The Standard Single Hole Liposuction Cannula with Toomey Hub is a blunt-tip aspiration cannula with one side opening, built to fit 60cc Toomey-tip syringes for syringe-assisted liposuction and fat harvesting. The wide, non-Luer Toomey opening lets aspirated fat move without the resistance a narrow taper creates. This fitting is made from 2.0mm (14G) upward. It is listed under Standard Single Hole Liposuction Cannulas, part of the Healermed Liposuction Cannulas and Accessories range.
Buyers also search for this instrument as a 60cc Toomey single hole cannula, a syringe liposuction cannula, or a one hole fat harvesting cannula.
At a Glance
A Toomey tip is a wide-bore syringe fitting, not a Luer taper. Combined with a single hole shaft it gives a controlled, hand-driven draw: the syringe supplies gentle vacuum the surgeon can modulate directly, and one opening keeps the removal exactly where it is aimed. That combination is common in fat harvesting and in small-volume correction work.
One opening means the surgeon knows exactly where the fat is coming from. On a multi-port cannula the draw is spread along the shaft and the result is the sum of several openings working at once; the surgeon aims the instrument and reads the outcome afterwards. With a single hole, the aperture is a known point on a known side, and the removal happens there and nowhere else.
That precision is why the single hole cannula stays in the tray long after faster designs are bought. It is the instrument for the last ten percent of a case: taking down a small ridge, correcting one side that came out fuller than the other, or working a shallow pocket where a wider draw would take too much. It is also the standard teaching instrument, because the relationship between what the hand does and what the tissue does is direct enough to learn from.
The trade is speed. One opening moves less fat per pass than several, so a single hole cannula is the wrong tool for debulking a large area — that is what the multi-port designs are for. Most surgeons carry both and switch when the case moves from volume to refinement.
The distal tip is closed and rounded. It separates the plane by blunt dissection as the cannula advances, pushing vessels and nerves aside rather than dividing them, and the vacuum works through the side hole rather than the end of the shaft.
| Material | German stainless steel |
| Fitting | Toomey hub, 60cc syringes |
| Hole | One side opening |
| Tip | Closed blunt tip |
| Diameters | 2.0mm (14G), 2.4mm (13G), 2.5mm (13G), 3.0mm (11G), 3.5mm (10G), 4.0mm (8G), 4.5mm (7G), 5.0mm (6G), 6.0mm (4G) |
| Lengths | 3, 5, 7, 10, 12, 14, 15, 20, 25, 30, 35cm (by diameter) |
| Reusable | Yes — steam autoclavable to 134°C |
| Custom sizes | Available on request |
| Compliance | FDA CGMP, ISO 13485, ISO 9001, CE Mark |
The cannula is made from German stainless steel with a passivated surface that resists corrosion and pitting through repeated cleaning cycles. It is reusable and can be steam autoclaved at 134°C. Flush the lumen and the hole with clean water immediately after use and dry fully before autoclaving. On a single hole cannula the edge of that one opening does all the work, so inspect it under light at each cycle: a nicked or dulled edge changes how the instrument behaves, and there is no second port to compensate.
The Toomey fitting starts at 2.0mm, so for finer facial work below 2.0mm choose the Luer lock version instead. Within the Toomey range, 2.0mm to 2.5mm in 15cm to 25cm covers arms, neck and most correction work, while 3.0mm to 4.0mm in 25cm to 35cm is for larger areas.
Buying for your practice? Order online at factory-direct prices, straight from the manufacturer — no distributor markup.
Distributor, importer, or hospital group? Get bulk pricing, OEM manufacturing, and custom branding on the full cannula range.
Manufactured by Healermed Instruments, a surgical instruments manufacturer and exporter based in Sialkot, Pakistan. Factory-direct pricing removes the importer and distributor layer. Production runs under an ISO 13485 and FDA CGMP quality system, with ISO 9001 and CE Mark certification. OEM manufacturing and custom branding are available for distributor and brand-owner orders.
Other fittings in the same cannula range:
What is a Toomey hub single hole cannula used for?
It is used with 60cc Toomey-tip syringes for syringe-assisted liposuction, small-volume correction and fat harvesting. The syringe gives vacuum the surgeon modulates by hand, and the single opening keeps removal exactly where it is aimed rather than spread along the shaft.
What is the difference between a single hole and a multi-port liposuction cannula?
A single hole cannula has one opening and removes fat from one known point; a multi-port cannula has several and clears volume faster from a wider area. Single hole suits precision work, small corrections and teaching. Multi-port suits debulking large areas where speed matters more than pinpoint control.
Is this cannula autoclavable?
Yes. The instrument is fully reusable and can be steam autoclaved at 134°C. Flush the lumen and the hole with clean water immediately after use, remove all residue before sterilization, and dry completely. Inspect the hole edge each cycle, since on a single hole cannula that one edge determines how the instrument performs.
What is the minimum order quantity for bulk orders?
The minimum order quantity is agreed per order rather than set at a fixed number. Send us the sizes, fittings and quantities you need through the wholesale request page and we will confirm the minimum for that specification. This lets a small distributor start with a trial order and a larger importer scale up on the same terms.
Do you provide samples?
Yes. Samples are available on request and the buyer covers the shipping charges. Tell us the diameter and length you want to evaluate and we will confirm what can be sent. Testing a sample first confirms the hub seats correctly on the 60cc syringes you already stock.
Can I order a custom size?
Yes. Custom diameters, working lengths and hole positions are available on request in addition to the standard size grid. Send your specification through the wholesale request page and our production team will confirm what can be produced. Custom branding is also available for distributor and OEM orders.