the manual versions of the same cannula.
Does this fit any other handpiece?
No. Handpiece manufacturers do not share a common fitting, so a hub machined for one system will not seat correctly in another. Adapting or forcing a fitting introduces play at the point that carries mechanical load and holds the seal. Order the hub that matches your equipment.
Is this cannula autoclavable?
Yes. It is fully reusable and steam autoclavable to 134°C. Flush the lumen and every opening immediately after use, and inspect the hub coupling at each cycle.
Do you provide samples?
Yes. Samples are available on request and the buyer covers the shipping charges. Send us your handpiece and system details with the diameter and length you want to evaluate, and confirm compatibility with us before ordering. Testing a sample in your own handpiece before a bulk order is essential for any laser system fitting.
What is the minimum order quantity for bulk orders?
The minimum order quantity is agreed per order rather than set at a fixed number. Send us the sizes, fittings and quantities you need through the wholesale request page and we will confirm the minimum for that specification.